Parallel spectroscopic imaging reconstruction with arbitrary trajectories using k-space sparse matrices.

Lucas Center for MR Spectroscopy and Imaging, Department of Radiology, Stanford University, Stanford, California 94305-5488, USA.
Magnetic Resonance in Medicine (Impact Factor: 3.4). 02/2009; 61(2):267-72. DOI: 10.1002/mrm.21838
Source: PubMed

ABSTRACT Parallel imaging reconstruction has been successfully applied to magnetic resonance spectroscopic imaging (MRSI) to reduce scan times. For undersampled k-space data on a Cartesian grid, the reconstruction can be achieved in image domain using a sensitivity encoding (SENSE) algorithm for each spectral data point. Alternative methods for reconstruction with undersampled Cartesian k-space data are the SMASH and GRAPPA algorithms that do the reconstruction in the k-space domain. To reconstruct undersampled MRSI data with arbitrary k-space trajectories, image-domain-based iterative SENSE algorithm has been applied at the cost of long computing times. In this paper, a new k-space domain-based parallel spectroscopic imaging reconstruction with arbitrary k-space trajectories using k-space sparse matrices is applied to MRSI with spiral k-space trajectories. The algorithm achieves MRSI reconstruction with reduced memory requirements and computing times. The results are demonstrated in both phantom and in vivo studies. Spectroscopic images very similar to that reconstructed with fully sampled spiral k-space data are obtained at different reduction factors.

Download full-text

Full-text

Available from: Daniel M Spielman, Oct 01, 2014
0 Followers
 · 
98 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: In this paper we propose an efficient sparse reconstruction scheme for the parallel MRSI data acquired using a fast spiral scheme. We model the system using the MR priors estimated from the water reference scan. In our sparse reconstruction approach, we minimize the total variation and ℓ<sub>1</sub> norm of the compartmentalized MRSI data in order to reduce noise, inhomogeneity distortions, and spectral leakage. We demonstrate significant improvement for in vivo brain results when compared to classical regularized SENSE MRSI reconstruction.
    Proceedings of the 8th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2011, March 30 - April 2, 2011, Chicago, Illinois, USA; 01/2011
  • [Show abstract] [Hide abstract]
    ABSTRACT: PURPOSE: To validate the reproducibility of a chemical shift imaging (CSI) acquisition protocol with parallel imaging, using automated repositioning software. MATERIALS AND METHODS: Ten volunteers were imaged three times on two different 3 Tesla (T) MRI scanners, receiving anatomical imaging and two identical CSI measurements, using automated repositioning software for consistent repositioning of the CSI grid. Offcenter parameters of the CSI plane were analyzed. Coefficients of variation (CoV), Cramér-Rao lower bounds (CRLB), intraclass correlation coefficients (ICC), and coefficients of repeatability (CoR) for immediate repetition and between scanners were calculated for N-acetylaspartate, total choline, creatine, myo-inositol (Myo) and glutamine+glutamate (Glx). Proportions of variance reflecting the effect of voxel location, volunteer, repetition, time instance and scanner were calculated from an analysis of variance analysis. RESULTS: The offcenter vector and angulations of the CSI grid differed less than 1 mm and 2° between all measurements. The mean CoV and CRLB were less than 30% for all metabolites, except for Myo. The variance due to voxel location in the volume of interest and the error represent the largest contributions in variability. The ICC is the lowest for Myo and Glx. CoR for immediate repetition and between scanners display values between 22 and 83%. CONCLUSION: We propose a CSI protocol with acceptable reproducibility, applicable in clinical routine. J. Magn. Reson. Imaging 2012;. © 2012 Wiley Periodicals, Inc.
    Journal of Magnetic Resonance Imaging 02/2013; 37(2). DOI:10.1002/jmri.23820 · 2.79 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: PURPOSE: To assess the impact of accelerated acquisitions on the spectral quality of volumetric magnetic resonance spectroscopic imaging (MRSI) and to evaluate their ability in detecting metabolic changes with mild injury. MATERIALS AND METHODS: The implementation of a generalized autocalibrating partially parallel acquisition (GRAPPA) method for a high-resolution whole-brain echo planar SI (3D-EPSI) sequence is first described and the spectral accuracy of the GRAPPA-EPSI method is investigated using lobar and voxel-based analyses for normal subjects and patients with mild traumatic brain injuries (mTBI). The performance of GRAPPA was compared with that of fully encoded EPSI for five datasets collected from normal subjects at the same scanning session, as well as on 45 scans (20 normal subjects and 25 mTBI patients) for which the reduced k-space sampling was simulated. For comparison, a central k-space lower-resolution 3D-EPSI acquisition was also simulated. Differences in individual metabolites and metabolite ratio distributions of the mTBI group relative to those of age-matched control subjects were statistically evaluated using analyses divided into hemispheric brain lobes and tissue types. RESULTS: GRAPPA-EPSI with 16-minute scan time yielded robust and similar results in terms of MRSI quantitation, spectral fitting, and accuracy with that of fully sampled 3D-EPSI acquisitions and was more accurate than central k-space acquisition. Primary findings included high correlations (accuracy of 92.6%) between the GRAPPA and fully sampled results. CONCLUSION: Although the reduced encoding method is associated with lower signal-to-noise ratio (SNR) that impacts the quality of spectral analysis, the use of the parallel imaging method can lead to the same diagnostic outcomes as the fully sampled data when using the sensitivity-limited volumetric MRSI. J. Magn. Reson. Imaging 2013;. © 2013 Wiley Periodicals, Inc.
    Journal of Magnetic Resonance Imaging 01/2014; 40(4). DOI:10.1002/jmri.24130 · 2.79 Impact Factor