Clinical diagnosis of sleep apnea based on single night of polysomnography vs. two nights of polysomnography.

Sleep Research Unit, Toronto Western Research Institute, University Health Network, ON, Canada.
Sleep And Breathing (Impact Factor: 2.26). 01/2009; 13(3):221-6. DOI: 10.1007/s11325-008-0234-2
Source: PubMed

ABSTRACT The purpose of this study was to investigate apnea-hypopnea index (AHI) across two polysomnographies (PSGs) to examine AHI variability and impact on clinical diagnosis.
Two-night PSGs of 193 sleep clinic patients were reviewed, and the AHI variability was analyzed. Anonymized records from five patients with significant night-to-night AHI variability were used in this study: the two-night PSGs from two patients were represented as four individual PSGs; the two-night PSG for two others were represented as being obtained from two different sleep clinics; the last patient's PSG was shown as a two-night study. Twenty-two sleep experts attending the Associated Professional Sleep Societies meeting were recruited to make diagnoses based on the PSGs. They were told that the PSGs were from seven patients: four with single-night PSG; two with two PSGs, each one from a different clinic; and one patient with a two-night PSG.
Twenty-one percent of the 193 sleep clinic patients had a nightly PSG AHI variability of greater than 5. Forty-eight percent of all patients had a significantly higher AHI on the first night, and 41% had a significantly higher AHI on the second night. Using an AHI > 15 diagnostic criteria, sleep apnea would have been undetected in 20% (n = 39) of patients due to low AHI on one night. Furthermore, 13% of all patients had a more severe sleep apnea classification based on the second night of PSG. For the seven cases, 27-36% of sleep experts failed to identify sleep apnea especially when presented with the PSG containing the lower AHI. Incidences of missed sleep apnea diagnoses were reduced to 15-18% when information from two PSGs was presented to the sleep experts.
Utilizing a large patient population, this study supports the significant night-to-night variability in PSG respiratory variables. Identification of sleep apnea in some patients is reduced when sleep experts are provided with only one PSG recording. The clinical implication is that about 13% of sleep clinic patients might benefit from a second night of PSG.

1 Bookmark
 · 
126 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Purpose More than half of patients with chronic obstructive pulmonary disease (COPD) experiences sleep-related problems and about one fourth uses hypnotics regularly. We explored what the effect zopiclone, a commonly used hypnotic, had on nocturnal gas exchange and the apnea/hypopnea frequency in stable COPD. Methods Randomized crossover study of 31 (ten males) inpatients at a pulmonary rehabilitation hospital, median age 64 years, of which 20 had a forced expiratory volume first second tcCO2). Results Zopiclone increased the mean ΔPtcCO2 from baseline both in rapid eye movement (REM) sleep, non-REM sleep, and even in stage N0 (awake after sleep onset) with a mean (SD) of 0.25 (0.40) kPa, 0.22 (0.32) kPa, and 0.14 (0.27) kPa, respectively. Subjects with sleep hypoventilation as defined by the American Academy of Sleep Medicine increased from 6 subjects (19 %) to 13 subjects (42 %) (P = 0.020). REM sleep minimum oxygen saturation (minSpO2) did not change significantly from baseline median (interquartile range [IQR]) minSpO2 81.8 (12.1) % to zopiclone sleep median (IQR) minSpO2 80.0 (12.0) % (P = 0.766). Interestingly, zopiclone reduced the number of apneas/hypopneas per hour (AHI) in subjects with overlap (AHI ≥ 15) with a median difference (IQR) of −8.5 (7.8) (N = 11, P = 0.016). Conclusions In stable COPD, zopiclone moderately increases the mean ΔPtcCO2 without changing minSpO2 at night and reduces AHI in overlap (COPD and obstructive sleep apnea) subjects.
    Sleep And Breathing 12/2014; DOI:10.1007/s11325-014-1084-8 · 2.87 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The prevalence of obstructive sleep apnea (OSA) has been steadily rising over recent decades and patient access to laboratory-based sleep services and specialist consultations have become increasingly limited, resulting in potential delays in treatment. As a result, there has been growing interest in the use of non-sleep laboratory methods for diagnosing and managing OSA, including the use of screening questionnaires, portable sleep monitoring devices, and home autotitrating continuous positive airway pressure. There is also evidence in support of a role for alternative health care professionals, such as sleep-trained nurses and primary care physicians in the diagnosis and treatment of OSA. In this review, we compare the different types of home monitoring devices, discuss the limitations of portable monitoring compared with full laboratory polysomnography, and summarize the results from published comparative effectiveness studies which have evaluated ambulatory models of care for the management of OSA. We also consider how future models of care that may be needed to deal with the burden of disease will evolve and some of the issues that prevent the translation of such models of care in many countries.
    Seminars in Respiratory and Critical Care Medicine 10/2014; 35(5):545-51. DOI:10.1055/s-0034-1390139 · 2.75 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: In this paper, an algorithm to extract respiration signals using a flexible projected capacitive sensing mattress (FPCSM) designed for personal health assessment is proposed. Unlike the interfaces of conventional measurement systems for poly-somnography (PSG) and other alternative contemporary systems, the proposed FPCSM uses projected capacitive sensing capability that is not worn or attached to the body. The FPCSM is composed of a multi-electrode sensor array that can not only observe gestures and motion behaviors, but also enables the FPCSM to function as a respiration monitor during sleep using the proposed approach. To improve long-term monitoring when body movement is possible, the FPCSM enables the selection of data from the sensing array, and the FPCSM methodology selects the electrodes with the optimal signals after the application of a channel reduction algorithm that counts the reversals in the capacitive sensing signals as a quality indicator. The simple algorithm is implemented in the time domain. The FPCSM system is used in experimental tests and is simultaneously compared with a commercial PSG system for verification. Multiple synchronous measurements are performed from different locations of body contact, and parallel data sets are collected. The experimental comparison yields a correlation coefficient of 0.88 between FPCSM and PSG, demonstrating the feasibility of the system design.
    Sensors 11/2014; 14(11):22021-38. DOI:10.3390/s141122021 · 2.05 Impact Factor

Full-text (2 Sources)

Download
12 Downloads
Available from
Oct 16, 2014