Parametric imaging of the local attenuation coefficient in human axillary lymph nodes assessed using optical coherence tomography

Biomedical Optics Express (Impact Factor: 3.5). 02/2012; 3(2):366-79. DOI: 10.1364/BOE.3.000366
Source: PubMed

ABSTRACT We report the use of optical coherence tomography (OCT) to determine spatially localized optical attenuation coefficients of human axillary lymph nodes and their use to generate parametric images of lymphoid tissue. 3D-OCT images were obtained from excised lymph nodes and optical attenuation coefficients were extracted assuming a single scattering model of OCT. We present the measured attenuation coefficients for several tissue regions in benign and reactive lymph nodes, as identified by histopathology. We show parametric images of the measured attenuation coefficients as well as segmented images of tissue type based on thresholding of the attenuation coefficient values. Comparison to histology demonstrates the enhancement of contrast in parametric images relative to OCT images. This enhancement is a step towards the use of OCT for in situ assessment of lymph nodes.

1 Follower
 · 
167 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Objectives: Optical Coherence Tomography (OCT) has been proposed as a high resolution image modality to guide transbronchial biopsies. In this study we address the question, whether individual A-scans obtained in needle direction can contribute to the identification of pulmonary nodules. Methods: OCT A-scans from freshly resected human lung tissue specimen were recorded through a customized needle with an embedded optical fiber. Bidirectional Long Short Term Memory networks (BLSTMs) were trained on randomly distributed training and test sets of the acquired A-scans. Patient specific training and different pre-processing steps were evaluated. Results: Classification rates from 67.5% up to 76% were archived for different training scenarios. Sensitivity and specificity were highest for a patient specific training with 0.87 and 0.85. Low pass filtering decreased the accuracy from 73.2% on a reference distribution to 62.2% for higher cutoff frequencies and to 56% for lower cutoff frequencies. Conclusion: The results indicate that a grey value based classification is feasible and may provide additional information for diagnosis and navigation. Furthermore, the experiments show patient specific signal properties and indicate that the lower and upper parts of the frequency spectrum contribute to the classification.
    Methods of Information in Medicine 07/2014; 53(4). DOI:10.3414/ME13-01-0135 · 1.08 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Image formation in optical coherence elastography (OCE) results from a combination of two processes: the mechanical deformation imparted to the sample and the detection of the resulting displacement using optical coherence tomography (OCT). We present a multiphysics model of these processes, validated by simulating strain elastograms acquired using phase-sensitive compression OCE, and demonstrating close correspondence with experimental results. Using the model, we present evidence that the approximation commonly used to infer sample displacement in phase-sensitive OCE is invalidated for smaller deformations than has been previously considered, significantly affecting the measurement precision, as quantified by the displacement sensitivity and the elastogram signal-to-noise ratio. We show how the precision of OCE is affected not only by OCT shot-noise, as is usually considered, but additionally by phase decorrelation due to the sample deformation. This multiphysics model provides a general framework that could be used to compare and contrast different OCE techniques.
    Biomedical Optics Express 09/2014; 5(9). DOI:10.1364/BOE.5.002913 · 3.50 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: We present the assessment of ex vivo mouse muscle tissue by quantitative parametric imaging of the near-infrared attenuation coefficient µt using optical coherence tomography. The resulting values of the local total attenuation coefficient µt (mean ± standard error) from necrotic lesions in the dystrophic skeletal muscle tissue of mdx mice are higher (9.6 ± 0.3 mm(-1)) than regions from the same tissue containing only necrotic myofibers (7.0 ± 0.6 mm(-1)), and significantly higher than values from intact myofibers, whether from an adjacent region of the same sample (4.8 ± 0.3 mm(-1)) or from healthy tissue of the wild-type C57 mouse (3.9 ± 0.2 mm(-1)) used as a control. Our results suggest that the attenuation coefficient could be used as a quantitative means to identify necrotic lesions and assess skeletal muscle tissue in mouse models of human Duchenne muscular dystrophy.
    Biomedical Optics Express 04/2014; 5(4):1217-32. DOI:10.1364/BOE.5.001217 · 3.50 Impact Factor

Full-text (3 Sources)

Download
29 Downloads
Available from
May 23, 2014