Clinical equipoise: an argument for expedited approval of the first small step toward an autonomous artificial pancreas.

Yale Center for Clinical Investigation, Yale University School of Medicine, New Haven, CT, USA. .
Expert Review of Medical Devices (Impact Factor: 2.43). 07/2012; 9(4):315-7. DOI: 10.1586/erd.12.33
Source: PubMed
0 Bookmarks
 · 
55 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Strategies for preventing hypoglycemia during exercise in children with type 1 diabetes have not been well studied. The Diabetes Research in Children Network (DirecNet) Study Group conducted a study to determine whether stopping basal insulin could reduce the frequency of hypoglycemia occurring during exercise. Using a randomized crossover design, 49 children 8-17 years of age with type 1 diabetes on insulin pump therapy were studied during structured exercise sessions on 2 days. On day 1, basal insulin was stopped during exercise, and on day 2 it was continued. Each exercise session, performed from approximately 4:00-5:00 p.m., consisted of four 15-min treadmill cycles at a target heart rate of 140 bpm (interspersed with three 5-min rest breaks over 75 min), followed by a 45-min observation period. Frequently sampled glucose concentrations (measured in the DirecNet Central Laboratory) were measured before, during, and after the exercise. Hypoglycemia (< or = 70 mg/dl) during exercise occurred less frequently when the basal insulin was discontinued than when it was continued (16 vs. 43%; P = 0.003). Hyperglycemia (increase from baseline of > or = 20% to > or = 200 mg/dl) 45 min after the completion of exercise was more frequent without basal insulin (27 vs. 4%; P = 0.002). There were no cases of abnormal blood ketone levels. Discontinuing basal insulin during exercise is an effective strategy for reducing hypoglycemia in children with type 1 diabetes, but the risk of hyperglycemia is increased.
    Diabetes Care 10/2006; 29(10):2200-4. · 7.74 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Despite a high incidence of nocturnal hypoglycemia documented by the use of continuous glucose monitoring (CGM), there are no reports in the literature of nocturnal hypoglycemic seizures while a patient is wearing a CGM device. In this article, we describe four such cases and assess the duration of nocturnal hypoglycemia before the seizure. In the cases where patients had a nocturnal hypoglycemic seizure while wearing a CGM device, sensor hypoglycemia (<60 mg/dl) was documented on the CGM record for 2.25-4 h before seizure activity. Even with a subcutaneous glucose lag of 18 min when compared with blood glucose measurements, glucose sensors have time to provide clinically meaningful alarms. Current nocturnal hypoglycemic alarms need to be improved, however, since patients can sleep through the current alarm systems.
    Diabetes care 08/2008; 31(11):2110-2. · 7.74 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: It has been proposed that the first step towards a closed-loop artificial pancreas might be to use a continuous glucose sensor to automatically suspend the basal insulin delivery based on projected low sensor glucose values. We reviewed our recent experience with an artificial pancreas system, utilizing a proportional-integrative-derivative (PID) algorithm, in 17 adolescents with type 1 diabetes (T1D) to assess the safety and efficacy of this maneuver. During 34 h of closed-loop automated insulin delivery, 18 pump suspensions > or =60 min (90 +/- 18 min) occurred in eight subjects. Sensor glucose levels fell from 159 +/- 42 mg/dL to a nadir of 72 +/- 13 mg/dL. Corresponding plasma glucose levels fell from 168 +/- 51 to 72 +/- 16 mg/dL, with values <60 mg/dL recorded in only four of the 18 events. These data suggest that automatic pump suspension using the PID algorithm may be an effective means to prevent hypoglycemia in youth with T1D.
    Diabetes Technology &amp Therapeutics 04/2009; 11(4):207-10. · 2.21 Impact Factor