A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius—A biomechanical study

AO Research Institute, AO Foundation, Clavadelerstrasse 8, 7270 Davos, Switzerland.
Injury (Impact Factor: 2.14). 10/2009; 41(2):204-9. DOI: 10.1016/j.injury.2009.09.025
Source: PubMed


Non-bridging external fixation has recently been introduced as an alternative to volar angular stable plating for the fixation of unstable intra-articular distal radial fractures. The purpose of this study was to biomechanically compare a new non-bridging external fixator construct to volar angular stable plate fixation in a dorsally comminuted intra-articular fracture model of the distal radius.
Five pairs of fresh frozen human cadaveric radii were randomly supplied with either a non-bridging external fixator or a stainless steel volar locking plate. A three-fragmental AO 23-C2.1 fracture was created by removing a 15 degrees dorsal wedge with remaining volar cortical contact and by an intra-articular osteotomy lateral to the lister-tubercle. Physiological load transfer via the wrist was simulated by means of a custom-made seesaw. For biomechanical testing, the bones were loaded in cyclic axial compression. Starting at 100N, the load was monotonically increased at 0.025 degrees N per cycle until failure of the construct. Motion of the lunate and scaphoid fragments with respect to the radial diaphysis was acquired by optical three-dimensional (3D) motion tracking. Plastic wedge deformation was determined after 2000, 4000 and 6000 cycles.
The amplitude of wedge motion at the beginning of the test as a measure for construct stiffness was significantly lower for the fixator group (P=0.003, power=0.99). Plastic wedge deformation after 2000, 4000 and 6000 cycles was found significantly lower for the external fixator (repeated measures analysis of variance (ANOVA), P=0.009, power=0.86). Displacement of the intra-articular gap was found below 0.6mm (mean) for both groups (P>0.05).
The study revealed superior biomechanical properties of the proposed non-bridging external fixation compared to volar locked plating in an unstable intra-articular fracture model with volar cortical support. However, both fixation techniques seem to apply sufficient stabilisation to restore and retain anatomy after fracture of the most distal part of the radius and should be individually chosen according to distinct criteria.

18 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: Distal radius fractures are a common disorder in industrialized nations associated with osteoporosis, with a reported incidence of two fractures per thousand patients per year. We performed a retrospective study comparing two sets of 40 patients, with fracture of the distal radius treated with Penning external fixator, compared to 40 patients treated with fixed-angle volar-locking plate (Plate Depuy ® DVR), with the objective of finding differences between both treatment methods in anatomical values, functional outcomes and complication rates. All fractures were classified according to the AO classification. Postero-anterior and lateral radiographs of the wrist were taken after fracture, after surgery and at 6 months after surgery. We also assessed functional outcome. Minimum follow up was of 10 months. We compared complications between both groups. In the group of patients treated with fixed-angle volar-locked plate, radiological results are found to be closer to the anatomical references. Final outcomes revealed similar functional scores between both groups. The complications rate was statistically higher in the group of patients who underwent external fixation. In the fixed-angle volar-locked plate group, most of complications were related to patient discomfort due to the volar-locking plate.
    12/2012; 4(2). DOI:10.1007/s12593-012-0072-0
  • [Show abstract] [Hide abstract]
    ABSTRACT: All-optical gate switching with a high extinction ratio was characterized. A faster and a slower decay component were observed. The slower one will be suppressed with optimized quantum well structures and properly selected operation wavelengths.
    Lasers and Electro-Optics, 2005. CLEO/Pacific Rim 2005. Pacific Rim Conference on; 09/2005
  • [Show abstract] [Hide abstract]
    ABSTRACT: Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The purpose of the present study was to investigate whether the technique provides stability to match that of conventional (fixed-angle) angle-stable constructs. In seven pairs of human cadaver radii, an Arbeitsgemeinschaft für Osteosynthese (AO) 23 C2.1 intra-articular fracture was created. One radius of each pair received a juxta-articular 2.4-mm locking compression plate (LCP) Volar Distal Radius Plate, whilst the contralateral one received a 2.4-mm Variable Angle Locking Compression Plate (LCP) Two-Column Volar Distal Radius Plate (both plates: Synthes, Oberdorf, Switzerland). Parameters tested were construct stiffness (static axial loading with 150 N), range of motion and secondary loss of reduction (dynamic 150 N axial loading over 5000 cycles). Stiffness and range of motion were measured both pre- and post-cycling. The polyaxial constructs were significantly stiffer, both before and after cyclic testing. However, the two-column plates showed a significant loss of stiffness during cyclic testing. The range of motion was significantly greater, both initially and at the end of cyclic testing, in the fixed-angle constructs. The conventional constructs had significantly greater secondary loss of reduction. The polyaxial two-column plate tested in this study provides a biomechanically sound construct for the management of intra-articular fractures of the distal radius.
    Injury 02/2011; 42(11):1248-52. DOI:10.1016/j.injury.2010.12.005 · 2.14 Impact Factor
Show more