Article
Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.
Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil.
The journal of advanced prosthodontics
05/2012;
4(2):89-92.
DOI:10.4047/jap.2012.4.2.89
pp.89-92
Source: PubMed
- Citations (25)
-
Cited In (0)
-
Article: The significance of passive framework fit in implant prosthodontics: current status.
[show abstract] [hide abstract]
ABSTRACT: The clinical and laboratory procedures employed for framework fabrication are inadequate to provide an absolute passive fit for implant-supported fixed superstructures. Although some prosthetic complications are attributed to the lack of passive fit, its effect on implant success is questionable. Nevertheless, the clinical results of increasing applications of advanced technology to improve framework fit seem promising. This article reviews the clinical significance of passive fit and the factors that affect the final fit of implant-supported frameworks.Implant Dentistry 02/2001; 10(2):85-92. · 1.05 Impact Factor -
Article: Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems.
[show abstract] [hide abstract]
ABSTRACT: Besides load-bearing capacity, marginal accuracy is a further crucial factor influencing the clinical long-term reliability of fixed dental prostheses (FDPs). The aim of this in vitro study was to evaluate the marginal fit of four-unit zirconia bridge frameworks fabricated using four different computer-aided design (CAD)/computer-aided manufacturing (CAM) systems. Ten frameworks were manufactured using each fabricating system. Three systems (inLab, Everest, Cercon) processed white-stage zirconia blanks, which had to be sintered to final density after milling, while with one system (Digident) restorations were directly milled from a fully sintered material. After manufacturing, horizontal and vertical marginal discrepancies, as well as the absolute marginal discrepancy, were determined by means of a replica technique. The absolute marginal discrepancy, which is considered to be the most suitable parameter reflecting restorations' misfit in the marginal area, had a mean value of 58 mum for the Digident system. By contrast, mean absolute marginal discrepancies for the three other systems, processing presintered blanks, differed significantly and ranged between 183 and 206 mum. Within the limitations of this study, it could be concluded that the marginal fit of zirconia FDPs is significantly dependent on the CAD/CAM system used, with restorations processed of fully sintered zirconia showing better fitting accuracy.European Journal Of Oral Sciences 07/2009; 117(3):319-25. · 1.88 Impact Factor -
Article: Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup.
[show abstract] [hide abstract]
ABSTRACT: A total of 391 edentulous maxillae and mandibles was consecutively treated with routine fixed prostheses, supported by 2,199 implants. The patients were followed for 1 year; the overall success rate was 99.5% and 98.1% for the prostheses and implants, respectively. The number of severe complications was low, but it was possible to identify a significantly higher ratio of problems in the maxillae throughout the observation period than for the mandibles. While many problems occurred in both the maxillae and mandibles, there were also problems more typical for each jaw. Diction and fractures of resin teeth were more common problems in maxillae; cheek and lip biting was a more frequent postinsertion complication in the treatment of mandibles. Most problems were easily resolved, and the retrievability of the prostheses was of great advantage.The International journal of oral & maxillofacial implants 02/1991; 6(3):270-6. · 1.78 Impact Factor
Data provided are for informational purposes only. Although carefully collected, accuracy cannot be guaranteed.
The impact factor represents a rough estimation of the journal's impact factor and does not reflect the actual
current impact factor.
Publisher conditions are provided by RoMEO. Differing provisions from the publisher's actual policy or licence
agreement may be applicable.
Keywords
3-element implant-supported frameworks
Adequate passive-fitting
alternative method
Casting diagonally sectioned frameworks
diagonal axis
diagonal section
diagonally
diagonally sectioning one-piece frameworks
Group B
Group C
implant-supported frameworks
laser welding
Lower misfit levels
misfit levels
one-piece
one-piece castings
short communication
Three-unit implant-supported nickel-chromium
transversally sectioned
vertical misfit