Variation in detection of adenomas and polyps by colonoscopy and change over time with a performance improvement program.

Department of Medicine, Minneapolis Veterans Affairs Medical Center, Minneapolis, Minnesota, USA.
Clinical gastroenterology and hepatology: the official clinical practice journal of the American Gastroenterological Association (Impact Factor: 6.53). 09/2009; 7(12):1335-40. DOI: 10.1016/j.cgh.2009.07.027
Source: PubMed

ABSTRACT There has been no prospective, community-based study to track changes in adenoma detection by individual physicians over time and to determine the effectiveness of targeted educational interventions.
We prospectively collected information on 47,253 screening colonoscopies in average-risk individuals 50 years and older performed by a community-based practice in the Twin Cities of Minnesota. During a period of 3 years, 5 specific interventions were implemented; each was designed to improve adenoma detection rates. Controlling for patient-related and procedure-related factors, rates of adenoma detection and 3-year trends for individual physicians were plotted, and intraclass correlation coefficients were calculated. Generalized estimating equations were used to identify factors associated with detection of adenomas and polyps.
At least 1 polyp and 1 adenoma were found in 36% and 22% of examinations, respectively. Adenoma detection rates by endoscopists ranged from 10%-39%. There was no significant improvement during the study period despite planned, systematic interventions. Factors associated with adenoma detection included age of the patient (odds ratio [OR], 1.02; 95% confidence interval [CI], 1.02-1.02), male sex (OR, 1.53; 95% CI, 1.34-1.74), and adequate preparation quality (OR, 2.26; 95% CI, 1.64-3.12).
The detection of adenomas by individual physicians during a 3-year period varied and did not appear to change between individual endoscopists, despite planned, systematic interventions. This indicates that other targeted interventions might be required to improve adenoma detection rates among experienced, community gastroenterologists.

0 Followers
 · 
99 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Standards for the detection of adenomas during screening colonoscopy are widely used to measure examination quality. No such standards exist for sessile serrated adenomas (SSAs). To measure both the adenoma detection rate (ADR) and SSA detection rate (SSADR) during screening colonoscopy before and after quality improvement/financial incentive measures. Retrospective determination of baseline ADR/SSADR by the endoscopist, followed by prospective collection of data after informing physicians of baseline detection rates. Tertiary cancer center with a large cancer screening program. A total of 2833 average-risk colorectal cancer screening patients 50 to 75 years of age undergoing initial colonoscopy. Electronic medical records for indication and demographics, endoscopy report, and pathology report. Detection rates of adenomas and SSAs by sex. The overall ADR in male and female patients was 50.6% and 36.6%, respectively. The overall detection rate of advanced adenomas in male and female patients was 12.4% and 6.5%, respectively. The overall SSADR in male and female patients was 10.1% and 7.1%, respectively. In 108 patients (3.8% of entire group), SSAs were the only premalignant lesions found. Detection rates of both types of premalignant polyps improved over time but did not reach statistical significance. Single-center experience with limited sample size and small group of endoscopists. ADRs far in excess of current standards are achievable. Cecal withdrawal time is associated with the ADR. Prevalence of SSA rivals that of advanced adenomas and is greater than current medical literature suggests. The combination of monitoring and financial incentives did not result in statistically significant improvement in ADRs. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
    Gastrointestinal Endoscopy 01/2015; 81(3). DOI:10.1016/j.gie.2014.07.030 · 4.90 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Adenoma detection rate (ADR) has emerged as a key quality metric for colonoscopy. Despite limitations, its major strength is based on its proven correlation with interval colorectal cancer. This has prompted extensive efforts to identify factors and interventions that improve ADR. Potentially modifiable factors that may influence ADR can be patient related (eg, bowel preparation), endoscopist related (eg, withdrawal time, quality of mucosal inspection, additional observers), or procedure related (eg, water infusion, additional examination of right colon, change in position, antispasmodics, colonoscopic equipment, and accessories). Providing endoscopists with educational material and/or feedback also seems to improve ADR.
    Journal of Clinical Gastroenterology 02/2015; DOI:10.1097/MCG.0000000000000293 · 3.19 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Background. Quality monitoring and improvement is prerequisite for efficient colonoscopy. Aim. To assess the effects of increased sedation administration on colonoscopy performance. Materials and Methods. During Era 1 we prospectively measured four colonoscopy quality indicators: sedation administration, colonoscopy completion rate, adenoma detection rate, and early complications rate in three cohorts: cohort A: intention for total colonoscopy cases; cohort B: cohort A excluding bowel obstruction cases; cohort C: CRC screening-surveillance cases within cohort B. We identified deficiencies and implemented our plan to optimize sedation. We prospectively evaluated its effects in both short- (Era 2) and long-term period (Era 3). Results. We identified that sedation administration and colonoscopy completion rates were below recommended standards. After sedation optimization its use rate increased significantly (38.1% to 55.8% to 69.5%) and colonoscopy completion rate increased from 88.3% to 90.6% to 96.4% in cohort B and from 93.2% to 95.3% to 98.3% in cohort C, in Eras 1, 2, and 3, respectively. Adenoma detection rate increased in cohort C (25.9% to 30.6% to 35%) and early complications rate decreased from 3.4% to 1.9% to 0.3%. Most endoscopists increased significantly their completion rate and this was preserved long-term. Conclusion. Increased sedation administration results in long-lasting improvement of colonoscopy quality indicators.
    Gastroenterology Research and Practice 01/2015; 2015:195093. DOI:10.1155/2015/195093 · 1.50 Impact Factor