Electrochemical determination of arsenite in neutral media on reusable gold nanostructured films

Key Laboratory of Analytical Chemistry for Life Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China.
Talanta (Impact Factor: 3.51). 08/2009; 79(2):243-8. DOI: 10.1016/j.talanta.2009.03.037
Source: PubMed

ABSTRACT We report a simple and novel method of stirring-only-driven accumulation and electrochemical determination of arsenite (As(III)) with both of the oxidation and reduction peaks associated with As(0)/As(III) using a gold nanofilm electrode in neutral solution. Under stirring, a large amount of As(III) was deposited on the modified electrode and the electrochemical response was greatly amplified. The accumulated As(III) on the electrode showed well-defined redox couple in 0.1M blank phosphate buffer solution (pH 7.0), which could be used for the measurement of As(III). Under optimal conditions, As(III) could be detected in the range from 0.20 to 375 ppb with a detection limit of 0.04 ppb. In particular, with the use of the reduction peak of As(III) the modified electrode exhibits excellent performance for As(III) determination even in the presence of abundant Cu(II). The regeneration of the electrodes is facile with good reproducibility. The electrochemical system was applied to analyze As(III) in lake water, As(III) spiked tap water and drinking water.

1 Follower
 · 
94 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Contamination of groundwater with arsenic (As) is a major health risk through contamination of drinking and irrigation water supplies. In geochemically reducing conditions As is mostly present as As(III), its most toxic species. Various methods exist to determine As in water but these are not suitable for monitoring arsenic speciation at its original pH and without preparation. We present a method that uses cathodic stripping voltammetry (CSV) to determine reactive As(III) at a vibrating, gold, microwire electrode. The As(III) is detected after adsorptive deposition of As(OH)(3)(0), followed by a potential scan to measure the reduction current from As(III) to As(0). The method is suitable for waters of pH 7-12, has an analytical range of 1 nM to 100 microM As (0.07-7500 ppb) and a limit of detection of 0.5 nM with a 60 s deposition time. The As speciation protocol involves measuring reactive As(III) by CSV at the original pH and acidification to pH 1 to determine inorganic As(III)+As(V) by anodic stripping voltammetry (ASV) using the same electrode. Total dissolved As is determined by ASV after UV-digestion at pH 1. The method was successfully tested on various raw groundwater samples from boreholes in the UK and West Bengal.
    Analytica chimica acta 03/2010; 662(1):1-8. DOI:10.1016/j.aca.2009.12.038 · 4.52 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Determination of the speciation of arsenic in groundwaters, using cathodic stripping voltammetry (CSV), is severely hampered by high levels of iron and manganese. Experiments showed that the interference is eliminated by addition of EDTA, making it possible to determine the arsenic speciation on-site by CSV. This work presents the CSV method to determine As(III) in high-iron or -manganese groundwaters in the field with only minor sample treatment. The method was field-tested in West-Bengal (India) on a series of groundwater samples. Total arsenic was subsequently determined after acidification to pH 1 by anodic stripping voltammetry (ASV). Comparative measurements by ICP-MS as reference method for total As, and by HPLC for its speciation, were used to corroborate the field data in stored samples. Most of the arsenic (78 ± 0.02%) was found to occur as inorganic As(III) in the freshly collected waters, in accordance with previous studies. The data shows that the modified on-site CSV method for As(III) is a good measure of water contamination with As. The EDTA was also found to be effective in stabilising the arsenic speciation for longterm sample storage at room temperature. Without sample preservation, in water exposed to air and sunlight, the As(III) was found to become oxidised to As(V), and Fe(II) oxidised to Fe(III), removing the As(V) by adsorption on precipitating Fe(III)-hydroxides within a few hours.
    Talanta 09/2011; 85(3):1404-1411. DOI:10.1016/j.talanta.2011.06.038 · 3.51 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The electrochemical detection of As(III) was investigated on the novel citrate stabilized gold nanoparticles modified glassy carbon electrode (AuNPs/GCE) in 1 M HCl by square wave anodic stripping voltammetry. AuNPs/GCE was prepared by simply casting citrate stabilized gold nanoparticles onto the well polished glassy carbon electrode. Gold modification was evaluated by cyclic voltammetry, while transmission electron microscopy and UV-vis Spectroscopy revealed the size and distribution of gold nanoparticles. Anodic stripping voltammetry was performed with the modified electrode in As(III) solution. Electrochemical experiments proved that AuNPS/GCE exhibited good performance for As(III) analysis, the linear range were obtained between 0.05 and 1 ppb for trace level of As(III) as well as 1 to 15 ppb, with a limit of detection of 0.025 ppb. In terms of reproducibility, the precision of the above mentioned method in %RSD was calculated at 7.78% (n = 10), and the repeatability of the proposed method was calculated to be 1.59%. The application of the method to analyze As(III) in tap water was investigated.
    Analytical Letters 07/2012; 45. DOI:10.1080/00032719.2012.673108 · 0.98 Impact Factor