Reproducibility of radiographic hip measurements in adults.

Service de radiologie, CHU la Cavale-Blanche, 29609 Brest, France.
Joint, bone, spine: revue du rhumatisme (Impact Factor: 2.25). 03/2012; DOI: 10.1016/j.jbspin.2012.02.002
Source: PubMed

ABSTRACT INTRODUCTION: Hip dysplasia may cause pain and premature hip osteoarthritis. Here, our objective was to assess the inter- and intraobserver reproducibility of radiographic hip parameter measurement in adults. METHODS: We used anteroposterior pelvic radiographs and false-profile lateral hip radiographs from 30 individuals (60 hips) enrolled in a prevalence study of hip osteoarthritis. For each hip, two independent observers recorded five parameters twice, at an interval of 1month. The five parameters were the vertical-center-edge angle (VCE), the anterior center-edge angle (vertical-center-anterior angle, VCA), the acetabular roof angle (HTE), the neck-shaft angle (CC'D), and acetabulum depth (AD). Reproducibility was assessed using Bland-Altman plots, intraclass correlation coefficients (ICCs), and kappa coefficients for the radiographic diagnosis of hip dysplasia using widely accepted cutoffs. RESULTS: Of the 60 hips, 51 were assessable. Intraobserver ICC values ranged from 0.72 to 0.94 and interobserver ICC values from 0.68 to 0.84. Kappa coefficients were between 0.60 and 1.00, except for the VCA angle (κ=0.41). CONCLUSION: In this study, reproducibility of the main radiographic hip parameters was good according to all evaluation methods used. However, CC'D and, to an even greater extent, the VCA angle seemed challenging to measure.

0 Bookmarks
 · 
169 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: BACKGROUND: Lateral center-edge angle (LCEA), originally described and validated on AP radiographs, has been used increasingly in CT-based studies, but it is unclear whether the measure is reliable and whether it correlates with that on AP radiographs. QUESTION/PURPOSES: We therefore determined: (1) the interobserver and intraobserver reliabilities of the LCEA measured on AP radiographs; (2) the interobserver and intraobserver reliabilities of the LCEA measured on CT scans; and (3) the intermodality correlation of the LCEA between CT and AP radiography. METHODS: We reviewed the AP radiographs and CT scans of 22 patients treated for slipped capital femoral epiphyses. CT scans were reoriented to a neutral pelvic tilt and inclination. Three evaluators measured the LCEA on the unaffected hip on the AP and CT coronal images that corresponded to the center of the acetabulum on the axial slice. RESULTS: We found an interobserver intraclass correlation (ICC) analysis of 0.84 for the AP radiographs and 0.88 for the CT scans. The intraobserver ICC for the AP radiographs was 0.96, and for the CT scans 0.98. The intermodality ICC for the CT scans and AP radiographs was 0.79, with a lower bound of 0.61 and an upper bound of 0.87. CONCLUSIONS: Our data suggest the LCEA measured on a CT scan is reliable and correlates with the LCEA on AP radiographs.
    Clinical Orthopaedics and Related Research 10/2012; · 2.79 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs.
    Skeletal Radiology 07/2014; · 1.74 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The aim of this study was to evaluate the limitations of the Tönnis angle as one of the most commonly used parameters in the diagnosis of acetabular dysplasia, and to explore the feasibility of the modified Tönnis angle in the diagnosis of acetabular dysplasia. A total of 224 patients (120 females and 104 males) with 448 hips, aged between 15 and 83 years (median, 45.0 years), were selected for the measurement of the center-edge (CE) and Tönnis angles. To evaluate the relative position of the medial edge of the acetabular sourcil, a new parameter, known as the center-medial-edge (CME) angle, was designed. As an improvement of the Tönnis angle, a new angle preliminarily termed the modified Tönnis angle was created. In addition, the degree of clarity of the medial edge of the acetabular sourcil on radiograph was evaluated, and the hips were divided into the clear-edge and blurred-edge groups. The hips belonging to the blurred-edge group could not be used for Tönnis angle measurements. All measurements were performed digitally using the tool of the picture-archiving communication system. Among the 448 acetabular sourcils, 142 had a blurred medial edge (31.7%). The mean value of the CME angle was 37.94°, with a range of 21.76-63.99°. The 95% prediction interval of the modified Tönnis angle was estimated to be -6.39 to 11.73°. The correlation coefficients were -0.838 between the CE and Tönnis angles, 0.889 between the Tönnis and modified Tönnis angles and -0.905 between the CE and modified Tönnis angles. In conclusion, the modified Tönnis angle can substitute for the Tönnis angle without joint space narrowing and subluxation of the hip, particularly when the Tönnis angle cannot be measured due to a blurred medial edge of the acetabular sourcil on pelvic radiograph.
    Experimental and therapeutic medicine 12/2014; 8(6):1934-1938. · 0.34 Impact Factor