Article

An efficient and selective flourescent optode membrane based on 7-[(5-chloro-8-hydroxy-7-quinolinyl)methyl]-5,6,7,8,9,10-hexahydro-2H-1, 13,4,7,10-benzodioxatriazacyclopentadecine-3,11(4H,12H)-dione as a novel fluoroionophore for determination of cobalt(II) ions

Department of Chemistry, Razi University, Kermanshah, Iran.
Analytica chimica acta (Impact Factor: 4.52). 01/2009; 630(1):57-66. DOI: 10.1016/j.aca.2008.09.051
Source: PubMed

ABSTRACT A novel fluorescence chemical sensor for the highly sensitive and selective determination of Co(2+) ions in aqueous solutions is prepared. The cobalt sensing system was prepared by incorporating 7-[(5-chloro-8-hydroxy-7-quinolinyl)methyl]-5,6,7,8,9,10-hexahydro-2H-1,13,4,7,10-benzodioxatriazacyclopentadecine-3,11(4H,12H)-dione (L) as a neutral cobalt-selective fluoroionophore in the plasticized PVC membrane containing sodium tetraphenylborate as a liphophilic anionic additive. The response of the sensor is based on the strong selective fluorescence quenching of L by Co(2+) ions. At a pH 5.0, the proposed sensor displays a calibration curve over a wide concentration range of 5.0 x 10(-7) to 2.0 x 10(-2)M with a relatively fast response time of less than 5 min. In addition to high stability and reproducibility, the sensor shows a unique selectivity towards Co(2+) ion with respect to common coexisting cations. The proposed fluorescence optode was successfully applied to the determination of cobalt content of vitamin B12 ampoule, cobalt cake, cobalt alloy and tap water samples.

0 Followers
 · 
214 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: The literature on the use of fluorescent sensors for the trace-level determination of toxic cations is highly significant. Among different analytical methods, fluorescence is the most attractive due to its robustness, high sensitivity, selectivity, rapidity, ease of measurement and non-destructive methodology. Here, we illustrate different fluorescent probes developed for detection and estimation of toxic cations, including their molecular structure, sensing mechanism, analytical figures of merit and their applications. We provide a critical survey of the fluorescent sensors of each toxic element (i.e. Hg, Ag, Cd, Cr, Pb, Tl, Co and Ni). A separate section contains the sensors that can detect several toxic elements simultaneously, so-called multi-element sensors. We briefly describe the merits and the demerits of the methods. Finally, we outline future prospects in this field.
    TrAC Trends in Analytical Chemistry 02/2012; 32:113-132. DOI:10.1016/j.trac.2011.08.010 · 6.61 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A new fluorescent sensor for the highly sensitive and selective determination of La3+ ion is developed. The sensing membrane was prepared by incorporating N,N′-bis(dansylamidoethyl)-N,N′-bis(2-pyridylmethyl)propylenediamine (L) as fluoroionophore in the plasticized PVC membrane containing o-NPOE as plasticizer. The proposed sensor displays a wide calibration range of 5.0 × 10−9 to 5.0 × 10−4 M with a low limit of detection of 2.0 × 10−9 M in a solution of pH 6.0. This sensor has a relatively fast response time of less than 2 min. In addition to high stability and reproducibility, it shows a unique selectivity toward La3+ ion with respect to common coexisting cations. The sensor can be regenerated by exposure to a solution of EDTA. The proposed sensor was successfully applied to the determination of La3+ in aqueous solutions.
    Sensors and Actuators 03/2014; B 192:378. DOI:10.1016/j.snb.2013.10.132
  • [Show abstract] [Hide abstract]
    ABSTRACT: In the present study an easy micellar precipitation process at ambient temperature using cationic surfactant cetyl-trimethyl ammonium bromide (CTAB) was applied to the simultaneous extraction of cadmium, cobalt and nickel from aqueous samples. The analytical procedure involved the complex formation of these cations with 1,8-dihydroxyanthrone as a chelating agent in buffer media of pH 7.0. After the phase separation, the precipitated complexes were first dissolved in 025 mL of 80:20 propanol-water mixture containing 0.03 mL HNO(3) and then subjected to the inductively coupled plasma-optical emission spectrometry (ICP-OES) analysis. The concentration of 1,8-dihydroxyanthrone, pH, amount of CTAB and centrifuge time was optimized. Under the optimum conditions, the preconcentration factor was 40 and the improvement factors of 11.6, 9.5 and 14.4 with detection limits of 0.008, 0.009 and 0.004 (ng mL(-1)) were obtained for Cd, Co and Ni respectively. Under the presence of foreign ions no significant interference was observed. Finally, the proposed extraction method was successfully applied to the determination of these elements in various water and geological CRM samples with recovery percentages of 97-104% and RSD values of 1.87-236%.
    Microchemical Journal 01/2012; 100:66-71. DOI:10.1016/j.microc.2011.09.003 · 3.58 Impact Factor