Notification of abnormal lab test results in an electronic medical record: do any safety concerns remain?

Hardeep Singh, Eric J Thomas, Dean F Sittig, Lindsey Wilson, Donna Espadas, Myrna M Khan, Laura A Petersen

Michael E. DeBakey Veterans Affairs Medical Center and the Section of Health Services Research, Department of Medicine, Baylor College of Medicine, Houston, TX, USA.

Journal Article: The American journal of medicine (impact factor: 4.47). 03/2010; 123(3):238-44. DOI: 10.1016/j.amjmed.2009.07.027

Abstract

Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions.
We studied 4 alerts: hemoglobin A1c > or =15%, positive hepatitis C antibody, prostate-specific antigen > or =15 ng/mL, and thyroid-stimulating hormone > or =15 mIU/L. An alert tracking system determined whether the alert was acknowledged (ie, provider clicked on and opened the message) within 2 weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (eg, patient contact, treatment). Multivariable logistic regression models analyzed predictors for lack of timely follow-up.
Between May and December 2008, 78,158 tests (hemoglobin A1c, hepatitis C antibody, thyroid-stimulating hormone, and prostate-specific antigen) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%), and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs 10.1%; P =.13). Of 1163 alerts, 202 (17.4%) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (odds ratio 7.35; 95% confidence interval, 4.16-12.97), whereas alerts related to redundant tests were less likely to lack timely follow-up (odds ratio 0.24; 95% confidence interval, 0.07-0.84).
Safety concerns related to timely patient follow-up remain despite automated notification of non-life-threatening abnormal laboratory results in the outpatient setting.

Source: PubMed

Comments on this publication

ResearchGate members can add comments. Sign up now and post your comment!

Similar publications

Science & Research Jobs

Keywords

2 weeks
 
4 alerts
 
95% confidence interval
 
abnormal laboratory results
 
abnormal outpatient laboratory test results
 
Electronic medical records
 
hepatitis C antibody
 
integrated electronic medical record
 
lack timely follow-up
 
major patient safety concern
 
non-life-threatening abnormal laboratory results
 
positive hepatitis C antibody
 
provider clicked
 
record review
 
redundant tests
 
thyroid-stimulating hormone
 
timely follow-up
 
timely follow-up actions
 
timely patient follow-up
 
unacknowledged alerts