Multiple path length dual polarization interferometry

School of Physics and Astronomy, The University of Manchester, Manchester, UK.
Optics Express (Impact Factor: 3.49). 07/2009; 17(13):10959-69. DOI: 10.1364/OE.17.010959
Source: PubMed


An optical sensor for quantitative analysis of ultrathin films and adsorbed layers is described. Quantification of both layer thickness and refractive index (density) can be made for in situ and ex-situ coated films. With the use of two polarizations, in situ measurements are made via one path length in a young's interferometer arrangement while ex-situ measurements use multiple path lengths. The multiple path length young's interferometer arrangement is embodied in a solid state waveguide configuration called the multiple path length dual polarization interferometer (MPL-DPI). The technique is demonstrated with ultrathin layers of poly(methylmethacrylate) and human serum albumin.

Full-text preview

Available from:
  • Source
    • "The multiple path length dual polarization interferometer (MPL-DPI) is a modification of the DPI technology, with the same underlying principles, but with a new waveguide design which allows films coated outside of the instrument to be quantified. The experimental procedure and the method to calculate the refractive index and thickness of ex situ coated films using MPL-DPI was carried out according to a published protocol [28]. The instrument was set to operate at 20 • C. Details of the instrumentations can be found in our previous work [22] "
    [Show abstract] [Hide abstract]
    ABSTRACT: Among the range of materials used in bioengineering, parylene-C has been used in combination with silicon oxide and in presence of the serum proteins, in cell patterning. However, the structural properties of adsorbed serum proteins on these substrates still remain elusive. In this study, we use an optical biosensing technique to decipher the properties of fibronectin (Fn) and serum albumin adsorbed on parylene-C and silicon oxide substrates. Our results show the formation of layers with distinct structural and adhesive properties. Thin, dense layers are formed on parylene-C, whereas thicker, more diffuse layers are formed on silicon oxide. These results suggest that Fn acquires a compact structure on parylene-C and a more extended structure on silicon oxide. Nonetheless, parylene-C and silicon oxide substrates coated with Fn host cell populations that exhibit focal adhesion complexes and good cell attachment. Albumin adopts a deformed structure on parylene-C and a globular structure on silicon oxide, and does not support significant cell attachment on either surface. Interestingly, the co-incubation of Fn and albumin at the ratio found in serum, results in the preferential adsorption of albumin on parylene-C and Fn on silicon oxide. This finding is supported by the exclusive formation of focal adhesion complexes in differentiated mouse embryonic stem cells (CGR8), cultured on Fn/albumin coated silicon oxide, but not on parylene-C. The detailed information provided in this study on the distinct properties of layers of serum proteins on substrates such as parylene-C and silicon oxide is highly significant in developing methods for cell patterning.
    Colloids and surfaces B: Biointerfaces 12/2014; 126. DOI:10.1016/j.colsurfb.2014.12.020 · 4.15 Impact Factor
  • Source
    • "This can hinder calibration results if a chip requires ex situ modification throughout an experiment. A solution to this issue, however, was recently proposed by modifying the channel so that multiple pathlengths are measured [87]. With this adjustment, the number of 2π cycles of the phase shift can be determined if the chip is removed from the instrument, thereby allowing ex situ modification of the chip without the loss of any information. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Biosensors have been used extensively in the scientific community for several purposes, most notably to determine association and dissociation kinetics, protein-ligand, protein-protein, or nucleic acid hybridization interactions. A number of different types of biosensors are available in the field, each with real or perceived benefits over the others. This review discusses the basic theory and operational arrangements of four commercially available types of optical biosensors: surface plasmon resonance, resonant mirror, resonance waveguide grating, and dual polarization interferometry. The different applications these techniques offer are discussed from experiments and results reported in recently published literature. Additionally, recent advancements or modifications to the current techniques are also discussed.
    Sensors 11/2010; 10(11):9630-46. DOI:10.3390/s101109630 · 2.25 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: A novel prism-chamber assembly was prepared for application in optical waveguide based chemical and biological sensors, making the sensor easily and reproducibly operate. By using the prism-chamber assembly, the performance of a composite waveguide based integrated Young interferometer sensor was investigated. The temporal interference pattern detected with a single-slit photodetector heavily relies on the slit width, and regular high-contrast patterns can be obtained under the condition that the slit width is smaller than the spatial periodicity of the sensor. Increasing the temperature of water in the chamber leads to a quasi-linear variation in the phase difference with Deltaphi/DeltaT approximately -9.1 degrees/degrees C. Significant dependence of the sensor's sensitivity on the polarization state of the guided mode was also observed. The sensor is stable and reliable, capable of real-time detection of very slow bioreactions at the interface.
    Optics Express 03/2010; 18(7):7421-6. DOI:10.1364/OE.18.007421 · 3.49 Impact Factor
Show more