Article

Seismic force demand on ductile reinforced concrete shear walls subjected to western North American ground motions: Part 2 — new capacity design methods

Canadian Journal of Civil Engineering (Impact Factor: 0.47). 06/2012; 39(7):738-750. DOI: 10.1139/l2012-044

ABSTRACT This paper proposes for the Canadian Standards Association (CSA) standard A23.3 new capacity design methods, accounting for higher mode amplification effects, for determining, for a single plastic hinge design, capacity design envelopes for flexural and shear strength design of regular ductile reinforced concrete cantilever walls used as seismic force resisting system for multistorey buildings. The derivation of these methods is based on the outcomes from a review on various capacity design methods proposed in the current literature and recommended by design codes and from the extensive parametric study presented in the companion paper. A discussion on the limitations of the proposed methods and on their applicability to various wall systems is presented.

0 Bookmarks
 · 
77 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: This paper presents an assessment of the seismic performance of a ductile concrete core wall used as a seismic force resisting system for a 12-storey concrete office building in Montréal, designed according to the 2005 National building code of Canada (NBCC) and the 2004 Canadian Standards Association standard A23.3. The core wall consists of a cantilever wall system in one direction and a coupled wall system in the orthogonal direction. The building is analyzed in the nonlinear regime. The main conclusion from this work is that the capacity design shear envelope for the studied wall structure largely underestimates that predicted, primarily in the cantilever wall direction, and this in turn significantly increases the risk of shear failure. This issue is essentially due to (i) an underestimation by the new NBCC spectral response acceleration of the higher mode responses of a reinforced concrete wall structure whose seismic response is dominated by higher modes; and (ii) a deficiency in the capacity design method in estimating the wall shear demand on such walls, even when their behavior is lightly inelastic.Cet article présente une évaluation de la performance sismique d'un système de murs de contreventement ductiles utilisé comme système de résistance aux forces sismiques pour un bâtiment de 12 étages en béton armé dimensionné selon le CNBC 2005 et la Norme CSA A23.3 2004, et situé à Montréal. Le système de murs se comporte comme un mur en cantilever dans une direction et comme un mur couplé dans la direction orthogonale. Le bâtiment est analysé dans le régime non-linéaire. La conclusion principale de ce travail est que l'enveloppe de dimensionnement à la capacité en cisaillement sous-estime largement celle prédite, surtout dans la direction du mur en cantilever, et que ceci en retour augmente significativement le risque de rupture par cisaillement. Ce problème est essentiellement causée par (i) une sous-estimation par l'accélération spectrale du CNBC des réponses des modes supérieurs de vibration d'un mur en béton armé dont la réponse sismique est dominée par les modes supérieurs; et (ii) une déficience de la méthode de dimensionnement à la capacité à estimer la demande en cisaillement sur de tels murs, même lorsque leur comportement est légèrement inélastique.
    Canadian Journal of Civil Engineering 12/2009; 37(1):1-16. · 0.47 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A parametric study of regular ductile reinforced concrete (RC) cantilever walls designed with the 2010 National building code of Canada and the 2004 Canadian Standards Association (CSA) standard A23.3 for Vancouver is performed to investigate the influence of the following parameters on the higher mode amplification effects, and hence on the seismic force demand: number of storeys, fundamental lateral period (T), site class, wall aspect ratio, wall cross-section, and wall base flexural overstrength (γw). The study is based on inelastic time-history analyses performed with a multilayer beam model and a smeared membrane model accounting for inelastic shear–flexure–axial interaction. The main conclusions are that (i) T and γw are the studied parameters affecting the most dynamic shear amplification and seismic force demand, (ii) the 2004 CSA standard A23.3 capacity design methods are inadequate, and (iii) a single plastic hinge design may be inadequate and unsafe for regular ductile RC walls with γw < 2.0.
    Canadian Journal of Civil Engineering 06/2012; 39(7):723-737. · 0.47 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The observed response of medium high-rise buildings during the latest earthquakes in the USA, Chile, Mexico and Japan have indicated that buildings with structural walls or dual systems of frames and walls behave considerably better during strong shaking. A series of strong motion and ambient vibration records have been obtained in a 22-stories high structural wall Chilean building. Dynamic properties and response characteristics are identified using parametric and nonparametric system identification techniques. A strong coupling of translational modes and very low damping values are observed during medium intensity seismic events and ambient excitations. Typical values for critical damping ratios are between 1 and 2%. Rocking is observed as an appreciable effect on the overall displacements of the structure. Torsional effects are not important in the observed seismic response but they become relatively important during low level ambient excitations. The basic response characteristics identified are compared with those of a three-dimensional model. The model was determined using typical consulting office assumptions. The agreement between model and experimental records is good for global dynamic parameters, and with further adjustment, seismic response can be modeled with a good degree of accuracy validating a series of modeling assumptions.
    Engineering Structures. 01/2000;