In vivo optical trapping indicates kinesin’s stall force is reduced by dynein during intracellular transport

Physics Department and Center for Physics of the Living Cell, University of Illinois at Urbana-Champaign, Urbana, IL 61801.
Proceedings of the National Academy of Sciences (Impact Factor: 9.67). 02/2013; 110(9):3381-6. DOI: 10.1073/pnas.1219961110
Source: PubMed


Kinesin and dynein are fundamental components of intracellular transport, but their interactions when simultaneously present on cargos are unknown. We built an optical trap that can be calibrated in vivo during data acquisition for each individual cargo to measure forces in living cells. Comparing directional stall forces in vivo and in vitro, we found evidence that cytoplasmic dynein is active during minus- and plus-end directed motion, whereas kinesin is only active in the plus direction. In vivo, we found outward (∼plus-end) stall forces range from 2 to 7 pN, which is significantly less than the 5- to 7-pN stall force measured in vitro for single kinesin molecules. In vitro measurements on beads with kinesin-1 and dynein bound revealed a similar distribution, implying that an interaction between opposite polarity motors causes this difference. Finally, inward (∼minus-end) stalls in vivo were 2-3 pN, which is higher than the 1.1-pN stall force of a single dynein, implying multiple active dynein.

Full-text preview

Available from:
  • Source
    • "The GDI is imagined as a water pump which could be involved in intracellular MT transport. There is evidence that ATP-driven motor proteins such as dynein and kinesin are involved in MT transport cargo (Blehm et al., 2013). However, in these conditions, the vesicle membrane and the MT surface are very close each other. "
    [Show abstract] [Hide abstract]
    ABSTRACT: The current cell oxygen paradigm shows some major gaps that have not yet been resolved. Something seems to be lacking for the comprehensive statement of the oxygen distribution in the cell, especially the low cytoplasmic oxygen level. The entrapment of oxygen in microtubules (MTs) resolves the latter observation, as well as the occurrence of an extensive cytoplasmic foam formation. It leads to a novel oxygen paradigm for cells. During the steady-state treadmilling, the mobile cavity would absorb oxygenated cytoplasm forward, entrap gas nuclei and concentrate them. A fluorescence method is described to confirm the in vitro load of oxygen in MTs during their periodic growths and shrinkages. The latter operating mechanism is called the gas dynamic instability (GDI) of MTs.
    Bio Systems 04/2014; 118(1). DOI:10.1016/j.biosystems.2014.01.008 · 1.55 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Specific subsets of biochemical reactions in eukaryotic cells are restricted to individual membrane compartments, or organelles. Cells, therefore, face the monumental task of moving the products of those reactions between individual organelles. Because of the high density of the cytoplasm and the large size of membrane organelles, simple diffusion is grossly insufficient for this task. Proper trafficking between membrane organelles thus relies on cytoskeletal elements and the activity of motor proteins, that act both in transport of membrane compartments and as tethering agents to ensure their proper distribution and to facilitate organelle interactions.
    Current opinion in cell biology 03/2013; 25(4). DOI:10.1016/ · 8.47 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: With the success of in vitro single-molecule force measurements obtained in recent years, the next step is to perform quantitative force measurements inside a living cell. Optical traps have proven excellent tools for manipulation, also in vivo, where they can be essentially non-invasive under correct wavelength and exposure conditions. It is a pre-requisite for in vivo quantitative force measurements that a precise and reliable force calibration of the tweezers is performed. There are well-established calibration protocols in purely viscous environments; however, as the cellular cytoplasm is viscoelastic, it would be incorrect to use a calibration procedure relying on a viscous environment. Here we demonstrate a method to perform a correct force calibration inside a living cell. This method (theoretically proposed in Fischer and Berg-Sørensen (2007 J. Opt. A: Pure Appl. Opt. 9 S239)) takes into account the viscoelastic properties of the cytoplasm and relies on a combination of active and passive recordings of the motion of the cytoplasmic object of interest. The calibration procedure allows us to extract absolute values for the viscoelastic moduli of the living cell cytoplasm as well as the force constant describing the optical trap, thus paving the way for quantitative force measurements inside the living cell. Here, we determine both the spring constant of the optical trap and the elastic contribution from the cytoplasm, influencing the motion of naturally occurring tracer particles. The viscoelastic moduli that we find are of the same order of magnitude as moduli found in other cell types by alternative methods.
    Physical Biology 07/2013; 10(4):046006. DOI:10.1088/1478-3975/10/4/046006 · 2.54 Impact Factor
Show more