Interface of an Array of Five Capillaries with an Array of One-Nanoliter Wells for High-Resolution Electrophoretic Analysis as an Approach to High-Throughput Chemical Cytometry

Department of Chemistry, University of Washington, Seattle Washington 98195, USA.
Analytical Chemistry (Impact Factor: 5.64). 09/2008; 80(19):7631-4. DOI: 10.1021/ac800890b
Source: PubMed


We report a system that allows the simultaneous aspiration of one or more cells into each of five capillaries for electrophoresis analysis. A glass wafer was etched to create an array of 1-nL wells. The glass was treated with poly(2-hydroxyethyl methacrylate) to control cell adherence. A suspension of formalin-fixed cells was placed on the surface, and cells were allowed to settle. The concentration of cells and the settling time were chosen so that there was, on average, one cell per well. Next, an array of five capillaries was placed so that the tip of each capillary was in contact with a single well. A pulse of vacuum was applied to the distal end of the capillaries to aspirate the content of each well into a capillary. Next, the tips of the capillaries were placed in running buffer and potential was applied. The cells lysed upon contact with the running buffer, and fluorescent components were detected at the distal end of the capillaries by laser-induced fluorescence. The electrophoretic separation efficiency was outstanding, generating over 750,000 theoretical plates (1,800,000 plates/m). In this example, AtT-20 cells were used that had been treated with TMR-G(M1). The cells were allowed to metabolize this substrate into a series of products before the cells were fixed. The number of cells found in each well was estimated visually under the microscope and was described by a Poisson distribution with mean of 0.98 cell/well. This system provides an approach to high-throughput chemical cytometry.

11 Reads
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: After chemoembolization of the liver with doxorubicin (Dox), this drug and its metabolites are not homogeneously distributed in this organ. The distribution cannot be easily measured making it difficult to assess how the drug performs in different tissue regions. Here we report a technique for sampling tissue cross sections that can analyze the contents of micrometer size regions. The tissue cross sections were from the explanted liver of a hepatocellular carcinoma patient. Samples were directly aspirated from a 5 microm thick tissue cross section into a 50 microm i.d. capillary where the tissue was solubilized with a separation buffer containing sodium dodecyl sulfate. Upon sample dissolution, Dox and natively fluorescent compounds were separated and detected by micellar electrokinetic chromatography with laser-induced fluorescence detection. Sampling reproducibility and recovery were assessed using 10% (w/v) gelatin as tissue mimic. Sampling from gelatin slices containing Dox revealed a relative standard deviation of 13%, which was comparable to that of sampling from solution. Dox recovery was 82% +/- 16% (n = 5). When sampling tumor and nontumor tissue regions, samples could be taken from the same region 100 microm apart. Atomic force microscopy was used to determine that each sample was 8.4 +/- 1.0 pL in volume which made it possible to determine Dox concentrations in the ranges of 0.4-1.3 and 0.3-0.5 microM for the samples taken from tumor and nontumor regions, respectively. The results demonstrated the feasibility of sampling, detection, and quantification of Dox in micrometer size regions, which could be a useful resource for analyzing the Dox concentration and distribution in highly heterogeneous tissues.
    Analytical Chemistry 04/2009; 81(9):3321-8. DOI:10.1021/ac802542e · 5.64 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A shotgun proteome analysis method and its performance for protein identification from 500 to 5000 cells are described. Sample preparation, which was done in one tube, involved the use of a surfactant (NP-40) for cell lysis, followed by acetone precipitation of the proteins. The resulting protein pellet was washed with cold acetone to remove remaining surfactant, and the pellet was then solubilized in NH(4)HCO(3). After trypsin digestion of the proteins, the digest was analyzed by the use of nanoflow liquid chromatography (LC) quadrupole time-of-flight mass spectrometry (QTOF MS). Sample injection and gradient speed in running LC QTOF MS were optimized. It was shown that this method could identify an average (n = 3) of 167 +/- 21, 237 +/- 30, 491 +/- 63, and 619 +/- 59 proteins from 500, 1000, 2500, and 5000 MCF-7 breast cancer cells, respectively. To demonstrate the potential use of this method for generating proteome profile from circulating tumor cells (CTCs) isolated from human blood, a healthy human blood sample was spiked with MCF-7 cells, and this mixture was processed and then subjected to antibody tagging of the MCF-7 cells. The tagged cells were sorted and collected using flow cytometry. The proteome profiles of small numbers of cells isolated in this way were found to be similar to those of the original MCF-7 cells, suggesting the possibility of the use of this method for cell typing of CTCs.
    Analytical Chemistry 03/2010; 82(6):2262-71. DOI:10.1021/ac9023022 · 5.64 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Cells are the organizing units of life. However, not all cells are alike; individual cells can differ significantly from their neighbors. These differences can be due to genetic, environmental, cell cycle, or stochastic effects, and these differences can have profound effects upon the behavior of a cellular population. A knowledge of the function and composition of individual cells will lead to deeper understanding of the response to disease, development, and environmental insult. Most biological techniques are incapable of determining cellular heterogeneity. Instead, most biological techniques begin with the homogenization of many millions of cells, and those techniques simply report the average composition and response of the population. These methods are inherently blind to the distribution of the cellular population. There is a simple reason why most biological measurements are performed on millions of cells. Cells are small, and very few biological techniques are capable of analyzing the minute amount of material contained within a cell. Consider a typical cell from a higher eukaryote. That cell might be 15 µ mi n diameter, corresponding to a volume of 1 pl and a mass of 1 ng. The cell is roughly 15% protein, corresponding to 150 pg; roughly 7% nucleic acids, corresponding to 70 pg; and roughly 2.5% carbohydrates and 2.5% lipids, corresponding to 25 pg. Analysis of this minute amount of material is a formidable challenge.
Show more


11 Reads
Available from