Impact of chorioamnionitis on exhaled nitric oxide and endotracheal aspirate levels of nitrites–nitrates and interleukin‐8 in mechanically ventilated preterm neonates

Pediatric Pulmonology (Impact Factor: 2.38). 05/2011; 46(6):595 - 603. DOI: 10.1002/ppul.21410

ABSTRACT Objectives
To assess the influence of maternal chorioamnionitis on early exhaled nitric oxide (NO) and levels of nitrites–nitrates and interleukin (IL)-8 in endotracheal aspirate fluid in mechanically ventilated preterm neonates.Study DesignCross-sectional study.Patient–Subject SelectionBetween September 2007 and August 2009, 54 mechanically ventilated preterm neonates were included. Patients were divided into two groups according to the presence or absence of maternal chorioamnionitis, and those without chorioamnionitis (controls) were further stratified into two subgroups by birth weight < or ≥2,000 g.MethodologyThe ventilator used was a Babylog 8000. The NO level assessed was the plateau value given by the software of the Sievers NOA apparatus. Collection of endotracheal aspirate fluid samples was performed coinciding with routine aspirations and using the dry technique.ResultsThe two groups of control neonates showed statistically significant differences in exhaled NO expressed as nl/min and normalized exhaled NO expressed as either nl/min or nl/min/kg, so they are not homogeneous and cannot be used in clinical practice. Serum C-reactive protein and endotracheal aspirate levels of nitrites–nitrates were significantly higher in the chorioamnionitis group than in controls (3.6 vs. 1.07 µmol/L; P = 0.035). Nitrites–nitrates levels were positively correlated with exhaled NO in ppb (ρ = 0.367; P = 0.006). Minute exhaled endogenous NO was significantly higher in the chorioamnionitis group (0.48 vs. 0.27 nl/min/kg; P = 0.021).Conclusions
In mechanically ventilated preterm infants weighing <2,000 g, maternal chorioamnionitis was associated with an increase of early exhaled NO (nl/min/kg) and serum levels of C-reactive protein and levels of nitrites–nitrates in endotracheal aspirate fluid. Pediatr. Pulmonol. 2011; 46:595–603. © 2011 Wiley-Liss, Inc.

1 Bookmark
 · 
61 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Despite widespread use of drugs to arrest preterm labor, there has been no decrease in the numbers of low-birth-weight or preterm infants in the last 20 years. Evidence from many sources links preterm birth to symptomatic and subclinical infections. Recently, an increasing body of evidence has suggested that not only is subclinical infection responsible for preterm birth but also for many serious neonatal sequelae, including periventricular leukomalacia, cerebral palsy, respiratory distress and even bronchopulmonary dysplasia and necrotizing enterocolitis. Proxies of intrauterine infection include clinical chorioamnionitis, histological chorioamnionitis and intraamniotic increase in cytokines, which have been found to be associated with acute neonatal morbidity and mortality and, at least to some degree, with neurological impairment, chronic lung disease and thymus involution in the preterm infant. The infectious/inflammatory mechanisms involved are not fully understood, and the types of microbes and genetic features of host adaptive and innate immune responses need to be better characterized.
    Biology of the Neonate 02/2003; 83(2):85-96. · 1.90 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Chronic lung disease is a common adverse outcome of prematurely born infants and is associated with an early inflammatory response, which persists over weeks. As a consequence, it is possible that exhaled nitric oxide levels might be raised in affected infants. The majority of such infants will be ventilated in the first weeks of birth and thus it is important to determine the influence of mechanical ventilation on nitric oxide levels. As a consequence, our aim was to determine whether, during mechanical ventilation, simulated exhaled nitric oxide levels were influenced by changes in ventilator settings or the sampling catheter position. A lung model was created consisting of a rubber bag inside a 11 jar. An endotracheal tube (ETT) was fixed securely within the neck of the bag. Nitric oxide was delivered into the bag at a constant rate to simulate production and sampled from within the ETT and the bag. The sampled nitric oxide was analysed using a Sievers chemiluminescence analyser. The ETT was attached to a neonatal ventilator and a nitric oxide scavenger placed in the ventilator's inspiratory limb to ensure nitric oxide free gas was delivered. Comparison of different sampling positions revealed that the highest peak nitric oxide level within the ETT was at the tip. Increasing peak inflating pressure and ventilator rate resulted in a decrease in the peak nitric oxide levels. Increasing the inspired oxygen concentration also was associated with a reduction in the peak nitric oxide levels, the effect being more pronounced when larger volume lung models were examined. The results emphasized that the conditions of measurement must be standardized in infants receiving respiratory support, if exhaled nitric oxide results are to be appropriately interpreted.
    Physiological Measurement 03/2003; 24(1):1-9. · 1.50 Impact Factor
  • Acta Paediatrica 05/1999; 88(4):471-2. · 1.97 Impact Factor

Full-text (2 Sources)

View
15 Downloads
Available from
Jun 1, 2014