PROSE treatment of corneal ectasia

Boston Foundation for Sight, Needham, MA, United States.
Contact lens & anterior eye: the journal of the British Contact Lens Association (Impact Factor: 1.37). 05/2012; 35(5):222-7. DOI: 10.1016/j.clae.2012.04.003
Source: PubMed


Prosthetic replacement of the ocular surface ecosystem (PROSE) uses custom designed and fabricated prosthetic devices in a treatment that restores vision, supports healing, reduces symptoms and improves quality of life in patients with complex corneal disease. We report the success rate for PROSE treatment of corneal ectasia.
Records of 59 patients with corneal ectasia seen in consultation over 6months were reviewed. Candidacy for treatment, topographic indices, change in visual acuity, achievement of satisfactory fit, device wear status and change in visual function at 6months were recorded.
Sixteen eyes were non-candidates because conventional correction was adequate. Trial devices were inserted but not dispensed for 13 eyes. No eyes were excluded for severity of ectasia. In the remaining 89 eyes, satisfactory fit was achieved and a device was dispensed. Twenty-one eyes (15 patients) had undergone penetrating keratoplasty. Device wear at 6months was documented in 78/89 eyes (88%). NEI VFQ-25 score improved 27.6 points (p<0.001) on a 100 point scale in patients wearing a device at 6months.
All candidate eyes with corneal ectasia could be fitted with a PROSE device. PROSE treatment has a high success rate when measured by ability to achieve satisfactory fit, impact on visual acuity and 6month data on both rate of continued wear and impact on visual function. PROSE treatment is an alternative to penetrating keratoplasty for patients with corneal ectasia who are contact lens intolerant.

Download full-text


Available from: Fateme Alipour,
127 Reads
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Purpose. To assess optical coherence tomography (OCT) for guiding design and fit of a prosthetic device for corneal disease. Methods. A prototype time domain OCT scanner was used to image the anterior segment of patients fitted with large diameter (18.5-20 mm) prosthetic devices for corneal disease. OCT images were processed and analyzed to characterize corneal diameter, corneal sagittal height, scleral sagittal height, scleral toricity, and alignment of device. Within-subject variance of OCT-measured parameters was evaluated. OCT-measured parameters were compared with device parameters for each eye fitted. OCT image correspondence with ocular alignment and clinical fit was assessed. Results. Six eyes in 5 patients were studied. OCT measurement of corneal diameter (coefficient of variation, CV = 0.76%), cornea sagittal height (CV = 2.06%), and scleral sagittal height (CV = 3.39%) is highly repeatable within each subject. OCT image-derived measurements reveal strong correlation between corneal sagittal height and device corneal height (r = 0.975) and modest correlation between scleral and on-eye device toricity (r = 0.581). Qualitative assessment of a fitted device on OCT montages reveals correspondence with slit lamp images and clinical assessment of fit. Conclusions. OCT imaging of the anterior segment is suitable for custom design and fit of large diameter (18.5-20 mm) prosthetic devices used in the treatment of corneal disease.
    Journal of Ophthalmology 12/2012; 2012:812034. DOI:10.1155/2012/812034 · 1.43 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: To study the effect of optic asphericity on visual rehabilitation of corneal ectasia with a prosthetic device. Subjects with corneal ectasia treated with a fluid-ventilated gas-permeable prosthetic device of diameter 18.0-19.0 mm, who had subjective improvement of good Snellen vision with introduction of optic asphericity, were studied. Best corrected Snellen visual acuity (BCVA) under standard illumination, high contrast visual acuity (HCVA), low contrast visual acuity (LCVA), and wavefront aberrations were measured in a sequence of devices that varied per patient only in presence or amount of ellipsoidal front surface optical eccentricity (FSE). Five eyes of 5 subjects were studied. (M:F = 3:2; Age: 20-76). Mean steepest SimK was 57.72±8.30 D. BCVA was ≥20/30 in all eyes in all prosthetic devices, regardless of FSE. Although FSE improved BCVA, HCVA, and LCVA in each patient, no optimal amount could be identified in this small series. Asphericity in the form of 0.6 or 0.8 FSE improved HCVA, LCVA, or both in each patient. FSE was associated with a trend toward reduction of higher-order aberrations, particularly coma. Optic asphericity shows promise for optimization of vision in the rehabilitation of corneal ectasia with a prosthetic device.
    Eye & contact lens 09/2012; 38(5):300-5. DOI:10.1097/ICL.0b013e3182657da5 · 1.47 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: We used a unique combination of four state-of-the-art technologies to achieve a high performance spectral domain optical coherence tomography system suitable for imaging the entire ocular surface. An ultra-high resolution, extended depth range, full-phase interferometry, and high-speed complementary metal-oxide semiconductor transistor camera detection provided unprecedented performance for the precise quantification of a wide range of the ocular surface. We demonstrated the feasibility of this approach by obtaining high-speed and high-resolution images of a model eye beyond the corneal-scleral junction. Surfaces determined from the images with a segmentation algorithm demonstrated excellent accuracy and precision.
    Clinical ophthalmology (Auckland, N.Z.) 08/2013; 7:1623-33. DOI:10.2147/OPTH.S45122