Article

Best Face Forward: Virtual Modeling and Custom Device Fabrication to Optimize Craniofacial Vascularized Composite Allotransplantation

New York, N.Y.
Plastic and Reconstructive Surgery (Impact Factor: 3.33). 01/2013; 131(1):64-70. DOI: 10.1097/PRS.0b013e3182729ef0
Source: PubMed

ABSTRACT Craniofacial vascularized composite allotransplantation is especially challenging when bony components are required. Matching the complex three-dimensional anatomy of the donor and recipient craniofacial skeletons to optimize bony contact and dental occlusion is a time-consuming step in the operating room. Currently, few tools exist to facilitate this process. The authors describe the development of a virtual planning protocol and patient-specific device design to efficiently match the donor and recipient skeletal elements in craniofacial vascularized composite allotransplantation. The protocol was validated in a cadaveric transplant. This innovative planning method allows a "snap-fit" reconstruction using custom surgical guides while maintaining facial height and width and functional occlusion. Postoperative overlay technology in the virtual environment provides an objective outcome analysis.

0 Followers
 · 
75 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Full facial osteomyocutaneous transplantation requires correct 3-dimensional (3D) alignment of donor osseous structures to a new cranial base with minimal reference points and 6 degrees of potential movement. We investigated whether computer-assisted design and manufacturing (CAD/CAM) could enable accurate placement of the facial skeleton. A prospective single-cohort study of Le Fort III-based maxillary-mandibular segment allotransplantation was performed in 5 cadaver pairs and 1 clinical pair. The osteotomies were modeled using computed tomography (CT) data and 3D modeling software and then translated to the donor-recipient pairs using surgical navigation and osteotomy cutting guides. The predicted values were calculated about all rotational axes (pitch, yaw, and roll) and along all translational axes (vertical, horizontal, and anteroposterior) and used as the independent variable. The primary outcome variable of the actual postoperative CT values was compared for fidelity to the prediction using the intraclass correlation coefficient (ICC). The similarity to the donor versus recipient values was calculated as a secondary independent variable, and both predicted and actual measurements were compared with it as a percentage. The postoperative fidelity to the plan was adequate to excellent (ICC 0.520 to 0.975) with the exception of lateral translation (2.94 ± 1.31 mm predicted left vs 3.92 ± 2.17 mm right actual displacement; ICC 0.243). The predicted and actual values were not consistently skewed toward the donor or recipient values. We have demonstrated a novel application of CAD/CAM that enables orthognathic alignment of a maxillary-mandibular segment to a new cranial base. Quantification of the alignment in all 6 degrees of freedom delivers precise control compared with the planned changes and allows postoperative quality control.
    Journal of oral and maxillofacial surgery: official journal of the American Association of Oral and Maxillofacial Surgeons 01/2014; DOI:10.1016/j.joms.2014.01.016 · 1.28 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Since the first facial transplantation in 2005, 28 have been done worldwide with encouraging immunological, functional, psychological, and aesthetic outcomes. Unlike solid organ transplantation, which is potentially life-saving, facial transplantation is life-changing. This difference has generated ethical concerns about the exposure of otherwise young and healthy individuals to the sequelae of lifelong, high-dose, multidrug immunosuppression. Nevertheless, advances in immunomodulatory and immunosuppressive protocols, microsurgical techniques, and computer-aided surgical planning have enabled broader clinical application of this procedure to patients. Although episodes of acute skin rejection continue to pose a serious threat to face transplant recipients, all cases have been controlled with conventional immunosuppressive regimens, and no cases of chronic rejection have been reported.
    The Lancet 04/2014; 384(9960). DOI:10.1016/S0140-6736(13)62632-X · 39.21 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Purpose: The purpose of this study was to validate a virtual reality software for the recording of anthropometric measurements as a first step towards matching donors with recipients in the preoperative planning process which precedes the harvest of a facial allograft. Methods: Anthropometric measurements of both soft and bone tissue were recorded in 5 cryopreserved human heads to compare conventional analogue measurements with digital measurements obtained from 3-dimensional (3D) reconstructions produced using AYRA software. To test the degree of correlation between both measuring methods, intraclass correlation coefficient (ICC) was applied to each pair of measurements. Results: ICCs calculated were greater than 0.6 (substantial or almost perfect correlation) for all of the pairs of variables, with the exception of 2 of the measurements studied in bone tissue. Conclusions: In facial transplantation, preoperative planning is crucial to select an allograft whose anatomical compatibility with the recipient defect is as close as possible. The dimensions of the potential face donor must be congruent to ensure the procedure's feasibility and the adequate insertion of the allograft into the defect. The recording of anthropometric measurements with the virtual reality software displayed an equivalent correlation to those produced using a conventional analogue method. The 3D reconstructions obtained by using a virtual reality software can play a useful role to facilitate the characterization of the donor face.
    Journal of Craniofacial Surgery 08/2014; 25(5). DOI:10.1097/SCS.0000000000000989 · 0.68 Impact Factor