Intraoperative use of cone-beam computed tomography in a cadaveric ossified cochlea model

Departments of Otolaryngology-Head and Neck Surgery and Surgical Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario, Canada.
Otolaryngology Head and Neck Surgery (Impact Factor: 2.02). 06/2009; 140(5):697-702. DOI: 10.1016/j.otohns.2008.12.046
Source: PubMed


To describe a cadaveric temporal bone model of labyrinthitis ossificans and investigate the utility of intraoperative cone-beam computed tomography (CBCT) in the facilitating cochlear implantation.
Cadaveric temporal bone study.
Five cadaveric heads had cement introduced into the 10 cochleas. CBCT and a conventional CT scan were compared to assess the extent of cochlear obliteration. The cement was drilled-out (under CBCT guidance, if required) and cochlear implant electrode arrays (from 3 different manufacturers) inserted.
CBCT images demonstrated temporal bone anatomy and the extent of cochlear obliteration as clearly as conventional CT in all cases. Intraoperative CBCT guided drilling and facilitated electrode placement in two of five heads (3 of 10 ears). Streak-artifact from the electrodes of two devices partially obscured image clarity.
The obliterated cochlear model reproduced a disease-ossified cochlear both radiographically and surgically. CBCT is useful for intraoperative imaging to facilitate electrode array placement in the obliterated or congenitally abnormal cochlea.

Download full-text


Available from: Gil N Bachar,
25 Reads
  • Source
    • "noise ratio. Even so, the image enables acceptable study of the osseous labyrinthine structures [15] [16]. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Cone-beam imaging is an X-ray based volume acquisition method providing 3D images of the head. The reconstructed volume is "isotropic"; spatial resolution varies according to material, equaling or exceeding that of CT but with a much lower radiation intensity. The drawbacks comprise a reduced signal-to-noise ratio and poor density resolution precluding soft-tissue exploration, notably of tumoral processes. This technique is very effective for the study of inflammatory and infectious processes of the head. In dental exploration, its intrinsic qualities enable screening for sinusitis of dental origin with a precision unobtainable on CT. Cone-beam imaging will, in the near future, become the reference examination in sinus assessment. Finally, this technique, at least using the most powerful apparatuses, seems very promising in ear pathology exploration. First applications in chronic otitis, dysplasia, deformity and trauma have been encouraging. Its low sensitivity to metallic artifacts makes it the technique of choice in the follow-up of cochlear implants.
    European Annals of Otorhinolaryngology, Head and Neck Diseases 03/2011; 128(2):65-78. DOI:10.1016/j.anorl.2010.10.008 · 0.82 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Without considering spatial, stochastic, and temporal features inherent in natural neural systems, the computational power of conventional artificial neural networks (ANNs) is limited. In the present paper, we look at the stochastic complexity and construct a stochastic ANN by modeling stochastic fluctuations in the environmental stimuli such that all stimuli are prone to be corrupted by noise or even outliers and to break networks down; therefore, a positive-breakdown network is required. We investigate the stochasticity in the domain of function approximation (estimation) in the framework of radial basis function networks (RBFNs) and propose a robust RBFN, β-RBFN, by applying the breakdown point approach in robust regression. Experimental results demonstrate the advantages of the proposed networks in robustness and simplicity over the plain RBFNs
    Neural Networks, 1996., IEEE International Conference on; 07/1996
  • [Show abstract] [Hide abstract]
    ABSTRACT: Summary form only given. The polarization tomography features of optically anisotropic architectonic nets of different morphological structure biotissues (BT) have been investigated. The phase tomography (PT) features of skin derma, muscular and bone BT have been experimentally investigated. The interrelation between the PT structure and BT physiological state has been determined. The early diagnostics criteria of the degenerative-dystrophic appearance and pathological changes of the structure of BT optically anisotropic architectonics have been determined: (i) Optical anisotropy of physiologically normal myometry is not practically apparent- the PTs represent a quasi-homogeneous field with several fluctuations Δn(X,Y) ≈ 10<sup>-5</sup>. This points to a rather amorphous optical structure of BT, i.e., to "lack of development" of myometry collagen net. (ii) The phase component topology of the diffusely changed myometry architectonics is formed by the areas with inhomogeneous distribution of birefringence Δn(X,Y), the values of which vary from 1.2 × 10<sup>-4</sup> to 1.1 × 10<sup>-3</sup> respectively. (iii) The tumor-forming processes are accompanied by the formation of "anisotropy zones", within which the birefringence value of architectonics increases by two orders and reaches the level of 2.5 × 10<sup>-3</sup>.
    Laser and Fiber-Optical Networks Modeling, 2004. Proceedings of LFNM 2004. 6th International Conference on; 10/2004
Show more