Article

Assessment of Myocardial Blood Flow (MBF) in Humans Using Arterial Spin Labeling (ASL): Feasibility and Noise Analysis

Ming Hsieh Department of Electrical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California 90089-2564, USA.
Magnetic Resonance in Medicine (Impact Factor: 3.4). 10/2009; 62(4):975-83. DOI: 10.1002/mrm.22088
Source: PubMed

ABSTRACT Arterial spin labeling (ASL) is a powerful tool for the quantitative measurement of tissue blood flow, and has been extensively applied to the brain, lungs, and kidneys. ASL has been recently applied to myocardial blood flow (MBF) measurement in small animals; however, its use in humans is limited by inadequate signal-to-noise ratio (SNR) efficiency and timing restrictions related to cardiac motion. We present preliminary results demonstrating MBF measurement in humans, using cardiac-gated flow-sensitive alternating inversion recovery (FAIR) tagging and balanced steady-state free precession (SSFP) imaging at 3T, and present an analysis of thermal and physiological noise and their impact on MBF measurement error. Measured MBF values in healthy volunteers were 1.36 +/- 0.40 ml/ml/min at rest, matching the published literature based on quantitative (13)N-ammonia positron emission tomography (PET), and increased by 30% and 29% with passive leg elevation and isometric handgrip stress, respectively. With thermal noise alone, MBF can be quantified to within +/- 0.1 ml/ml/min with 85.5% confidence, for 3.09 cm(3) regions averaged over 6 breath-holds. This study demonstrates the feasibility of quantitative assessment of myocardial blood flow in humans using ASL, and identifies SNR improvement and the reduction of physiological noise as key areas for future development.

Download full-text

Full-text

Available from: Krishna S Nayak, Jul 05, 2015
0 Followers
 · 
215 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: The paper analyzes the importance of adaptive user detection ordering in an adaptive successive multiuser decision feedback detection scheme with imperfect feedback. The analysis shows that a better performance in terms of bit error rate (BER) is obtained if the less erroneous users are detected first. We propose a new user detection ordering method based on mean squared error (MSE) measurements in the training period. A significant BER gain is obtained with respect to the case when the users are detected based on the decrease of the received powers or in an arbitrary order. An adaptive least mean square (LMS) algorithm is used to determine the users detection order as well as to estimate adaptive filter coefficients.
    Vehicular Technology Conference, 2004. VTC2004-Fall. 2004 IEEE 60th; 10/2004
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The past year has witnessed ongoing progress in the field of molecular MRI of the myocardium. In addition, several novel fluorescent agents have been introduced and used to image remodeling in the injured myocardium. New techniques to image myocardial microstructure, such as diffusion spectrum MRI, have also been introduced and have tremendous potential for integration and synergy with molecular MRI. In the current review we focus on these and other advances in the field that have occurred over the past year.
    Current Cardiovascular Imaging Reports 02/2010; 3(1):26-33. DOI:10.1007/s12410-010-9007-y
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: In subtractive imaging modalities, the differential longitudinal magnetization decays with time, necessitating signal-efficient scanning methods. Balanced steady-state free precession pulse sequences offer greater signal strength than conventional spoiled gradient echo sequences, even during the transient approach to steady state. Although traditional balanced steady-state free precession requires that each excitation pulse use the same flip angle, operating in the transient regimen permits the application of variable flip angle schedules that can be tailored to optimize certain signal characteristics. A computationally efficient technique is presented to generate variable flip angle schedules efficiently for any optimization metric. The validity of the technique is shown using two phantoms, and its potential is demonstrated in vivo with a variable angle schedule to increase the signal-to-noise ratio (SNR) in myocardial tissue. Using variable flip angles, the mean SNR improvement in subtractive imaging of myocardial tissue was 18.2% compared to conventional, constant flip angle, balanced steady-state free precession (P = 0.0078).
    Magnetic Resonance in Medicine 02/2010; 63(2):537-42. DOI:10.1002/mrm.22255 · 3.40 Impact Factor