Article

External-to-internal iliac stent-graft: medium-term patency following exclusion of a retrogradely perfused common iliac aneurysm.

Department of Radiology, York Hospitals NHS Foundation Trust, Wigginton Road, York YO31 8HE, UK.
CardioVascular and Interventional Radiology (impact factor: 2.09). 09/2009; 33(4):849-52. DOI:10.1007/s00270-009-9669-5
Source: PubMed

ABSTRACT Following complicated aortic aneurysm surgery a complete left iliac occlusion resulted in buttock claudication. A retrogradely perfused right common iliac aneurysm expanded. Exclusion was by external-to-internal iliac stent-graft. No deterioration in claudication occurred with medium-term stent-graft patency.