Article

The Leuven isotope separator on-line laser ion source

Instituut voor Kern- en Stralingsfysica, University of Leuven, Celestijnenlaan 200 D, B-3001 Leuven, Belgium
Nuclear Physics A (Impact Factor: 1.53). 04/2002; 701(1-4):465c. DOI: 10.1063/1.1146778

ABSTRACT An element-selective laser ion source has been used to produce beams of exotic radioactive nuclei
and to study their decay properties. The operational principle of the ion source is based on selective
resonant laser ionization of nuclear reaction products thermalized and neutralized in a noble gas at
high pressure. The ion source has been installed at the Leuven Isotope Separator On-Line (LISOL),
which is coupled on-line to the cyclotron accelerator at Louvain-la-Neuve. 54,55Ni and 54,55Co
isotopes were produced in light-ion-induced fusion reactions. Exotic nickel, cobalt and copper nuclei
were produced in proton-induced fission of 238U. The b decay of the 68–74Ni, 67–70Co, 70–75Cu and
110–114Rh isotopes has been studied by means of β–γ and γ –γ spectroscopy. Recently, the laser ion
source has been used to produce neutron-deficient rhodium and ruthenium isotopes (91–95Rh, 98Rh,
90,91Ru) near the N = Z line in heavy ion-induced fusion reactions.

0 Bookmarks
 · 
94 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Gas jets emitted from an ion guide have been studied as a function of nozzle type and gas cell-to-background pressure ratio in order to obtain a low divergent, uniform jet over a distance of several cm. The jet has been probed by imaging the light emitted from excited argon or helium gas atoms. For a simple exit hole or converging-diverging nozzle, the jet diameter was found to be insensitive to the nozzle shape and inlet pressure. Sonic jets with a FWHM below 6 mm were achieved with a background pressure larger than 1 mbar in the expansion chamber. The measurements are supported by the detection of radioactive 219Rn recoils from an alpha recoil source mounted within the gas cell. A Laval nozzle produced a well-collimated supersonic jet at low background pressures with a FWHM of over a distance of 14 cm. Direct Pitot probe measurements, on-axis, revealed a non-uniform pressure distribution in the gas jet of the Laval nozzle, supporting the visual observations. All measurements are motivated by the requirement of a good geometrical overlap between atoms and counter-propagating laser beams in the gas cell-based Laser Ion Source Trap (LIST) project. Computational fluid dynamics gas flow simulations were initiated to guide the future development of the gas jet system.
    Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 01/2011; · 1.14 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Resonant ionisation laser ion sources are nowadays extensively used, when available, at many leading on-line facilities. Moreover, new laser ion sources are now under development in most of the recent on-line facility projects under construction worldwide. This success is mainly due to the reliability, the ionization efficiency and the high purity that this type of source can achieve for the production of radioactive species and for a large range of chemical elements. Laser ion sources for radioactive beams gather many different systems such as dye laser or all-solid state titanium:sapphire laser systems, high or low repetition rates, hot cavities or gas cells, additional selectivity by using chemical techniques, or the LIST technique (laser ion source trap). In this paper, the physics of laser ion sources will be described with the current limitations and challenges for the future. An overview of the laser ion source facilities will be given, with an emphasis on the ongoing developments and perspectives on LIS.
    The Review of scientific instruments 02/2012; 83(2):02A916. · 1.52 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The Resonant Ionization Laser Ion Source (RILIS) is an element selective, highly efficient and versatile tool for generation of radioactive ion beams at on-line mass separator facilities. Parallel to TRIUMF’s on-line RILIS at the Isotope Separator and ACcelerator (ISAC) facility, an off-line Laser Ion Source test stand (LIS STAND) is operated for systematic laser resonance ionization spectroscopy, ionization scheme and ion source development. Three titanium sapphire (Ti:Sa) lasers optionally equipped with harmonic frequency generation units are used to resonantly step-wise excite and ionize elements of interest. A grating tuned Ti:Sa laser allows continuous laser wavelength scans of up to Δ≈200nm. With this laser inventory and the LIS STAND, atomic Rydberg series and auto-ionizing levels can systematically be studied. The LIS STAND has been in use since 2009 and so far the spectroscopy on Ga, Al and Ca has been performed. The development of efficient laser resonant ionization schemes, their investigation and comparison using the LIS STAND are discussed.
    Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms 08/2013; 308:74–79. · 1.27 Impact Factor

Full-text (3 Sources)

View
128 Downloads
Available from
May 21, 2014