The use of Hemastix® and the subsequent lack of DNA recovery using the Promega DNA IQTM system

Journal of Forensic Sciences (Impact Factor: 1.16). 10/2009; 54(6):1278 - 1286. DOI: 10.1111/j.1556-4029.2009.01173.x


  Following implementation of our automated process incorporating the Promega DNA IQTM system as a DNA extraction method, a large number of blood-containing exhibits failed to produce DNA. These exhibits had been tested with the Hemastix® reagent strip, commonly used by police investigators and forensic laboratories as a screening test for blood. Some exhibits were even tainted green following transfer of the presumptive test reagents onto the samples. A series of experiments were carried out to examine the effect of the Hemastix® chemistries on the DNA IQTM system. Our results indicate that one or more chemicals imbedded in the Hemastix® reagent strip severely reduce the ability to recover DNA from any suspected stain using the DNA IQTM magnetic bead technology. The 3,3′,5,5′-tetramethylbenzidine (TMB) used as the reporting dye appears to interact with the magnetic beads to prevent DNA recovery. Hydrogen peroxide does not seem to be involved. The Hemastix® chemistries do not interfere in any way with DNA extraction performed using phenol-chloroform. The incompatibility of the Hemastix® chemistries on the DNA IQTM system forced us to adopt an indirect approach using filter paper to carry out the presumptive test.

166 Reads
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Despite the limited power available in a battery- operated hand-held device, a display system must still have an enough resolution and sufficient color depth to deliver the neces- sary information. We introduce some methodologies for frame buffer compression that efficiently reduce the power consump- tion of display systems and thus distinctly extend battery life for hand-held applications. Our algorithm is based on a run-length encoding for on-the-fly compression, with a negligible burden in resources and time. We present an adaptive and incremental re-compression technique to maintain efficiency under frequent partial frame buffer updates. We save about 30% to 90% frame buffer activity on average for various hand-held applications. We have implemented an LCD controller with frame buffer compression occupying 1,026 slices and 960 flip-flops in a Xilinx Sprantan-I1 FPGA, which has an equivalent gate count of 65,000 gates. It consumes 30mW more power and 10% additional silicon space than an LCD controller without frame buffer compression, but reduces the power consumption of the frame buffer memory by 400mW.
    Proceedings of the 2004 Conference on Asia South Pacific Design Automation: Electronic Design and Solution Fair 2004, Yokohama, Japan, January 27-30, 2004; 01/2004
  • [Show abstract] [Hide abstract]
    ABSTRACT: The choice of reagents for presumptive tests for blood, and subsequent extraction methodologies, can significantly affect both the quantity and quality of purified DNA. Blood samples directly tested with Hemastix(®) yielded <1% of the DNA recovered from untested samples when purified using the Qiagen BioRobot(®) EZ1 and EZ1(®) DNA Investigator kit. Full short tandem repeat profiles were obtained from both tested and untested samples, suggesting that the Hemastix(®) reagent(s) affect DNA binding, rather than produce DNA damage. The Hemastix(®) inhibition of DNA yield could be overcome by the addition of MTL buffer to the sample prior to extraction. Laboratories may wish to modify current procedures for extracting blood samples, utilize other extraction/purification methodologies, or inform their submitting agencies to avoid direct exposure of questioned bloodstains to Hemastix(®) reagents.
    Journal of Forensic Sciences 03/2011; 56(3):733-5. DOI:10.1111/j.1556-4029.2011.01737.x · 1.16 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: With advancements in technology allowing for the miniaturization of consumer electronics, criminal investigations of all types frequently involve the forensic examination of electronic devices, such as cellular telephones, smartphones, and portable flash memory; in some extreme, violent cases, these devices are found covered in blood. Due to the complexity of such devices, standard operating procedures for the complete removal of blood had not previously been established by the Royal Canadian Mounted Police prior to this study. The electronics industry has adopted the use of the ultrasonic cleaner for sanitizing printed circuit boards (PCBs) by removing residues and contaminants. High frequency sound waves created by the machine penetrate and remove dirt and residues; however, early research during the 1950s recorded these sound waves breaking the internal bonds of integrated circuit chips. Experimentation with modern ultrasonic technology was used to determine if internal components were damaged, as well as if ultrasonic cleaning was the most suitable method for the removal of dried and liquid blood from a PCB. Several disinfectant solutions were compared against the 0.5% Triton(®) X-100 detergent solution in the ultrasonic cleaner, including: 10% sodium hypochlorite bleach, 85% isopropyl alcohol, and Conflikt(®) disinfectant spray. The results not only demonstrated that the ultrasonic cleaner did not damage the vital memory chip on the PCB, but also, with the assistance of Conflikt(®), was able to remove all traces of blood as indicated by Hemastix(®) reagent strips. Of five methods experimented with, two cycles of ultrasonic cleaning followed by sanitization with Conflikt(®) proved to be the only procedure capable of removing all traces of blood, as confirmed with both Hemastix(®) reagent strips and the hemochromogen test.
    Forensic science international 08/2011; 214(1-3):88-95. DOI:10.1016/j.forsciint.2011.07.022 · 2.14 Impact Factor
Show more

Preview (4 Sources)

166 Reads
Available from