Diagnostic Performance of Dark-Blood T2-Weighted CMR for Evaluation of Acute Myocardial Injury

and ‡Department of Radiology, University of Utah, Salt Lake City, UT.
Investigative radiology (Impact Factor: 4.44). 11/2012; 14(Suppl 1). DOI: 10.1097/RLI.0b013e3182718672
Source: PubMed


OBJECTIVES: We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. BACKGROUND: Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. MATERIALS AND METHODS: A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (<30 days) troponin elevation greater than 2 times the upper limit of normal as the reference standard for acute myocardial injury. RESULTS: Of the 65 patients, there were 21 (32%) with acute myocardial injury. Image quality and artifact scores were significantly better with FSE-SPAIR compared with FSE-STIR (2.15 vs 2.68, P < 0.01; 2.62 vs 3.05, P < 0.01, respectively). The sensitivity, specificity, positive predictive value, and negative predictive value for acute myocardial injury were as follows: 29%, 93%, 67%, and 73% for FSE-SPAIR; 38%, 91%, 67%, and 75% for FSE-STIR; 71%, 98%, 94%, and 88% for clinical interpretation including LGE, T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. CONCLUSIONS: Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

23 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: The availability of an accurate, noninvasive method using cardiac magnetic resonance imaging (MRI) to distinguish microscopic myocardial tissue changes at a macroscopic scale is well established. High-resolution in vivo monitoring of different pathologic tissue changes in the heart is a useful clinical tool for assessing the nature and extent of cardiac pathology. Cardiac MRI utilizes myocardial signal characteristics based on relaxation parameters such as T1, T2, and T2 star values. Identifying changes in relaxation time enables the detection of distinctive myocardial diseases such as cardiomyopathies and ischemic myocardial injury. The presented state-of-the-art review paper serves the purpose of introducing and summarizing MRI capability of tissue characterization in present clinical practice.
    Journal of thoracic imaging 01/2014; 29(6). DOI:10.1097/RTI.0000000000000053 · 1.74 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Purpose: To quantitatively investigate myocardial phase in multiple-gradient-echo images to determine normal phase angle ranges as a function of echo time and anatomical position and then compare phase values from patients with myocardial infarction with those normal ranges to determine the feasibility of intramyocardial hemorrhage detection. Methods: Fifteen normal control and 11 patients with reperfused myocardial infarction participated in this prospective study. A 1.5 T magnetic resonance system was used to perform volumetric CINE, high-pass filtered (HPF) phase, T2-weighted, T2*-weighted and late gadolinium-enhanced infarct imaging at four times points after myocardial infarction. HPF-phase analyzed using a 16-segment model was compared with late gadolinium-enhanced infarct imaging and T2* measurements. Results: Myocardial HPF-phase angle in the normal control group was small (-0.008 ± 0.027 radians). There was a difference between anatomical segments, with less variation in septal segments compared with cyclic variations in non-septal segments. Abnormal phase was only shown in myocardial segments with transmural late gadolinium-enhanced and microvascular obstruction consistent with intramyocardial hemorrhage. There were six studies from three patients (seven segments at 3 days, five segments at follow-up) with HPF-phase outside of normal range indicative of intramyocardial hemorrhage. Conclusion: Myocardial HPF-phase angle is normally small and varies by anatomical myocardial segment. intramyocardial hemorrhage causes a phase decrease beyond normal variations.
    Magnetic Resonance in Medicine 03/2014; 71(3). DOI:10.1002/mrm.24747 · 3.57 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Postmortem MRI (PMMR) examinations are seldom performed in legal medicine due to long examination times, unfamiliarity with the technique, and high costs. Furthermore, it is difficult to obtain access to an MRI device used for patients in clinical settings to image an entire human body. An alternative is available: ex situ organ examination. To our knowledge, there is no standardized protocol that includes ex situ organ preparation and scanning parameters for postmortem MRI. Thus, our objective was to develop a standard procedure for ex situ heart PMMR examinations. We also tested the oily contrast agent Angiofil® commonly used for PMCT angiography, for its applicability in MRI. We worked with a 3 Tesla MRI device and 32-channel head coils. Twelve porcine hearts were used to test different materials to find the best way to prepare and place organs in the device and to test scanning parameters. For coronary MR angiography, we tested different mixtures of Angiofil® and different injection materials. In a second step, 17 human hearts were examined to test the procedure and its applicability to human organs. We established two standardized protocols: one for preparation of the heart and another for scanning parameters based on experience in clinical practice. The established protocols enabled a standardized technical procedure with comparable radiological images, allowing for easy radiological reading. The performance of coronary MR angiography enabled detailed coronary assessment and revealed the utility of Angiofil® as a contrast agent for PMMR. Our simple, reproducible method for performing heart examinations ex situ yields high quality images and visualization of the coronary arteries.
    International Journal of Legal Medicine 08/2014; DOI:10.1007/s00414-014-1058-1 · 2.69 Impact Factor