Article

Fabrication of a novel holmium(III) PVC membrane sensor based on 4-chloro-1,2-bis(2-pyridinecarboxamido)benzene as a neutral ionophore

Center of Excellence in Electrochemistry, University of Tehran, Tehran, Iran; Endocrine & Metabolism Research Center of Medical Sciences, University of Tehran, Tehran, Iran
Journal of Applied Electrochemistry (Impact Factor: 1.84). 01/2007; 37(7):853-859. DOI: 10.1007/s10800-007-9321-5

ABSTRACT This paper introduces the development of an original PVC membrane electrode, based on 4-chloro-1,2-bis(2-pyridinecarboxamido)benzene
(CBPB) as a suitable carrier for the Ho3+ ion. The electrode presents a Nernstian slope of 19.7±0.3mV per decade for the Ho3+ ions across a broad working concentration range from 1.0×10−6 to 1.0×10−2M. The lower detection limit was 8.5×10−7M in the pH range 2.7–9.8, while the response time was rapid (<15s). Therefore, this potentiometric sensor displayed good
selectivity for a number of cations such as alkali, alkaline earth, transition and heavy metal ions. The practical applicability
of the electrode was demonstrated by its use as an indicator electrode in the potentiometric titration of Ho3+ ions with EDTA and in the determination of F- in mouth wash samples.

0 Bookmarks
 · 
75 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: The need for the prompt lutetium determination becomes urgent when considering that the risk of its penetration into humans, animals, and plants results in the alteration of the physiological processes of their cells. Subsequently, it is of great importance to develop an efficient method for the accurate lutetium determination. This study demonstrates the development of a N,N'-bis(2-pyridinecarboxamide)-1,3-benzene (BPMB)-Lu(III) potentiometric membrane sensor, illustrating the best overall performance in comparison with the other respective sensors in the literature. In detail, the sensor displayed a lower detection limit of 6.3 × 10-7 M, a Nernstian response in the range of 1.0 × 10-6 M-1.0 × 10-1 M and a prompt response time (∼5 sec). Its reproducibility was satisfactory with a relatively good discriminating ability for the lutetium(III) ions among many common cations and lanthanide ions. For the pH values of 3.0-7.5, the sensor potential response remained constant despite the pH fluctuations. This electrode performance was accomplished with a membrane composition of 30% PVC, 63% benzyl acetate (BA), 5% BPMB, and 2% sodium tetraphenylborate (NaTPB). In parallel, the sensor was evaluated by determining the lutetium ion concentration at a Certified Reference Material (CRM), named the Coal and Fuel Ash analysis (FFA 1 Fly Ash), synthetic human serum, and some soil and sediment samples. Copyright © Taylor & Francis Group, LLC.
    Analytical Letters 01/2008; 41(1):3-23. · 0.97 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The increase use of ion sensors in the fields of environmental, agricultural, and medical analysis is stimulating analytical chemists to develop new sensors for fast, accurate, reproducible, and selective determination of various ions. In this study a new samarium membrane sensor was constructed and for the first time, it was applied as a probe in indirect determination of hyoscine, homatropine, and tramadol drugs in their pharmaceutical formulation. The proposed membrane sensor was constructed based on a membrane containing 2% sodium tetraphenyl borate (NaTPB) as an anionic additive, 63% dibutyl phthalate (DBP) as solvent mediator, 5% ionophore, and 30% poly(vinyl chloride) (PVC). The proposed Sm(III) electrode exhibits a Nernstian response of 19.35±0.2 mV per decade of samarium concentration, and has a lower detection limit of 1.0×10−7 M. The linear range of the sensors was 1.0×10−7–1.0×10−1 M. It works well in the pH range of 3.0–8.0.
    Electroanalysis 11/2008; 20(24):2663 - 2670. · 2.82 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Many research studies have been conducted on the use of conjugated polymers in the construction of chemical sensors including potentiometric, conductometric and amperometric sensors or biosensors over the last decade. The induction of conductivity on conjugated polymers by treating them with suitable oxidizing agents won Heeger, MacDiarmid and Shirakawa the 2000 Nobel Prize in Chemistry. Common conjugated polymers are poly(acetylene)s, poly(pyrrole)s, poly(thiophene)s, poly(terthiophene)s, poly(aniline)s, poly(fluorine)s, poly(3-alkylthiophene)s, polytetrathiafulvalenes, polynapthalenes, poly(p-phenylene sulfide), poly(p-phenylenevinylene)s, poly(3,4-ethylenedioxythiophene), polyparaphenylene, polyazulene, polyparaphenylene sulfide, polycarbazole and polydiaminonaphthalene. More than 60 sensors for inorganic cations and anions with different characteristics based on conducting polymers have been reported. There have also been reports on the application of non-conducting polymers (nCPs), i.e. PVC, in the construction of potentiometric membrane sensors for determination of more than 60 inorganic cations and anions. However, the leakage of ionophores from the membranes based on these polymers leads to relatively lower life times. In this article, we try to give an overview of Solid-Contact ISE (SCISE), Single-Piece ISE (SPISE), Conducting Polymer (CP)-Based, and also non-conducting polymer PVC-based ISEs for various ions which their difference is in the way of the polymer used with selective membrane. In SCISEs and SPISEs, the plasticized PVC containing the ionophore and ionic additives govern the selectivity behavior of the electrode and the conducting polymer is responsible of ion-to-electron transducer. However, in CPISEs, the conducting polymer layer is doped with a suitable ionophore which enhances the ion selectivity of the CP while its redox response has to be suppressed.
    Sensors. 01/2008;