Article

On-Demand DNA Synthesis on Solid Surface by Four Directional Ejectors on a Chip

Univ. of Southern California, Los Angeles
Journal of Microelectromechanical Systems (Impact Factor: 2.13). 11/2007; DOI: 10.1109/JMEMS.2007.901110
Source: IEEE Xplore

ABSTRACT This paper presents a synthesis technique for any random deoxyribonucleic acid (DNA) sequences on different substrates such as glass, plastic or silicon by an array of directional droplet ejectors. Any DNA sequence can be synthesized by ejecting droplets of DNA bases by an ultrasonic transducer having lens with air-reflectors (LWARs) that requires no nozzle. The LWAR is capable of ejecting liquid droplets around 80 mum in diameter, and reduces the amount of reagents needed for the synthesis from most of conventional microarray techniques. One major advantage of the nozzleless ejector is that it can eject droplets in any direction, so that a spot can be inked by four ejectors (carrying four DNA bases) without moving the ejector. The directional ejection of the droplets removes the need for aligning the substrate with the ejector, and minimizes the automation and control circuitry. To demonstrate the DNA synthesis capability of the directional droplet ejectors, four LWAR ejectors were used to synthesize a 15-mer 5'-CGCCAAGCAGTTCGT-3' on a substrate surface. This paper describes the concept and scheme of the on-demand DNA synthesis (with MEMS ejector integrated with microfluidic components) along with experimental results of an actual DNA synthesis by four directional droplet ejectors.

0 Bookmarks
 · 
55 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: This paper describes an on-chip acoustic ejector array consisting of eight directional droplet ejectors that was designed to ink a spot with eight different droplets without having to move the ejectors. Each of the eight directional ejectors consistently ejects uniform droplets in diameter of 51 μm with a directional angle about 17° (with respect to the normal direction of the liquid surface). When a glass substrate was placed 8 mm away from the ejector array chip, all the ejected droplets from the 8 ejectors were placed within 399 x 1080 μm 2 area. If we exclude two ejectors which had bad alignment with the others, all the 6 droplets were placed within 238 x 380 μm 2 area.
    01/2011;
  • [Show abstract] [Hide abstract]
    ABSTRACT: paper describes a novel design of a multi-directional acoustic ejector with capability of electrical control on the droplet ejection angle by changing the operating frequency. The newly developed ejector consistently ejects uniform droplets in diameter of 70 µm, with electrical control of the directional angle from -30° to 35° (with respect to normal direction of liquid surface plane) as the operating frequency is varied from 16.78 MHz to 19.08 MHz. To produce the electrically adjustable oblique ejections of nano-liter droplets, destructive wave interference is intentionally introduced through a phase-varied lens. With the novel lens, the direction of the droplet ejection depends monotonically on the operating frequency of the driving signal. This paper presents the experimental results, as well as the theoretical analysis and simulation verification of the phase-varied lens design that gives the electrical control on the direction of ejected droplets.
    Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS) 01/2011;
  • [Show abstract] [Hide abstract]
    ABSTRACT: A recent acoustic MEMS transducer, a mass sensor based on FBAR (film bulk acoustic resonator), is shown to detect addition of a single DNA base. As the FBAR sensor can detect minute amount of DNA (and/or RNA) markers without the need for optical imaging, it will enable us to develop an “easy to use” and reliable system to detect the presence of pathogen's nucleic acids in non-invasive fluids, such as urine and saliva, when arrayed on a small chip and coupled with a simple sample preparation and an “on-chip” isothermal nucleic acid amplification techniques. Another recent acoustic MEMS, self-focusing acoustic transducers (SFATs) are ideally suited for on-chip DNA and protein synthesis, high frequency ultrasonic imaging, cell lysis or high-intensity ultrasonic treatment with excellent localization on particular cells over a micron-sized area. The focused acoustic beam generated by SFAT is strong and precise enough to eject micron-sized droplets at any desired direction, activate cell-detaching cavitation, and/or lyse cells.
    01/2010;