Article

Current Methods of Monitoring Radiation Exposure From CT

Department of Radiology, Stony Brook University Medical Center, Stony Brook, New York, USA. Electronic address: .
Journal of the American College of Radiology: JACR (Impact Factor: 2.28). 05/2013; 10(9). DOI: 10.1016/j.jacr.2013.03.002
Source: PubMed

ABSTRACT Increased public and regulatory scrutiny of imaging-related radiation exposure requires familiarity with current dose-monitoring techniques and best practices. CT-related ionizing radiation exposure has been cited as the largest and fastest growing source of population-wide iatrogenic ionizing radiation exposure. Upcoming federal regulations require imaging centers to familiarize themselves with available dose-monitoring techniques and implement comprehensive strategies to track patient dose, with particular emphasis on CT. Because of institution-specific and vendor-specific technologies, there are significant barriers to adoption and implementation. In this article, the authors outline the core components of a universal dose-monitoring strategy and detail a few of the many available commercial platforms. In addition, the authors introduce a cloud-based hybrid model dose-tracking system with the goal of rapid implementation, multicenter scalability, real-time dose feedback for technologists, cumulative dose monitoring, and optional dose communication to patients and into the record; doing so results in improved patient loyalty, referring physician satisfaction, and opportunity for repeat business.

1 Follower
 · 
124 Views
 · 
0 Downloads
  • [Show abstract] [Hide abstract]
    ABSTRACT: Implementation of a comprehensive CT radiation dose reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose reduction program, and discuss use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and dose reduction techniques, showing how an understanding of each technique is important in effective auditing of “outlier” doses identified by dose tracking.
    Seminars in Ultrasound CT and MRI 08/2014; 35(4). DOI:10.1053/j.sult.2014.05.004 · 1.08 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality management and improvement program can be built, followed by a discussion of common as well as pediatric-specific challenges. Organizational elements of a CT quality management and improvement program include the formulation of clear objectives; definition of the roles and responsibilities of key personnel; implementation of a technologist training, coaching and feedback program; and use of an efficient and accurate monitoring system. Key personnel and roles include a radiologist as the CT director, a qualified CT medical physicist, as well as technologists with specific responsibilities and adequate time dedicated to operation management, CT protocol management and CT technologist education. Common challenges in managing a clinical CT operation are related to the complexity of newly introduced technology, of training and communication and of performance monitoring. Challenges specific to pediatric patients include the importance of including patient size in protocol and dose considerations, a lower tolerance for error in these patients, and a smaller sample size from which to learn and improve.
    Pediatric Radiology 10/2014; 44(Supplement 3):519-524. DOI:10.1007/s00247-014-3039-4 · 1.65 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: To perform a systematic, large-scale analysis using the Digital Imaging and Communication in Medicine structured report (DICOM-SR) to assess the relationship between body mass index (BMI) and radiation exposure in abdominal CT. A retrospective analysis of DICOM-SR of 3121 abdominal CT examinations between April 2013 and March 2014 was performed. All examinations were conducted using a 128 row CT system. Patients (mean age 61 ± 15 years) were divided into five groups according to their BMI: group A <20 kg/m(2) (underweight), group B 20-25 kg/m(2) (normal weight), group C 25-30 kg/m(2) (overweight), group D 30-35 kg/m(2) (obese), and group E > 35 kg/m(2) (extremely obese). CT dose index (CTDIvol) and dose-length product (DLP) were compared between all groups and matched to national diagnostic reference values. The mean CTDIvol and DLP were 5.4 ± 2.9 mGy and 243 ± 153 mGy·cm in group A, 6 ± 3.6 mGy and 264 ± 179 mGy•cm in group B, 7 ± 3.6 mGy and 320 ± 180 mGy•cm in group C, 8.1 ± 5.2 mGy and 375 ± 306 mGy•cm in group D, and 10 ± 8 mGy and 476 ± 403 mGy•cm in group E, respectively. Except for group A versus group B, CTDIvol and DLP differed significantly between all groups (p<0.05). Significantly more CTDIvol values exceeded national diagnostic reference values in groups D and E (2.1% and 6.3%) compared to group B (0.5%, p<0.05). DICOM-SR is a comprehensive, fast, and reproducible way to analyse dose-related data at CT. It allows for automated evaluation of radiation dose in a large study population. Dose exposition is related to the patient's BMI and is increased by up to 96% for extremely obese patients undergoing abdominal CT. Copyright © 2014. Published by Elsevier Ltd.
    Clinical Radiology 12/2014; 70(2). DOI:10.1016/j.crad.2014.11.002 · 1.66 Impact Factor