Article

Vector transmission matrix for the polarization behavior of light propagation in highly scattering media.

Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406, W. Green St., Urbana, Illinois 61801, USA.
Optics Express (Impact Factor: 3.53). 07/2012; 20(14):16067-76. DOI: 10.1364/OE.20.016067
Source: PubMed

ABSTRACT Recently the optical transmission matrix (TM) has been shown to be useful in controlling the propagation of light in highly scattering media. In this paper, we present the vector transmission matrix (VTM) which, unlike the TM, captures both the intensity and polarization transmission property of the scattering medium. We present an experimental technique for measuring the absolute values of the VTM elements which is in contrast to existing techniques whereby the TM elements are measured to within a scaling factor. The usefulness of the VTM is illustrated by showing that it can be used to both predict and control the magnitude of the complex polarization ratio of the light focused through the scattering medium. To the best of our knowledge, this is the first study to show the possibility of controlling the polarization of the light transmitted through highly scattering media.

0 Bookmarks
 · 
64 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Transcranial focused ultrasound is a promising therapeutic modality. It consists of placing transducers around the skull and emitting shaped ultrasound waves that propagate through the skull and then concentrate on one particular location within the brain. However, the skull bone is known to distort the ultrasound beam. In order to compensate for such distortions, a number of techniques have been proposed recently, for instance using Magnetic Resonance Imaging feedback. In order to fully determine the focusing distortion due to the skull, such methods usually require as many calibration signals as transducers, resulting in a lengthy calibration process. In this paper, we investigate how the number of calibration sequences can be significantly reduced, based on random measurements and optimization techniques. Experimental data with six human skulls demonstrate that the number of measurements can be up to three times lower than with the standard methods, while restoring 90% of the focusing efficiency.
    Physics in Medicine and Biology 02/2015; 60(3):1069-85. DOI:10.1088/0031-9155/60/3/1069 · 2.92 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: We demonstrate feasibility of a an spatially-modulated multi-photon microscopy (S-MPM) technique that can image through complex media that strongly scatters light, and we describe performance achieved with a prototype instrument. S-MPM’s imaging advantages are enabled by a high-speed, microelectromechanical spatial light modulator (MEMS SLM) subsystem with 1020 independently controllable mirror segments.
    SPIE Defense + Security; 06/2014
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: We report the measurement of a large optical reflection matrix (RM) of a highly disordered medium. Incident optical fields onto a turbid sample are controlled by a spatial light modulator, and the corresponding fields reflected from the sample are measured using full-field Michelson interferometry. The number of modes in the measured RM is set to exceed the number of resolvable modes in the scattering media. We successfully study the subtle intrinsic correlations in the RM which agrees with the theoretical prediction by random-matrix theory when the effect of the limited numerical aperture on the eigenvalue distribution of the RM is taken into account. The possibility of the enhanced delivery of incident energy into scattering media is also examined from the eigenvalue distribution which promises efficient light therapeutic applications.

Full-text (2 Sources)

Download
6 Downloads
Available from
Sep 25, 2014