Article

Controlled delivery of bioactive molecules into live cells using the bacterial mechanosensitive channel MscL

HHMI, Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts 02115, USA.
Nature Communications (Impact Factor: 10.74). 08/2012; 3:990. DOI: 10.1038/ncomms1999
Source: PubMed

ABSTRACT Bacterial mechanosensitive channels are some of the largest pores in nature. In particular, MscL, with a pore diameter >25 Å, allows passage of large organic ions and small proteins. Functional MscL reconstitution into lipids has been proposed for applications in vesicular-based drug release. Here we show that these channels can be functionally expressed in mammalian cells to afford rapid controlled uptake of membrane-impermeable molecules. We first demonstrate that MscL gating in response to increased membrane tension is preserved in mammalian cell membranes. Molecular delivery is controlled by adopting an established method of MscL charge-induced activation. We then determine pore size limitations using fluorescently labelled model cargoes. Finally, we activate MscL to introduce the cell-impermeable bi-cyclic peptide phalloidin, a specific marker for actin filaments, into cells. We propose that MscL will be a useful tool for gated and controlled delivery of bioactive molecules into cells.

0 Followers
 · 
108 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The mechanosensitive channel of large conductance, MscL, has been proposed as a triggered nanovalve to be used in drug release and other nanodevices. It is a small homopentameric bacterial protein that has the largest gated pore known: greater than 30 Å. Large molecules, even small proteins can be released through MscL. Although MscL normally gates in response to membrane tension, early studies found that hydrophilic or charged residue substitutions near the constriction of the channel leads to pore opening. Researchers have successfully changed the modality of MscL to open to stimuli such as light by chemically modifying a single residue, G22, within the MscL pore. Here, by utilizing in vivo, liposome efflux, and patch clamp assays we compared modification of G22 with that of another neighboring residue, G26, and demonstrate that modifying G26 may be a better choice for triggered nanovalves used for triggered vesicular release of compounds.
    Biosensors & Bioelectronics 03/2013; 3(1):171-184. DOI:10.3390/bios3010171 · 6.45 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Significance: Sensations of touch and hearing are manifestations of mechanical contact and air pressure acting on touch receptors and hair cells of the inner ear, respectively. In bacteria, osmotic pressure exerts a significant mechanical force on their cellular membrane. Bacteria have evolved mechanosensitive (MS) channels to cope with excessive turgor pressure resulting from a hypo-osmotic shock. MS channel opening allows the expulsion of osmolytes and water, thereby restoring normal cellular turgor and preventing cell lysis. Recent Advances: As biological force-sensing systems MS channels have been identified as the best examples of membrane proteins coupling molecular dynamics to cellular mechanics. The bacterial MS channels of large (MscL) and small (MscS) conductance have been subjected to extensive biophysical, biochemical, genetic and structural analyses. These studies have established MscL and MscS as model systems for mechanosensory transduction. Critical Issues: In recent years, MS ion channels in mammalian cells have moved into focus of mechanotransduction research, accompanied by an increased awareness of the role they may play in the pathophysiology of diseases including cardiac hypertrophy, muscular dystrophy or Xerocytosis. Future Directions: A recent exciting development includes the molecular identification of Piezo proteins, which function as non-selective cation channels in mechanosensory transduction associated with senses of touch and pain. Since research on Piezo channels is very young, applying lessons learned from studies of bacterial MS channels to establishing the mechanism by which the Piezo channels are mechanically activated remains one of the future challenges towards better understanding of the role MS channels play in mechanobiology.
    Antioxidants & Redox Signaling 07/2013; DOI:10.1089/ars.2013.5471 · 7.67 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Cells can sense a myriad of mechanical stimuli. Mechanosensitive channel of large conductance (MscL) found in bacteria is a well-characterized mechanosensitive channel that rapidly responds to an increase in turgor pressure. Functional expression of MscL in mammalian cells has recently been demonstrated, revealing that molecular delivery or transport can be achieved by charge-induced activation of MscL. Despite a well-accepted mechanism for MscL activation by membrane tension in bacteria, it is not clear whether and how MscL can be opened by other modes of force transduction in mammalian cells. In this work, we used a variety of techniques to characterize the gating of MscL expressed in mammalian cells, using both wild type and a G22S mutant which activates at a lower threshold. In particular, employing a recently developed technique, acoustic tweezing cytometry (ATC), we show that ultrasound actuation of integrin-bound microbubbles can lead to MscL opening and that ATC induced MscL activation was dependent on the functional linkage of the microbubbles with an intact actin cytoskeleton. Our results indicate that localized mechanical stress can mediate opening of MscL that requires force transduction through the actin cytoskeleton, revealing a new mode of MscL activation that may prove to be a useful tool for mechanobiology and drug delivery research.
    Cellular and Molecular Bioengineering 06/2014; 7(3). DOI:10.1007/s12195-014-0337-8 · 1.23 Impact Factor

Preview

Download
0 Downloads
Available from