Article

Doppler-derived deformation imaging in unsedated healthy adult dogs.

Department of Clinical Sciences, College of Veterinary Medicine, Oregon State University, 272 Magruder Hall, Corvallis, OR, USA.
Journal of veterinary cardiology: the official journal of the European Society of Veterinary Cardiology 10/2009; 11(2):89-102. DOI: 10.1016/j.jvc.2009.06.001
Source: PubMed

ABSTRACT To evaluate feasibility, repeatability and reproducibility (R&R) of Doppler-derived deformation imaging (DI) in healthy adult dogs.
Forty-nine dogs underwent physical examination, ECG, blood pressure measurement and echocardiography. Doppler-derived DI parameters obtained from six selected Regions of Interest (ROI) within the left ventricle (LV) were: strain (S), systolic strain rate (SSR), strain rate E wave (SRE), and strain rate A wave (SRA). The averages of the six ROIs were calculated and labeled avS, avSSR, avSRE, and avSRA. Randomly selected dogs underwent two echocardiographic studies to evaluate intraoperator (n=14) and interoperator (n=17) variability.
DI data were obtained in 87.2% of dogs and 77.2% of ROIs. Compared to controls, avSSR was significantly reduced in Doberman Pinchers (DP) and it was increased in dogs < 30 kg, compared to dogs > 30 kg. The intraoperator Coefficient of Variability (CV) for some ROIs was greater than 15% but for averaged measurements it was < or = 5.0%. Interoperator CV varied widely but were all < 15% for avSSR, avS, and avSRA.
The CV for Doppler-derived DI varied widely. Averaging values from multiple ROIs improved R&R. DI may help elucidate differences in LV mechanics between canine breeds.

0 Followers
 · 
81 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: This paper reports a novel fabrication process of 3 dimensional (3-D) micro structures by double X-ray exposure in standard deep X-ray lithography (DXL). The proposed fabrication process made it possible to realize 3-D microstructures with an inclined and curved sidewall without any apparatuses and difficult process control. In order to demonstrate the feasibility of the double X-ray exposure technique, a micro-needle array fabrication was carried out. The sharp micro-needle array with the top radius of less than 100 nm was easily and successfully fabricated by the double X-ray exposure method.
    Micro Electro Mechanical Systems, 2004. 17th IEEE International Conference on. (MEMS); 02/2004
  • [Show abstract] [Hide abstract]
    ABSTRACT: Compared to conventional polycrystalline silicon (poly-Si), re-crystallized (RC) metal-induced laterally crystallized (MILC) poly-Si possesses improved mechanical and electrical properties. RC-MILC poly-Si piezoresistors exhibit ∼25% increase in gauge factor and ∼50% reduction in noise level compared to conventional poly-Si piezoresistors. RC-MILC poly-Si transistors exhibit performance approaching those built on single-crystal silicon. As a demonstration of the feasibility of using the RC-MILC poly-Si technology to realize non-trivial micro-systems, microphone integrating piezoresistive strain sensors and amplifiers has been designed, fabricated and characterized.
    Micro Electro Mechanical Systems, 2004. 17th IEEE International Conference on. (MEMS); 02/2004
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Loss of temporal synchrony of myocardial contraction has been shown to reduce systolic function and be responsible for disease progression in people. The objective of this study is the assessment of inter- and intra ventricular synchrony in healthy Doberman Pinschers and those with dilated cardiomyopathy (DCM) by use of conventional Doppler and tissue velocity imaging. A total of 60 scans from 35 client-owned Doberman Pinschers presented for cardiac evaluation were analysed. Retrospective analysis of data. Using the European Society of Veterinary Cardiology DCM taskforce scoring system, Doberman Pinschers were classified into 4 groups: Control (Group 1; n=12), depressed systolic function other than DCM (Group 2; n=9), preclinical DCM (Group 3; n=8) and symptomatic DCM (Group 4; n=6). The time intervals between the beginning of the QRS complex and the peak velocity of pulmonic flow (Q-P) and the peak aortic flow (Q-Ao) were used to assess global synchrony between both ventricles. The time intervals between the beginning of the QRS complex and the peak myocardial systolic velocity (Q-peak S) and the onset of myocardial systolic velocity (Q-start S) were measured at the base of the right and left ventricular free wall (RVFW and LVFW) and interventricular septum (IVS), and used to determine segmental longitudinal inter- and intra ventricular synchrony. No significant loss of global or segmental longitudinal inter- or intra ventricular synchrony was identified between the groups. Impairment of longitudinal fibre synchrony does not appear to be significantly associated with clinical status of DCM in Doberman Pinschers, although it was identified in certain individuals.
    Journal of veterinary cardiology: the official journal of the European Society of Veterinary Cardiology 08/2011; 13(3):183-95. DOI:10.1016/j.jvc.2011.05.003