ABSTRACT To report surgical technique and clinical outcome of shoulder arthrodesis in dogs.
Multicenter clinical case series.
Dogs (n = 14).
Shoulder arthrodesis featured craniolateral plate and screw application, with application of a 2nd plate and screws craniolaterally or caudolaterally in 5 shoulders. Implants included the locking string of pearls (SOP)™ plate in 7 shoulders. Subjective preoperative, 5-8 weeks postoperative, and 11-16 weeks postoperative clinical and radiographic findings were documented. Owner questionnaire evaluation of outcome was performed 6-20 months postoperatively.
Mean angle of arthrodesis was 114° (range 102°-122°). Progression of arthrodesis was noted in 13/14 cases at both the 5-8 and 11-16 weeks postoperative radiographic assessments. Nine complications occurred in 7/14 dogs, graded as catastrophic in 2/9, major in 2/9, and minor in 5/9. Where morbidity was successfully managed, 11-16-week and 6-10-month postoperative limb function was positive on both veterinary and owner evaluations in almost all cases, and in several, functional lameness was considered sufficiently mild as to be imperceptible on subjective veterinary evaluation. Where present, limb circumduction was noted as the major feature of persistent lameness.
Shoulder arthrodesis in dogs results in acceptable limb function and should be considered for the management of debilitating shoulder pathology despite a high incidence of complications. Application of the SOP plate to aid shoulder arthrodesis warrants further study.

1 Follower
 · 
248 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Introduction: Partial resurfacing of the humeral head has been reported in humans to treat humeral osteochondritis dissecans. The aim is to describe a custom-made humeral resurfacing prosthesis for treatment of severe humeral head osteochondritis disse-cans in a dog. Case report: A seven-month-old female entire St. Bernard dog was presented with a 10 week history of severe left thoracic limb lameness. Radiography, arthroscopy and magnetic resonance imaging confirmed an extensive osteochondritis dissecans lesion affecting the caudal, medial and central regions of the humeral head. A prosthesis designed from computed tomography (CT) images was manufactured in polished stainless steel alloy with a hydroxyapatite coated base and central finned humeral stem for cementless insertion. A standard caudal approach to the shoulder was used to place the prosthesis following reaming of the caudal humeral head. Results: Radiography and CT imaging revealed appropriate topographical placement on the humerus. Force plate analysis demonstrated initial reduction in ground reaction force at six weeks, followed by gradual improvement at three months. There was no radiographic evidence of implant loosening and the range of shoulder joint motion was comparable to the contralateral joint at three months; these findings were maintained to final follow-up at 24 months. Clinical significance: Placement of a humeral head resurfacing prosthesis was an effective technique for the management of severe osteochondritis dissecans-related shoulder lameness. To the authors' knowledge, this is the first report of the clinical use of shoulder hemiarthroplasty in a dog.
    Veterinary and Comparative Orthopaedics and Traumatology 05/2014; 27(3):243-248. DOI:10.3415/VCOT-13-07-0087 · 1.03 Impact Factor