Article

TRANSFUSIÓN EN NEONATOLOGÍA

Revista del Hospital Materno Infantil Ramón Sardá 01/2009;
Source: DOAJ
0 Bookmarks
 · 
95 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Red blood cell alloantibody production was studied in 90 neonates who received a mean of 14.1 transfusions (range 2-35) from an average of 8.9 donors during the first three months after birth. Standard antibody detection procedures were done with the use of a selected red blood cell panel. No unexpected alloantibodies were detected. These findings suggest, at a 99% confidence level, that neonates do not make red blood cell alloantibodies in response to transfusion, indicating that repeated compatibility testing is probably unnecessary. Thus, following initial antibody screening and compatibility tests, further compatibility testing can be eliminated.
    American Journal of Clinical Pathology 03/1987; 87(2):250-1. · 2.88 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Although concern over the risks of red blood cell transfusion has resulted in several practice guidelines for transfusion, lack of data regarding the physiological effects of anemia in humans has caused uncertainty regarding the blood hemoglobin (Hb) concentration requiring treatment. To test the hypothesis that acute isovolemic reduction of blood Hb concentration to 50 g/L in healthy resting humans would produce inadequate cardiovascular compensation and result in tissue hypoxia secondary to inadequate oxygen transport. Before and after interventional study. Academic tertiary care medical center. Conscious healthy patients (n =11) prior to anesthesia and surgery and volunteers not undergoing surgery (n=21). Aliquots of blood (450-900 mL) were removed to reduce blood Hb concentration from 131 (2) g/L to 50 (1) g/L [mean (SE)]. Isovolemia was maintained with 5% human albumin and/or autologous plasma. Cardiovascular parameters, arterial and mixed venous oxygen content, oxyhemoglobin saturation, and arterial blood lactate were measured before and after removal of each aliquot of blood. Electrocardiogram and, in a subset, Holter monitor were monitored continuously. "Critical" oxygen delivery (TO2) as assessed by oxygen consumption (VO2), plasma lactate concentration, and ST changes on electrocardiogram. Acute, isovolemic reduction of Hb concentration decreased systemic vascular resistance and TO2 and increased heart rate, stroke volume, and cardiac index (each P<.001). We did not find evidence of inadequate oxygenation: VO2 increased slightly from a mean (SD) of 3.07 (0.44) mL of oxygen per kilogram per minute (mL O2 x kg(-1) x min[-1]) to 3.42 (0.54) mL O2 x kg(-1) x min(-1) (P<.001) and plasma lactate concentration did not change (0.81 [0.11] mmol/L to 0.62 [0.19] mmol/L; P=.09). Two subjects developed significant ST changes on Holter monitor: one apparently related to body position or activity, the other to an increase in heart rate (at an Hb concentration of 46-53 g/L); both occurred in young women and resolved without sequelae. Acute isovolemic reduction of blood Hb concentration to 50 g/L in conscious healthy resting humans does not produce evidence of inadequate systemic TO2, as assessed by lack of change of VO2 and plasma lactate concentration. Analysis of Holter readings suggests that at this Hb concentration in this resting healthy population, myocardial ischemia would occur infrequently.
    JAMA The Journal of the American Medical Association 01/1998; 279(3):217-21. · 29.98 Impact Factor
  • Source

Full-text

View
0 Downloads
Available from