Interface of an array of five capillaries with an array of one-nanoliter wells for high-resolution electrophoretic analysis as an approach to high-throughput chemical cytometry

Department of Chemistry, University of Washington, Seattle Washington 98195, USA.
Analytical Chemistry (Impact Factor: 5.83). 09/2008; 80(19):7631-4. DOI: 10.1021/ac800890b
Source: PubMed

ABSTRACT We report a system that allows the simultaneous aspiration of one or more cells into each of five capillaries for electrophoresis analysis. A glass wafer was etched to create an array of 1-nL wells. The glass was treated with poly(2-hydroxyethyl methacrylate) to control cell adherence. A suspension of formalin-fixed cells was placed on the surface, and cells were allowed to settle. The concentration of cells and the settling time were chosen so that there was, on average, one cell per well. Next, an array of five capillaries was placed so that the tip of each capillary was in contact with a single well. A pulse of vacuum was applied to the distal end of the capillaries to aspirate the content of each well into a capillary. Next, the tips of the capillaries were placed in running buffer and potential was applied. The cells lysed upon contact with the running buffer, and fluorescent components were detected at the distal end of the capillaries by laser-induced fluorescence. The electrophoretic separation efficiency was outstanding, generating over 750,000 theoretical plates (1,800,000 plates/m). In this example, AtT-20 cells were used that had been treated with TMR-G(M1). The cells were allowed to metabolize this substrate into a series of products before the cells were fixed. The number of cells found in each well was estimated visually under the microscope and was described by a Poisson distribution with mean of 0.98 cell/well. This system provides an approach to high-throughput chemical cytometry.

0 Followers
 · 
53 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Capillary electrophoresis (CE) is a promising technique for single-cell analysis, but its use in biological studies has been limited by low throughput. This paper presents an automated platform employing microfabricated cell traps and a three-channel system for rapid buffer exchange for fast single-cell CE. Cells loaded with fluorescein and Oregon green were analyzed at a throughput of 3.5 cells/min with a resolution of 2.3 ± 0.6 for the fluorescein and Oregon green. Cellular protein kinase B (PKB) activity, as measured by immunofluorescence staining of phospho-PKB, was not altered, suggesting that this stress-activated kinase was not upregulated during the CE experiments and that basal cell physiology was not perturbed prior to cell lysis. The activity of sphingosine kinase (SK), which is often upregulated in cancer, was measured in leukemic cells by loading a sphingosine-fluorescein substrate into cells. Sphingosine fluorescein (SF), sphingosine-1-phosphate fluorescein (S1PF), and a third fluorescent species were identified in single cells. A single-cell throughput of 2.1 cells/min was achieved for 219 total cells. 88% of cells possessed upregulated SK activity, although subpopulations of cells with markedly different SK activity relative to that of the population average were readily identified. This system was capable of stable and reproducible separations of biological compounds in hundreds of adherent and nonadherent cells, enabling measurements of previously uncharacterized biological phenomena.
    Analytical Chemistry 03/2013; 85(9). DOI:10.1021/ac4005887 · 5.83 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Cells are the organizing units of life. However, not all cells are alike; individual cells can differ significantly from their neighbors. These differences can be due to genetic, environmental, cell cycle, or stochastic effects, and these differences can have profound effects upon the behavior of a cellular population. A knowledge of the function and composition of individual cells will lead to deeper understanding of the response to disease, development, and environmental insult. Most biological techniques are incapable of determining cellular heterogeneity. Instead, most biological techniques begin with the homogenization of many millions of cells, and those techniques simply report the average composition and response of the population. These methods are inherently blind to the distribution of the cellular population. There is a simple reason why most biological measurements are performed on millions of cells. Cells are small, and very few biological techniques are capable of analyzing the minute amount of material contained within a cell. Consider a typical cell from a higher eukaryote. That cell might be 15 µ mi n diameter, corresponding to a volume of 1 pl and a mass of 1 ng. The cell is roughly 15% protein, corresponding to 150 pg; roughly 7% nucleic acids, corresponding to 70 pg; and roughly 2.5% carbohydrates and 2.5% lipids, corresponding to 25 pg. Analysis of this minute amount of material is a formidable challenge.
  • [Show abstract] [Hide abstract]
    ABSTRACT: A novel three-dimensional hydrodynamic focusing microfluidic device integrated with high-throughput cell sampling and detection of intracellular contents is presented. It has a pivotal role in maintaining the reducing environment in cells. Intracellular reducing species such as vitamin C and glutathione in normal and tumor cells were labeled by a newly synthesized 2,2,6,6-tetramethyl-piperidine-1-oxyl-based fluorescent probe. Hepatocytes are adherent cells, which are prone to attaching to the channel surface. To avoid the attachment of cells on the channel surface, a single channel microchip with three sheath-flow channels located on both sides of and below the sampling channel was developed. Hydrostatic pressure generated by emptying the sample waste reservoir was used as driving force of fluid on the microchip. Owing to the difference between the liquid levels of the reservoirs, the labeled cells were three-dimensional hydrodynamically focused and transported from the sample reservoir to the sample waste reservoir. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip without any external pressure pump, which drives three sheath-flow streams to constrain a sample flow stream into a narrow stream to avoid blockage of the sampling channel by adhered cells. The intracellular reducing levels of HepG2 cells and L02 cells were detected by home-built laser-induced fluorescence detector. The analysis throughput achieved in this microfluidic system was about 59-68 cells/min. Copyright © 2012 John Wiley & Sons, Ltd.
    Luminescence 02/2014; 29(1). DOI:10.1002/bio.2472 · 1.68 Impact Factor

Preview

Download
0 Downloads
Available from