Article

Control de gustos y olores en las aguas de consumo. II. Descripciones y análisis químico

Cerveza y malta, ISSN 0300-4481, Nº. 162, 2004, pag. 39 01/2004;
Source: OAI

ABSTRACT En la primera parte del artículo se introdujeron los conceptos básicos del análisis sensorial del agua, con especial atención a las características del panel de catadores y la dinámica de las sesiones de cata. En esta segunda parte, se centra la atención en el método del FPA (Flavour Profile Analysis) y los descriptores característicos del medio acuático. Se presentan la rueda de descriptores empleada y los perfiles obtenidos aplicando dicho método. Se comenta brevemente el tratamiento de gustos y olores por medio del análisis químico y, por último, se discuten brevemente las aplicaciones fundamentales del análisis organoléptico del agua.

0 Followers
 · 
225 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: A study of organic compounds imparting odor problems in river waters and groundwaters has been conducted. The Tordera aquifer located in Barcelona and Girona (NE Spain) is the water supply reserve for many seasonally crowded villages on the coast. Closed loop stripping analysis (CLSA) and flavor profile analysis (FPA) have been employed as analytical tools to identify the compounds responsible for the odor complaints. The feasibility of purge-and-trap (P&T) has also been evaluated. The 2-alkyl-5,5-dimethyl-1,3-dioxanes and 2-alkyl-4-methyl-1,3-dioxolanes were the most significant compounds identified in river water and groundwater with a threshold odor of 10 ng/L for 2-ethyl-5,5-dimethyl-1,3-dioxane (2EDD), the most malodorous compound. The analyses were carried out by HRGC/MS, and the synthesized 1,3-dioxanes and dioxolanes were characterized by CI-MS and EI-MS/MS techniques. A company, currently manufacturing saturated and unsaturated polyester resins, located in the upper course of the river, produced these compounds as byproducts during the synthesis of resins. The pollution by dioxanes and dioxolanes affected all the aquifer and slowly diminished to the ppt levels when the company was forced to correctly treat their wastewaters. Additional examples of the pres ence of dioxanes and dioxolanes in wastewaters of other resin plants and also tap water of Barcelona are shown.
    Environmental Science and Technology 01/1998; 32(2):206-216. DOI:10.1021/es9704085 · 5.48 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A study of organic pollutants causing odor events in the groundwater from the Lower Llobregat aquifer system has been conducted. This aquifer acts as water reserve of Barcelona (northeast Spain) when the quality of the raw water from the Llobregat River is low. Closed-loop stripping analysis (CLSA), purge-and-trap (P&T), sensory GC, and flavor profile analysis (FPA) have been used as analytical methodologies to identify the compounds responsible for the odor events. Industrial organochlorinated solventsdi- to hexachlorinated saturated and unsaturated hydrocarbons dicyclopentadiene (DCPD) and its derivatives 8-dihydroDCPD, tetrahydroDCPD, and adamantane (the trimer of DCPD) are among the most significant compounds identified in the groundwater. DCPD with a mean concentration of <1 μg/L in almost all analyzed wells is the compound causing the odor incidents, regardless that some organochlorinated solvents such as 1,1,2-trichloroethane, trichloroethylene, and perchloroethylene might be even 2 or 3 orders of magnitude more concentrated than DCPD. The synthesis of dihydroDCPD was performed for confirmatory purposes. Trained and untrained panelists have established the threshold odor for this compound in the range of 10−25 ng/L. Although further research is needed, it is possible that an illegal landfill closed in the 1970s could be the origin of the different pollutants found.
    Environmental Science and Technology 07/1997; 31(8). DOI:10.1021/es960987y · 5.48 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Iodinated trihalomethanes (ITHMs) have been usually considered the disinfection byproducts suspected of causing medicinal odor episodes in treated water around the world. The odor threshold concentration (OTC) of mixed ITHMs (bromochloroiodo-, bromodiiodo-, chlorodiiodo-, dibromoiodo-, and dichloroiodomethane) which were previously synthesized -- because commercial standards are not available-- were determined by using two sensory techniques: flavor profile analysis (FPA), performed by an experienced panel trained in identifying odors and tastes in water; and gas chromatography coupled with olfactometry (GCO). FPA results gave a theoretical OTCs range from 0.1 to 8.9 microg/L and ITHMs were described as sweet, solvent, and medicinal products. The lowest experimental value (OTC(exp)) obtained from the six ITHMs, 0.03 microg/L, corresponded to iodoform.
    Journal of Agricultural and Food Chemistry 05/2001; 49(4):1881-4. DOI:10.1021/jf001252m · 3.11 Impact Factor

Preview

Download
15 Downloads
Available from