Article

D-dimer in preeclampsia: Systematic review and meta-analysis.

Department of Clinical and Toxicological Analysis, Faculty of Pharmacy, Universidade Federal de Minas Gerais, Brazil; School of Medicine, Universidade Federal de São João Del Rei, Brazil.
Clinica chimica acta; international journal of clinical chemistry (Impact Factor: 2.54). 08/2012; 414C:166-170. DOI: 10.1016/j.cca.2012.08.003
Source: PubMed

ABSTRACT Preeclampsia is a multifactorial disease characterized by high blood pressure and proteinuria after the 20th week of pregnancy. Preeclampsia is associated with microvasculature fibrin deposition and maternal organ dysfunction. D-dimer (D-Di) has been used as a marker of production/degradation of fibrin in vivo. D-Di has emerged as a useful diagnostic tool for thrombotic conditions because its plasma concentration has a high negative predictive value for venous thromboembolism. The aim of this study was to evaluate publications that assessed plasma D-Di in preeclampsia and normotensive pregnant subjects to define its diagnostic value. A total of 194 publications were identified. Following the exclusion process, seven studies were in accordance with the pre-defined eligibility criteria. This systematic review was performed with methodologic accuracy, including a careful definition of preeclampsia and a high sensitivity literature search strategy. Quality of the included studies was assessed in accordance with widely accepted literature recommendations. Our meta-analysis indicates that increased plasma D-Di is associated with preeclampsia in the third trimester of gestation vs normotensive pregnant subjects. These preliminary findings in this select group of patients clearly highlight the need for additional comprehensive studies throughout pregnancy, including the establishment of an appropriate cut-off, in order to fully elucidate the diagnostic/prognostic role of D-Di in preeclampsia.

1 Bookmark
 · 
297 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: A new method is described for identifying low concentrations of circulating derivatives of fibrinogen and fibrin, even when present in heterogeneous mixtures. This technique is applicable to plasma and serum and uses electrophoresis in 2% agarose in the presence of sodium dodecyl sulfate (SDS) followed by immunological identification of separated derivatives, using radiolabeled antifibrinogen antiserum and autoradiography. Unique electrophoretic patterns distinguish plasmic derivatives of crosslinked fibrin from those of fibrinogen and also identify crosslinked fibrin polymers produced by the combined action of thrombin and factor XIII on fibrinogen. The assay is sensitive to a concentration of 0.1 micrograms/mL of fibrinogen in serum or plasma. Fibrin polymers, plasmic degradation products of fibrinogen, and plasmic degradation products of crosslinked fibrin were detected in the plasma or serum of a patient with disseminated intravascular coagulation. Plasmic derivatives of both fibrinogen and crosslinked fibrin appeared in serum in the course of fibrinolytic therapy for pulmonary embolism, whereas during acute myocardial infarction a marked increase in the proportion of fibrin polymers in plasma was found in comparison with normal controls. Thus, the procedure can distinguish between the simultaneous processes of fibrin polymer formation, fibrinogenolysis, and fibrinolysis, and is sufficiently sensitive to detect relevant quantities of derivatives in pathologic conditions.
    Blood 04/1985; 65(3):589-97. · 9.78 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: There is growing evidence that fibrin D-dimer is associated with coronary and peripheral atherosclerosis. Using data from the Edinburgh Artery Study, we examined the distribution of fibrin D-dimer in 1592 men and women 55 to 74 years old and assessed its relationship with a range of cardiovascular risk factors. Fibrin D-dimer levels were higher in women than in men (P < or = .05) and increased with age (P < or = .001). Current cigarette smokers had higher levels than ex-smokers, who, in turn, had higher levels than those who had never smoked. On multiple regression analyses with age and plasma fibrinogen as covariates, only lifetime smoking in men and systolic blood pressure in women were independent predictors of fibrin D-dimer levels. Since fibrin D-dimer does not appear to be independently related to many of the common cardiovascular risk factors, it may be a useful index of the thrombotic contribution to arterial disease.
    Arteriosclerosis Thrombosis and Vascular Biology 09/1995; 15(8):1094-7. · 6.34 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The potential of plasma measurement of D-dimer (DD), a specific derivative of crosslinked fibrin, for diagnosis or exclusion of pulmonary embolism was investigated in a prospective series of 171 consecutive patients who attended an emergency department with suspected pulmonary embolism. The diagnosis was made or excluded by means of a clinical decision-making process which included clinical evaluation, ventilation-perfusion (VQ) lung scan, and, as indicated, pulmonary angiography, venography, or non-invasive examination of the leg veins. Pulmonary embolism was diagnosed by this process in 55 (32%) of 170 patients with sufficient data. All but 1 of these 55 patients had a DD concentration of 500 micrograms/l or above. The sensitivity and specificity of this cutoff concentration for the presence of pulmonary embolism were 98% and 39%, respectively, which give positive and negative predictive values of 44% and 98%. Among the 115 patients (68%) who had inconclusive VQ scans, 31 were diagnosed as having pulmonary embolism. 29 of the remaining 84 patients without pulmonary embolism had DD concentrations below 500 micrograms/l, which means that further diagnostic procedures could have been avoided in a quarter of the patients with inconclusive VQ scans. The sensitivity of the plasma measurement of DD remained high even 3 and 7 days after presentation (96% and 93%). Plasma measurement of DD therefore has a definite place in the diagnostic procedure for suspected acute pulmonary embolism in attenders at emergency departments: a concentration below 500 micrograms/l rules out the diagnosis.
    The Lancet 02/1991; 337(8735):196-200. · 39.21 Impact Factor

Full-text

Download
197 Downloads
Available from
Jun 4, 2014