Article

Arthroscopic-guided ulnar distraction for the correction of elbow incongruency in four dogs.

Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL, 32610, USA.
Journal of Small Animal Practice (Impact Factor: 0.91). 08/2013; DOI: 10.1111/jsap.12126
Source: PubMed

ABSTRACT Four skeletally immature, small breed dogs (five elbows) with elbow incongruency were evaluated for forelimb lameness. Findings on clinical examination included pain, effusion and decreased range of motion of the affected elbow. Radiography, computed tomography and arthroscopy demonstrated elbow incongruency in all dogs. Fragmented medial coronoid process was diagnosed arthroscopically in three dogs (four elbows). Arthroscopic subtotal coronoidectomy was performed in all cases of fragmented medial coronoid process. Incongruency was corrected with acute ulnar lengthening under arthroscopic visualisation. The ulna was stabilised with a plate following correction. In two elbows an ostectomy of the anconeal process was performed to prevent impingement against the olecranon fossa. All dogs demonstrated improvement in lameness scores and client-scored visual analogue scale scores. Postoperative computed tomography showed significant improvement in elbow incongruency in all dogs. Arthroscopic-guided ulnar lengthening may be considered as a valid treatment in severe cases of elbow incongruency.

0 Followers
 · 
86 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Objective: To assess the effect of arthroscope insertion, using a carbon-fibre rod model, on humero-radial, humero-ulnar and radio-ulnar congruity, as assessed by computed tomography (CT). Methods: Cadaveric Greyhound elbow joints were assessed at a flexion angle of 135 ± 5° using CT. For condition 1, a 36 mm fulcrum induced cubital valgus, as used to aid arthroscope insertion. For conditions 2 and 3, a single 1.8 or 2.5 mm diameter rod was inserted under arthroscopic guidance to simulate arthroscope position for assessment of the medial coronoid process. Repeat CT scans were obtained for all conditions and parasagittal sections were reconstructed to evaluate medial, axial and lateral positions within the elbow. Humero-radial, humero-ulnar, and radio-ulnar congruity measurements were obtained. Differences between groups were assessed using repeated measures analysis of variance. Results: Mean (±SD) change in radio-ulnar step between conditions 1 and 3 was 0.6 ± 0.3 mm (axial), 0.8 ± 0.6 mm (medial), and 0.5 ± 0.1 mm (lateral). Insertion of rods induced a significant decrease in radio-ulnar step in all planes. Significant differences were also identified between groups for humero-radial, humero-ulnar, and radio-ulnar congruity. Clinical significance: Insertion of carbon-fibre rods as a model for elbow arthroscope insertion induces elbow incongruity. Changes in radio-ulnar congruity are small but the effect of arthroscope diameter should be considered when assessing elbow congruity.
    Veterinary and Comparative Orthopaedics and Traumatology 12/2014; 28(1). DOI:10.3415/VCOT-14-02-0017 · 1.03 Impact Factor

Preview

Download
3 Downloads