Article

Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty.

Orthopaedic Unit and "Kirk Kilgour" Sports Injury Centre, S. Andrea Hospital, University of Rome "Sapienza", Via Grottarossa, 1035, Rome (RM), Italy.
Knee Surgery Sports Traumatology Arthroscopy (impact factor: 2.21). 04/2012; DOI:10.1007/s00167-012-2005-7
Source: PubMed

ABSTRACT PURPOSE: The aim of this study was to evaluate the accuracy of conventional instrumentation for tibial resection in total knee arthroplasty (TKA) as assessed by a computer-based navigation system during each phase of the surgical procedure. The hypothesis is that conventional instrumentation fails to achieve optimal accuracy in final implant positioning, thus leading to surgical errors. METHODS: Forty primary TKAs were performed. The resection guide was placed using an extramedullary guide. Accurate guide positioning was assessed by the navigation system prior to the osteotomy. The alignment measurement was repeated after resection and after component implantation in order to quantify the deviation caused by the manual positioning of the prosthetic components. A deviation ≥2° was considered unsatisfactory. RESULTS: In the frontal plane, unsatisfactory results observed were as follows: 15 % with reference to manual positioning of the resection guide and 10 % with reference to definition of the resection plane with a tendency towards varus malalignment. In the sagittal plane, unsatisfactory results were as follows: 45 % with reference to manual positioning of the resection guide and 40 % with reference to definition of the resection plane with a trend of decreased tibial slope angle. The deviation between bone resection and subsequent implant placement was ≥2° in none of the cases. CONCLUSIONS: The study confirms the hypothesis that conventional instrumentation fails to achieve optimal accuracy in the positioning of the tibial component. During each phase of the surgical procedure, a tendency towards varus malalignment and a decreased tibial slope angle were observed. LEVELS OF EVIDENCE: II.

0 0
 · 
0 Bookmarks
 · 
26 Views

Keywords

Accurate guide positioning
 
alignment measurement
 
bone resection
 
component implantation
 
computer-based navigation system
 
decreased tibial slope angle
 
final implant positioning
 
frontal plane
 
manual positioning
 
navigation system
 
optimal accuracy
 
primary TKAs
 
resection plane
 
sagittal plane
 
subsequent implant placement
 
surgical errors
 
tibial resection
 
tibial slope angle
 
total knee arthroplasty
 
unsatisfactory results
 

R Iorio