Haptically guided robotic technology in total hip arthroplasty: a cadaveric investigation. Proc Inst Mech Eng H

Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York 10021, USA.
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine (Impact Factor: 1.33). 03/2013; 227(3):302-9. DOI: 10.1177/0954411912468540
Source: PubMed


The longevity of total hip arthroplasty (THA) continues to improve with advancements in design and bearing materials. However, the incidence of dislocation and impingement-related failures continue to rise, with the inability of the surgeon to achieve optimal component orientation cited as a cause. Computer-assistance has been shown to increase the accuracy of component orientation and robotic-assistance has been developed to translate this advantage into precise surgical execution. We sought to validate a haptically-guided robotic arm system in performing THA with the aim of comparing the accuracy of robotic-assisted acetabular cup placement to manual placement. We implanted 12 acetabular components in 6 cadaveric pelvises comparing robotic-assistance on one side with manual implantation on the other. We measured planned and actual center of rotation (COR), cup position, leg-length equalization and offset for each THA using computed tomography and the robotic platform. The root-mean-square (RMS) error for the robotic-assisted system was within 3 degrees for cup placement and within 1 mm for leg-length equalization and offset when compared to computed tomography. The robotic-assisted system was significantly more accurate than manual implantation in reproducing the COR and cup orientation, as determined by a preoperative plan. The RMS error for manual implantation compared to robotic-assistance was 5 times higher for cup inclination and 3.4 times higher for cup anteversion (p < 0.01). Robotic-assistance is more accurate than manual implantation in achieving optimal cup orientation. It has the ability to eliminate human error from THA and should be considered in light of THA failures due to component malposition.

55 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: Recent studies suggest the ‘Lewinnek safe zone’ for acetabular component position is outdated. We used a large prospective institutional registry to determine if there is a ‘safe zone’ exists for acetabular component position within which the risk of hip dislocation is low and if other patient and implant factors affect the risk of hip dislocation. Patients who reported a dislocation event within six months after hip replacement surgery were identified, and acetabular component position was measured with anteroposterior radiographs. The frequency of dislocation was 2.1% (147 of 7040 patients). No significant difference was found in the number of dislocated hips among the zones. Dislocators < 50 years old were less active preoperatively than nondislocators (p = 0.006). Acetabular component position alone is not protective against instability.
    The Journal of Arthroplasty 07/2014; 30(1). DOI:10.1016/j.arth.2014.07.009 · 2.67 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: There are no reports examining the learning curve during the adoption of robotic assisted THA. The purpose of this study was to examine the learning curve of robotic assisted THA as measured by component position, operative time, and complications. The first 105 robotic-assisted THAs performed by a single surgeon were divided into three groups based on the order of surgery. Component position, operative time, intra-operative technical problems, and intra-operative complications were recorded. There was a decreased risk of acetabular component malpositioning with experience (p < 0.05). Operative time appeared to decrease with increasing surgical experience (p < 0.05). A learning curve was observed, as a decreased incidence of acetabular component outliers and decreased operative time were noted with increased experience.
    The Journal of Arthroplasty 08/2014; 30(1). DOI:10.1016/j.arth.2014.08.003 · 2.67 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Modern total hip replacement is typically effective and durable, but early failures do occur. Component position influences functional outcome, durability, and risk of complications. Surgical robotics provides the detail-oriented surgeon with a robust tool to optimize the accuracy and precision of total hip arthroplasty, with the potential to minimize risk of mechanical failure. This article describes efficient workflows for using surgical robotics to optimize surgical precision without increasing surgical complexity.
    Orthopedic Clinics of North America 10/2014; 45(4). DOI:10.1016/j.ocl.2014.06.003 · 1.25 Impact Factor