False positives in functional near-infrared topography

Department of Medical Physics and Bioengineering, Malet Place Engineering Building, University College London, Gower Street, London WC1E 6BT, UK.
Advances in Experimental Medicine and Biology (Impact Factor: 1.96). 02/2009; 645:307-14. DOI: 10.1007/978-0-387-85998-9_46
Source: PubMed


Functional cranial near-infrared spectroscopy (NIRS) has been widely used to investigate the haemodynamic changes which occur in response to functional activation. The technique exploits the different absorption spectra of oxy- and deoxy-haemoglobin ([HbO2] [HHb]) in the near-infrared region to measure the changes in oxygenation and haemodynamics in the cortical tissue. The aim of this study was to use an optical topography system to produce topographic maps of the haemodynamic response of both frontal cortex (FC) and motor cortex (MC) during anagram solving while simultaneously monitoring the systemic physiology (mean blood pressure, heart rate, scalp flux). A total of 22 young healthy adults were studied. The activation paradigm comprised of 4-, 6- and 8- letter anagrams. 12 channels of the optical topography system were positioned over the FC and 12 channels over the MC. During the task 12 subjects demonstrated a significant change in at least one systemic variable (p < or = 0.05). Statistical analysis of task-related changes in [HbO2] and [HHb], based on a Student's t-test was insufficient to distinguish between cortical haemodynamic activation and systemic interference. This lead to false positive haemodynamic maps of activation. It is therefore necessary to use statistical testing that incorporates the systemic changes that occur during brain activation.

Download full-text


Available from: Caroline B Reid, Oct 04, 2015
27 Reads
  • Source
    • "Confounding effects on the observed signal were then estimated and removed during model inversion. Note that additional measurements of systemic confounds e.g., changes in blood pressure (Minati et al., 2011; Tachtsidis et al., 2009; Takahashi et al., 2011) and arterial partial pressure of CO 2 (Scholkmann et al., 2013) can also be used in the proposed method, which may enhance the efficiency of effective connectivity estimates. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Functional near-infrared spectroscopy (fNIRS) is an emerging technique for measuring changes in cerebral hemoglobin concentration via optical absorption changes. Although there is great interest in using fNIRS to study brain connectivity, current methods are unable to infer the directionality of neuronal connections. In this paper, we apply Dynamic Causal Modelling (DCM) to fNIRS data. Specifically, we present a generative model of how observed fNIRS data are caused by interactions among hidden neuronal states. Inversion of this generative model, using an established Bayesian framework (variational Laplace), then enables inference about changes in directed connectivity at the neuronal level. Using experimental data acquired during motor imagery and motor execution tasks, we show that directed (i.e., effective) connectivity from supplementary motor area to primary motor cortex is negatively modulated by motor imagery, and this suppressive influence causes reduced activity in primary motor cortex during motor imagery. These results are consistent with findings of previous functional magnetic resonance imaging (fMRI) studies, suggesting that the proposed method enables one to infer directed interactions in the brain mediated by neuronal dynamics from measurements of optical density changes. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
    NeuroImage 02/2015; 8. DOI:10.1016/j.neuroimage.2015.02.035 · 6.36 Impact Factor
  • Source
    • "Studies have shown transient changes in blood pressure (e.g. [8] [9] [10]) and partial pressure of CO 2 (measured as end-tidal CO 2 ) (e.g. [11] [12] [13]) cause local changes in brain hemodynamics and oxygenation which interfere with the measurement of the local neuro-vascular coupling. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Simultaneous measurement of cortical and peripheral affective processing is relevant in many neuroscientific research fields. The aim was to investigate the influence of different affective task components on the coherence between cortical hemodynamic signals and peripheral autonomic skin potential signals. Seventeen healthy subjects performed four tasks, i.e. a finger-tapping task, a hyperventilation task, a working memory task and a risk-taking task. Cortical hemodynamic responses were measured using functional near-infrared spectroscopy (fNIRS). Peripheral skin conductance responses (SCRs) were assessed using electrodermal activity (EDA). Coherence between the fNIRS and the EDA time series was calculated using the S transform coherence (STC), a method that tests the temporal dynamics between two time series for consistent phase relationships and thus for a functional relationship. The following characteristics of fNIRS-EDA coherence were observed: (1) Simple motor performance was not a contributor to enhanced coherence, as revealed by the finger-tapping task. (2) Changes in respiration rate and/or heart rate acted as relevant contributors to enhanced coherence, as revealed by the hyperventilation task. (3) Working memory performance did not induce changes in coherence, (4) whereas risk-taking behavior was a significant contributor to enhanced coherence. (5) Based on all four tasks, we also observed that coherence may be subject to habituation or sensitization effects over the trial-to-trial course of a task. Increased fNIRS-EDA coherence may be an indicator of a psychophysiological link between the underlying cortical and peripheral affective systems. Our findings are relevant for several neuroscientific research areas seeking to evaluate the interplay between cortical and peripheral affective performance.
    Behavioural Brain Research 08/2014; 270:95–107. DOI:10.1016/j.bbr.2014.04.056 · 3.03 Impact Factor
  • Source
    • "Therefore, in the first instance only comparisons of our study with those involving frontal anagram-evoked stimulation and activation in healthy adults would seem judicious [24,27,28,42–44]. Furthermore, because participants in the present study were subjected to an unusually prolonged task, only studies with similar task duration are considered in the comparison [24,27,28]. In this context, the time to-peak-response found in the present study is of the same order of magnitude as reported in other studies (~1 min), albeit longer. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Using transcranial near-infrared spectroscopy (NIRS) to measure changes in the redox state of cerebral cytochrome c oxidase (Δ[oxCCO]) during functional activation in healthy adults is hampered by instrumentation and algorithm issues. This study reports the Δ[oxCCO] response measured in such a setting and investigates possible confounders of this measurement. Continuous frontal lobe NIRS measurements were collected from 11 healthy volunteers during a 6-minute anagram-solving task, using a hybrid optical spectrometer (pHOS) that combines multi-distance frequency and broadband components. Only data sets showing a hemodynamic response consistent with functional activation were interrogated for a Δ[oxCCO] response. Simultaneous systemic monitoring data were also available. Possible influences on the Δ[oxCCO] response were systematically investigated and there was no effect of: 1) wavelength range chosen for fitting the measured attenuation spectra; 2) constant or measured, with the pHOS in real-time, differential pathlength factor; 3) systemic hemodynamic changes during functional activation; 4) changes in optical scattering during functional activation. The Δ[oxCCO] response measured in the presence of functional activation was heterogeneous, with the majority of subjects showing significant increase in oxidation, but others having a decrease. We conclude that the heterogeneity in the Δ[oxCCO] response is physiological and not induced by confounding factors in the measurements.
    Biomedical Optics Express 10/2012; 3(10):2550-66. DOI:10.1364/BOE.3.002550 · 3.65 Impact Factor
Show more