Comparative Study of the Total Acidity Determination in Wine by Potentiometric and Volumetric Titration

Agriculturae Conspectus Scientificus (ACS) 01/2009;
Source: DOAJ

ABSTRACT Total acidity was determined in thirty-seven samples of Croatian red, white and rosé wines by potentiometric titration. In order to find the effect of the corresponding rate of the automatic titrant added, several procedures were employed. For different rates of titration, the aberrances were found from 0.1 to 0.4 g L–1 for some wines. The value of the total acid content in wine determined by the automatic potentiometric titration method was compared to that obtained by the conventional volumetric titration method. The ANOVA and cluster analysis (CA) were applied to detect possible resemblance. The results of total acidity depended on the methods used. However, a good correlation between the results by these methods was found.

2 Followers
 · 
425 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: During the maturation process acids represent an essential factor in wine quality. The amounts of total acids, in 38 different wines, were determined by titrimetric as well as potentiometric methods.Potentiometric titration method gives higher values for total acids content (4.99–10.79 g/l) compared to titrimetric method (3.85–8.68 g/l) as it includes all multi basic acids determination which gives more realistic information about wine acidity.Bestimmung der Gesamtsäuren in Wein mit verschiedenen MethodenDie Säuren stellen während der Prüfung einen wesentlichen Faktor der Qualität von Weinen dar. Von 38 verschiedenen Weinen werden die Gesamtsäuren durch titrimetrische und potentiometrische Methoden bestimmt. Die potentiometrische (4,99–10,79 g/l) ergibt im Vergleich zur titrimetrischen Methode (3,85–8,68 g/l) höhere Werte, da sie die Bestimmung aller multibasischen Säuren einbezieht, die eine realistischere Information über den Weinsäuregrad geben.
    Food / Nahrung 01/1994; 38(4):427-433. DOI:10.1002/food.19940380413
  • [Show abstract] [Hide abstract]
    ABSTRACT: In several samples of Slovenian white wine the concentration of ethanol in extract, pH values, and total acidity were determined, as well as the densities and refractive indices. Total acidity was determined by a classical procedure which is the accepted method of the American Society of Enologists and the AOAC, i.e. the titration of wine with a strong base up to the titration “end point" at pH 8.2. In order to find the true end point, Gran's graphical procedure was employed and some examples of its practical application are illustrated. A Gran's plot converts a logarithmic response to a linear plot and it is shown that in spite of the complex wine matrix, this analytical procedure enables a precise, reproducible and accurate determination of the total acidity of wine.
    Analusis 01/1998; DOI:10.1051/analusis:1998105
  • [Show abstract] [Hide abstract]
    ABSTRACT: An automatic monosegmented flow system (MSFA) based on the binary search concept to perform potentiometric titration is proposed. A tubular hydrogen ion-selective electrode without inner reference solution, consisting of a conducting epoxy cylinder machined with an axial hole coated with tridodecylamine (TDDA) was employed as a sensor. The titration procedure was implemented by exploiting the binary search approach, after each analytical cycle data were evaluated to decide the variation of the titrant volumetric fraction to be inserted for the next cycle. The flow network comprised three-way solenoid valves controlled by a microcomputer running software in QUICKBASIC 4.5. Combination of binary search and MSFA resulted in an automatic system providing possibilities to perform flow titrations without any operator assistance. The main features of the proposed system were verified by titrating hydrochloric and acetic acid solutions and the feasibility of the approach was ascertained by analyzing vinegar, coke, lemon soda, isotonic, industrial and natural orange juice samples. Results were in agreement with those obtained with a conventional potentiometric titration, and no significant difference at 95% confidence level was observed. A 1% standard deviation (n=9) in results was also observed.
    Analytica Chimica Acta 04/1999; 387(2-387):165-173. DOI:10.1016/S0003-2670(99)00092-6 · 4.52 Impact Factor