Article

Depth of electrode insertion and postoperative performance in humans with cochlear implants: a histopathologic study.

Department of Otology and Laryngology, Harvard Medical School, Boston, Mass., USA.
Audiology and Neurotology (Impact Factor: 1.85). 03/2010; 15(5):323-31. DOI: 10.1159/000289571
Source: PubMed

ABSTRACT The depth of electrode insertion of a multichannel cochlear implant has been suggested as a clinical variable that may correlate with word recognition using the implant. The current study evaluates this relationship using the human temporal bone collection at the Massachusetts Eye and Ear Infirmary. Twenty-seven temporal bones of subjects with cochlear implants were studied. Temporal bones were removed at autopsy, fixed and prepared for histological study by standard techniques. Specimens were then serially sectioned, and reconstructed by two-dimensional methods. Three measures of length were made from each subject's reconstruction: (1) depth of insertion (DI) of the cochlear implant electrode array, from the round window to the array's apical tip; (2) inserted length (IL) from the cochleostomy to the apical tip of the array, and (3) cochlear duct length (CDL) from the round window to the helicotrema. The active electrode length (AEL) was defined as the distance between the most apical and most basal electrodes of the array. Stepwise regression was used to identify whether subsets of six metrics associated with insertion depth (DI, DI/AEL, DI/CDL, IL, IL/AEL and IL/CDL), duration of deafness, sound-processing strategy, potential for central impairment and age at implantation accounted for significant across-subject variance in the last recorded NU-6 word score measured during each subject's life. Age at implantation and potential for central impairment account for significant percentages of the across-subject variance in NU-6 word scores for the 27 subjects studied. None of the insertion metrics accounted for significant performance variance, even when the variance associated with the other variables was controlled. These results, together with those of previous studies, are consistent with a relatively weak association between electrode insertion depth and speech reception.

0 Followers
 · 
85 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Patients with single sided deafness have recently begun receiving cochlear implants in their deaf ear. These patients gain a significant benefit from having a cochlear implant. However, despite this benefit, they are considerably slower to develop binaural abilities such as summation compared to bilateral cochlear implant patients. This suggests that these patients have difficulty fusing electric and acoustic signals. Although this may reflect inherent differences between electric and acoustic stimulation, it may also reflect properties of the processor and fitting system, which result in spectral and temporal compression. To examine the possibility that unilateral spectral and temporal compression can adversely affect binaural fusion, this study tested normal hearing listeners’ binaural fusion through the use of vocoded speech with unilateral spectral and temporal compression. The results indicate that unilateral spectral and temporal compression can hinder binaural fusion and thus may adversely affect binaural abilities in patients with single sided deafness who use a cochlear implant in their deaf ear.
    Hearing Research 12/2014; 320. DOI:10.1016/j.heares.2014.12.005 · 2.85 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Beside the cochlear size, the linear insertion depth (LID) influences the insertion depth angle of cochlear implant electrode arrays. For the specific implant CI422 the recommended LID is not fixed but can vary continuously between 20 and 25 mm. In the current study, the influence of cochlea size and LID on the final insertion depth angle was investigated to develop a prediction tool for the insertion depth angle by means of cochlea diameter and LID. Preoperative estimation of insertion depth angles might help surgeons avoid exceeding an intended insertion depth, especially with respect to low-frequency residual hearing preservation. Postoperative, high-resolution 3D-radiographs provided by Flat Panel Computed Volume Tomography (FPCT) were used to investigate the insertion depth angle in 37 CI422 recipients. Furthermore, the FPCT images were used to measure linear insertion depth and diameter of the basal turn of the cochlea. A considerable variation of measured insertion depth angles ranging from 306° to 579° was identified. The measured linear insertion depth ranged from -18.6 to 26.2 mm and correlated positively with the insertion depth angle. The cochlea diameter ranged from 8.11 to 10.42 mm and correlated negatively with the insertion depth angle. The results suggest that preoperatively measured cochlea diameter combined with the option of different array positions by means of LID may act as predictors for the final insertion depth angle.
    Archiv für Klinische und Experimentelle Ohren- Nasen- und Kehlkopfheilkunde 11/2014; DOI:10.1007/s00405-014-3352-4 · 1.61 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The merits of electrode deep insertion and modern coding strategies.•Flexible and free fitting lateral wall electrodes are minimally traumatic.•Hearing preservation results establish the atraumaticity of an electrode.•Faithful sound coding in a CI requires correct tonotopic and temporal coding.•Fine structure coding strategies combine correct tonotopic and temporal coding.
    Hearing Research 10/2014; DOI:10.1016/j.heares.2014.10.006 · 2.85 Impact Factor