Enhancing Impedance Imaging Through Multimodal Tomography

Inst. of Med. Eng., Graz Univ. of Technol., Graz, Austria
IEEE Transactions on Biomedical Engineering (impact factor: 2.28). 12/2011; DOI:10.1109/TBME.2011.2165714 pp.3215 - 3224
Source: IEEE Xplore

ABSTRACT Several noninvasive modalities including electrical impedance tomography (EIT), magnetic induction tomography (MIT), and induced-current EIT (ICEIT) have been developed for imaging the electrical conductivity distribution within a human body. Although these modalities differ in how the excitation and detection circuitry (electrodes or coils) are implemented, they share a number of common principles not only within the image reconstruction approaches but also with respect to the basic principle of generating a current density distribution inside a body and recording the resultant electric fields. In this paper, we are interested in comparing differences between these modalities and in theoretically understanding the compromises involved, despite the increased hardware cost and complexity that such a multimodal system brings along. To systematically assess the merits of combining data, we performed 3-D simulations for each modality and for the multimodal system by combining all available data. The normalized sensitivity matrices were computed for each modality based on the finite element method, and singular value decomposition was performed on the resultant matrices. We used both global and regional quality measures to evaluate and compare different modalities. This study has shown that the condition number of the sensitivity matrix obtained from the multimodal tomography with 16-electrode and 16-coil is much lower than the condition number produced in the conventional 16-channel EIT and MIT systems, and thus, produced promising results in terms of image stability. An improvement of about 20% in image resolution can be achieved considering feasible signal-to-noise ratio levels.

0 0
 · 
0 Bookmarks
 · 
24 Views

Keywords

condition number
 
conventional 16-channel EIT
 
current density distribution
 
detection circuitry
 
different modalities
 
electrical conductivity distribution
 
electrical impedance tomography
 
feasible signal-to-noise ratio levels
 
finite element method
 
image reconstruction approaches
 
image stability
 
induced-current EIT
 
magnetic induction tomography
 
MIT systems
 
multimodal system
 
noninvasive modalities
 
promising results
 
regional quality measures
 
resultant electric fields
 
theoretically understanding