Sperm Trajectories Form Chiral Ribbons

1] Electrical Engineering Department, University of California, Los Angeles, CA, 90095, USA [2] Bioengineering Department, University of California, Los Angeles, CA, 90095, USA.
Scientific Reports (Impact Factor: 5.58). 04/2013; 3:1664. DOI: 10.1038/srep01664
Source: PubMed


We report the discovery of an entirely new three-dimensional (3D) swimming pattern observed in human and horse sperms. This motion is in the form of 'chiral ribbons', where the planar swing of the sperm head occurs on an osculating plane creating in some cases a helical ribbon and in some others a twisted ribbon. The latter, i.e., the twisted ribbon trajectory, also defines a minimal surface, exhibiting zero mean curvature for all the points on its surface. These chiral ribbon swimming patterns cannot be represented or understood by already known patterns of sperms or other micro-swimmers. The discovery of these unique patterns is enabled by holographic on-chip imaging of >33,700 sperm trajectories at >90-140 frames/sec, which revealed that only ~1.7% of human sperms exhibit chiral ribbons, whereas it increases to ~27.3% for horse sperms. These results might shed more light onto the statistics and biophysics of various micro-swimmers' 3D motion.

1 Follower
26 Reads
  • Source
    • "Accordingly, the FOV of lensfree on-chip microscopy is significantly wider than the FOV of a lens-based transmission microscope that has a similar resolution level [32], [37]. An additional advantage of these holographic on-chip microscopes is that the recorded image can be digitally focused to different depths, thus allowing screening of large sample volumes [38]–[40]. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Based on partially-coherent digital in-line holography, we report a field-portable microscope that can render lensfree colour images over a wide field-of-view of e.g., >20 mm(2). This computational holographic microscope weighs less than 145 grams with dimensions smaller than 17×6×5 cm, making it especially suitable for field settings and point-of-care use. In this lensfree imaging design, we merged a colorization algorithm with a source shifting based multi-height pixel super-resolution technique to mitigate 'rainbow' like colour artefacts that are typical in holographic imaging. This image processing scheme is based on transforming the colour components of an RGB image into YUV colour space, which separates colour information from brightness component of an image. The resolution of our super-resolution colour microscope was characterized using a USAF test chart to confirm sub-micron spatial resolution, even for reconstructions that employ multi-height phase recovery to handle dense and connected objects. To further demonstrate the performance of this colour microscope Papanicolaou (Pap) smears were also successfully imaged. This field-portable and wide-field computational colour microscope could be useful for tele-medicine applications in resource poor settings.
    PLoS ONE 09/2013; 8(9):e76475. DOI:10.1371/journal.pone.0076475 · 3.23 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: We report a field-portable lensfree on-chip holographic microscope that can image confluent color samples, with sub-micron resolution over a wide field-of-view (FOV) of ∼ 20 mm2. This color microscope is suitable for field use as it weighs less than 150 grams and its dimensions are smaller than 17×6×5 cm3. The unique design of this lensfree microscope utilizes three computational methods, namely: (i) pixel super-resolution to achieve sub-micron resolution with unit magnification over a large FOV, (ii) multi-height phase-recovery that enables imaging of confluent samples, and (iii) YUV color space averaging that mitigates ‘rainbow’ like color artifacts, typically observed in holographic imaging. To demonstrate the performance of our computational color microscope, we imaged a 1951 USAF test chart and Papanicolaou (Pap) smear samples. This holographic color microscope with its light-weight, cost-effective design, and wide FOV could be useful for tele-pathology applications including for example diagnosis of cervical cancer or malaria.
    Global Humanitarian Technology Conference (GHTC), 2013 IEEE; 10/2013
  • [Show abstract] [Hide abstract]
    ABSTRACT: Computer-assisted sperm analysis (CASA) systems have evolved over approximately 40 years, through advances in devices to capture the image from a microscope, huge increases in computational power concurrent with amazing reduction in size of computers, new computer languages, and updated/expanded software algorithms. Remarkably, basic concepts for identifying sperm and their motion patterns are little changed. Older and slower systems remain in use. Most major spermatology laboratories and semen processing facilities have a CASA system, but the extent of reliance thereon ranges widely. This review describes capabilities and limitations of present CASA technology used with boar, bull, and stallion sperm, followed by possible future developments. Each marketed system is different. Modern CASA systems can automatically view multiple fields in a shallow specimen chamber to capture strobe-like images of 500 to >2000 sperm, at 50 or 60 frames per second, in clear or complex extenders, and in <2 minutes, store information for ≥30 frames and provide summary data for each spermatozoon and the population. A few systems evaluate sperm morphology concurrent with motion. CASA cannot accurately predict ‘fertility’ that will be obtained with a semen sample or subject. However, when carefully validated, current CASA systems provide information important for quality assurance of semen planned for marketing, and for the understanding of the diversity of sperm responses to changes in the microenvironment in research. The four take-home messages from this review are: (1) animal species, extender or medium, specimen chamber, intensity of illumination, imaging hardware and software, instrument settings, technician, etc., all affect accuracy and precision of output values; (2) semen production facilities probably do not need a substantially different CASA system whereas biology laboratories would benefit from systems capable of imaging and tracking sperm in deep chambers for a flexible period of time; (3) software should enable grouping of individual sperm based on one or more attributes so outputs reflect subpopulations or clusters of similar sperm with unique properties; means or medians for the total population are insufficient; and (4) a field-use, portable CASA system for measuring one motion and two or three morphology attributes of individual sperm is needed for field theriogenologists or andrologists working with human sperm outside urban centers; appropriate hardware to capture images and process data apparently are available.
    Theriogenology 01/2014; 81(1):5–17.e3. DOI:10.1016/j.theriogenology.2013.09.004 · 1.80 Impact Factor
Show more


26 Reads
Available from