Bedside optic nerve sheath diameter ultrasound for the evaluation of suspected pediatric ventriculoperitoneal shunt failure in the emergency department

Department of Emergency Medicine, University of California, San Franisco, 505 Parnassus Avenue, Room M24, San Francisco, CA, 94143-0203, USA, .
Child s Nervous System (Impact Factor: 1.11). 06/2013; 29(12). DOI: 10.1007/s00381-013-2172-y
Source: PubMed


To determine the feasibility and test characteristics of optic nerve sheath diameter (ONSD) measured by ocular ultrasound as a screening tool for ventriculoperitoneal shunt (VPS) failure.

Prospective observational study using a convenience sample of children 6 months to 18 years of age, presenting to an academic pediatric emergency department for evaluation of possible VPS failure between September 2008 and March 2009. ONSD was measured by anterior transbulbar and lateral transbulbar techniques. Mean ONSD was compared between subjects with and without shunt failure, as determined by neurosurgical decision to operate.

A total of 39 encounters were completed, including 20 VPS failures. The mean ONSD was 4.5 ± 0.9 and 5.0 ± 0.6 mm among encounters with and without shunt failure (p = 0.03), respectively. The mean ONSD was not statistically different when obtained by the anterior transbulbar vs. the lateral transbulbar approach (4.8 ± 1.0 vs. 4.7 ± 0.8 mm, p = 0.12). ONSD ultrasound had a sensitivity of 61.1 % (95 % CI 35.7-82.7) and specificity of 22.2 % (95 % CI 6.4-47.6 %) for detecting shunt failure in this sample.

ONSD ultrasound does not appear to be a useful primary screening tool in emergency department evaluation of VPS failure. There was no difference between the anterior transbulbar approach and the lateral transbulbar approach. Children with VPS in our sample have larger ONSD measurements than in previously reported studies.


Available from: M. Kennedy Hall, Aug 26, 2014
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Anatomy students are often confused by multiple names ascribed to the same structure by different clinical disciplines. Increasingly, sonography is being incorporated into clinical anatomical education, but ultrasound textbooks often use names unfamiliar to the anatomist. Confusion is worsened when ultrasound names ascribed to the same structure actually refer to different structures. Consider the sonographic main lobar fissure (MLF). The sonographic MLF is a hyper-echoic landmark used by sonographers of the right upper quadrant. Found in approximately 70% of people, there is little consensus on what the sonographic MLF is anatomically. This structure appears to be related to the main portal fissure (aka principal plane of the liver or principal hepatic fissure), initially described by anatomists and surgeons as in intrahepatic division along the middle hepatic vein which in essence divides the territories of the left and right hepatic arteries and biliary systems. By exploring the relationship between the main portal fissure and the sonographic MLF in cadaveric livers ex vivo, the data suggest the sonographic MLF is actually an extrahepatic structure that parallels the rim of the main portal fissure. The authors recommend that this structure be renamed the “sonographic cystic pedicle,” which includes the cystic duct and ensheathing fat and blood vessels. In the context of the redefined underlying anatomy, the absence of the sonographic cystic pedicle due to anatomic variation may serve an important clinical role in predicting complications from difficult laparoscopic cholecystectomies and is deserving of future study. Anat Sci Educ. © 2015 American Association of Anatomists.
    Anatomical Sciences Education 01/2015; 8(3). DOI:10.1002/ase.1518 · 2.98 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The purpose of this study was to investigate the value of the change in optic nerve sheath diameter (ONSD) as a radiological marker of endoscopic third ventriculostomy (ETV) outcome in children. Magnetic resonance imaging (MRI) scans of patients on whom ETVs were performed between the periods of January 2009 and June 2013 were reviewed. ONSD measurements on pre- and post-operative images were performed by two blinded observers, and the relationship between the change in these measurements and outcome from ETV were investigated. These findings were then also compared to conventional imaging features associated with ETV outcome. MRI scans of 24 patients were adequate to measure the ONSD pre- and post-operatively. In patients with successful ETV (n = 19), the mean change in ONSD was 0.73 mm and in patients with a failed ETV (n = 5), the mean change in ONSD was 0.18 mm (p = 0.0007). A change in ONSD of 7.5 % of the initial measurement demonstrated a sensitivity of 92.9 % and a sensitivity of 85.7 % for ETV outcome (area under the receiver operating characteristic curve (AUROC) = 0.96). Change in ONSD is a useful radiological marker of ETV outcome and may be used in combination with conventional radiological parameters to aid decision-making in this difficult group of patients.
    Child s Nervous System 03/2015; 31(5). DOI:10.1007/s00381-015-2655-0 · 1.11 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Ultrasound of cranial nerves is a novel subdomain of neuromuscular ultrasound (NMUS) which may provide additional value in the assessment of cranial nerves in different neuromuscular disorders. Whilst NMUS of peripheral nerves has been studied, NMUS of cranial nerves is considered in its initial stage of research, thus, there is a need to summarize the research results achieved to date. Detailed scanning protocols, which assist in mastery of the techniques, are briefly mentioned in the few reference textbooks available in the field. This review article focuses on ultrasound scanning techniques of the 4 accessible cranial nerves: optic, facial, vagus and spinal accessory nerves. The relevant literatures and potential future applications are discussed.
    Journal of Clinical Neurology 04/2015; 11(2):109-21. DOI:10.3988/jcn.2015.11.2.109 · 1.70 Impact Factor
Show more