Conference Paper

A new measuring fixator design for humeral supracondylar corrective osteotomies in children

Dept. of Orthopedic Surg., Chang Gung Memorial Hosp., Taoyuan, Taiwan
DOI: 10.1109/ICSMC.2003.1244334 Conference: Systems, Man and Cybernetics, 2003. IEEE International Conference on, Volume: 3
Source: IEEE Xplore

ABSTRACT Treatment for bone deformities secondary to malunited fractures usually require corrective osteotomies, and high incidence of surgical failure rates have been reported. Inaccurate corrections and loss of reductions are among the most common causes, and these technical errors ought to be improved. A new measuring fixator for humeral supracondylar corrective osteotomies in children was designed and used in clinical application. Two boys who had sustained cubitus varus following malunited humeral supracondylar fracture were performed using proposed measuring fixator. The results of the clinical trial show that the angle of correction was accurate, and the procedure could be carried out by the surgeon himself without additional help, with an average of 1.3 penetration of the physis per each fixating Kirschner wire (8 times in 6 K-wires). The surgical time was reduced, as well as the radiation exposure.

Download full-text

Full-text

Available from: Ming-Yih Lee, Jul 26, 2015
0 Followers
 · 
197 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Reports of corrective procedures for cubitus varus (gunstock deformity) have emphasized the frequency of loss of position and significant complication. Modifications that have been made to the standard supracondylar osteotomy protocol include correction of the angular deformity only, without correction of rotation; an incomplete wedge osteotomy leaving the medial cortex intact by hinging the osteotomy shut on the intact cortex; and immobilization of the elbow in full extension with the forearm supinated. In a review of 16 patients following this protocol, 11 patients had excellent results, three had good results, and two had unsatisfactory results.
    Journal of Pediatric Orthopaedics 01/1990; 10(2):228-31. DOI:10.1097/01241398-199003000-00019 · 1.43 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Between 1970 and 1992, 23 patients with cubitus varus deformities following elbow fractures underwent 26 corrective lateral-wedge osteotomies at Texas Scottish Rite Hospital. Internal fixation was most commonly provided by either small Steinmann pins, two screws and a figure-of-eight wire, or a small two-hole plate. Sixteen patients had a good result and 10 were judged to have poor results. Two of the 10 patients with poor results had inadequate intraoperative correction. Unstable internal fixation allowed osteotomy fragments to slip into varus in the remaining eight poor results (three with Steinmann pins and five with figure-of-eight wire). Nonrigid internal fixation was obvious even in the patients who received good correction of their cubitus varus. Of the 16 patients with good postoperative results, six demonstrated loss of fixation with extension of the distal fragment. In addition, seven patients with poor results also had slippage of the distal osteotomy fragment into extension. These patients had between 5 and 15 degrees of apparent elbow hyperextension with concomitant loss of elbow fixation. We now recommend a two-hole lateral plate and a percutaneous medial pin to enhance the stability of internal fixation.
    Journal of Pediatric Orthopaedics 07/1994; 14(4):487-91. DOI:10.1097/01241398-199407000-00012 · 1.43 Impact Factor
  • The Journal of Bone and Joint Surgery 02/1972; 54(1):60-6. · 4.31 Impact Factor
Show more