Shamsipur, M., et al.: Novel fluorimetric bulk optode membrane based on 5,8-bis((5’-chloro-8’-hydroxy-7’-quinolinyl)methyl)-2,11-dithia-5,8-diaza-2,6-pyridinophane for selective detection of lead(II) ions. Talanta 80, 2023-2033

Department of Chemistry, Razi University, Kermanshah, Iran.
Talanta (Impact Factor: 3.55). 03/2010; 80(5):2023-33. DOI: 10.1016/j.talanta.2009.11.011
Source: PubMed


A novel fluorescence chemical sensor for the highly sensitive and selective determination of Pb(2+) ions in aqueous solutions is described. The preliminary potentiometric and spectrofluorimetric complexation studies in solution revealed that the lipophilic ligand 5,8-bis((5'-chloro-8'-hydroxy-7'-quinolinyl)methyl)-2,11-dithia-5,8-diaza-2,6-pyridinophane (L2) forms a highly stable and selective [PbL2](2+) and [Pb(L2)(2)](2+) complexes which results in a strong fluorescence quenching of the ligand. Thus, a novel fluorescence Pb(2+) sensing system was prepared by incorporating L2 as a neutral lead-selective fluoroionophore in the plasticized PVC membrane containing tetrakis(p-chlorophenyl) borate as a liphophilic anionic additive. The response of the sensor is based on the strong selective fluorescence quenching of L2 by Pb(2+) ions. At pH 5.5, the proposed sensor displays a calibration curve over a wide concentration range of 3.0 x 10(-7) to 2.5x 10(-2)M with a relatively fast response time of less than 5 min. In addition to high stability, reversibility and reproducibility, the sensor shows a unique selectivity towards Pb(2+) ion with respect to common coexisting cations. The proposed fluorescence optode was successfully applied to the determination of lead in plastic toys and tap water samples.

20 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: In this study, a highly sensitive PVC–membrane sensor based on 4-methoxyphenylcyanamide (4-MeOpcyd) as a neutral carrier was prepared and the specific interaction between Gd3+ ions and ionophore at the surface of selective polymeric membrane was calculated using the PM6/SPARKLE semiempirical method. The results of the Mopac2009 calculations show selective complexation of Gd3+ by 4-MeOpcyd ligand that correlate quite well with experimental data. This membrane sensor has a linear response in the range of 1.0×10−6–1.0×10−2 M Gd3+ with detection limit of 6.2×10−7 M. This electrode was applied in potentiometric titration for determination of gadolinium and also for fluoride ions in the mouthwash samples with satisfactory results.
    Electroanalysis 04/2011; 23(4):1029 - 1037. DOI:10.1002/elan.201000624 · 2.14 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A new optical sensor was fabricated for determination of beryllium ions. The optode membrane was prepared by incorporation of 1,8-dihydroxyanthrone and sodium tetraphenylborate (NaTPB) in a plasticized poly (vinyl chloride) membrane containing ortho-nitrophenyl octyl ether (o-NPOE) as a plasticizer. Color of the sensing membrane in contact with Be(2+) ions at pH 10.5, was changed from orange to red. The different variables affecting uptake efficiency were evaluated and optimized. Under the optimum conditions (i.e. 28.0% PVC, 60.0% o-NPOE, 8.0% 1,8-dihydroxyanthrone, 4.0% NaTPB and response time of 6 min), the proposed sensor displayed a linear range of 0.1-5 μg mL(-1) with a detection limit of 0.03 μg mL(-1). Also the precision (RSD%) was better than 2.9% for 7 replicate determinations of 1 μg mL(-1) Be in various membranes. The selectivity of the probe was studied for some cations and anions. Experimental results showed that the sensor was high selective in the presence of ethylenediaminetetraacetic acid (EDTA) as a masking agent and could be used as an effective tool in analyzing the beryllium content of water samples.
    Journal of hazardous materials 06/2011; 190(1-3):962-8. DOI:10.1016/j.jhazmat.2011.04.033 · 4.53 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A coated-wire silver ion-selective electrode (ISE) is constructed using 1,2,4,5-tetrakis(8-hydroxyquinolinoxymethyl)benzene (I) as neutral carrier in a poly(vinyl chloride) matrix plasticized with 2-nitrophenyl octyl ether. The best membrane composition (w/w) for the sensor is PVC 33%, plasticizer 63%, ionophore 4%. The sensor exhibited a linear Nernstian response over the concentration range 1 x 10(-5) M to 1 x 10(-1) M with a slope of 60 +/- 1 mV per decade change and a detection limit of 1 x 10(-6) M. The working pH range is 3.5-7.5. The response time of sensor is 15 s and it can be used for at least 2 months without any significant divergence in potential. The sensor shows good selectivity over a number of alkali, alkaline earth and several transition and heavy metal ions. The electrode is used as an indicator electrode for the determination of Ag(+) in various synthetic samples and also used for the determination of SCN(-), CN(-), S(-2) and l(-) contents present in the sample solution.
    Sensor Letters 08/2011; 9(4):1390-1397. DOI:10.1166/sl.2011.1696 · 1.59 Impact Factor
Show more