Article

Electrochemical disinfection: an efficacy treatment to inactivate E. coli O157:H7 in process wash water containing organic matter. Food Microbiology, 30, 146-156

Research Group on Quality, Safety and Bioactivity of Plant Foods, Department of Food Science and Technology, CEBAS-CSIC, P.O. Box 164, Espinardo, Murcia, E-30100, Spain.
Food Microbiology (Impact Factor: 3.37). 05/2012; 30(1):146-56. DOI: 10.1016/j.fm.2011.09.010
Source: PubMed

ABSTRACT The efficacy of an electrochemical treatment in water disinfection, using boron-doped diamond electrodes, was studied and its suitability for the fresh-cut produce industry analyzed. Tap water (TW), and tap water supplemented with NaCl (NaClW) containing different levels of organic matter (Chemical Oxygen Demand (COD) around 60, 300, 550 ± 50 and 750 ± 50 mg/L) obtained from lettuce, were inoculated with a cocktail of Escherichia coli O157:H7 at 10⁵ cfu/mL. Changes in levels of E. coli O157:H7, free, combined and total chlorine, pH, oxidation-reduction potential, COD and temperature were monitored during the treatments. In NaClW, free chlorine was produced more rapidly than in TW and, as a consequence, reductions of 5 log units of E. coli O157:H7 were achieved faster (0.17, 4, 15 and 24 min for water with 60, 300, 500 and 750 mg/L of COD, respectively) than in TW alone (0.9, 25, 60 min and 90 min for water with 60, 300, 600 and 800 mg/L of COD, respectively). Nonetheless, the equipment showed potential for water disinfection and organic matter reduction even without adding NaCl. Additionally, different mathematical models were assessed to account for microbial inactivation curves obtained from the electrochemical treatments.

Download full-text

Full-text

Available from: Ana Allende, Aug 29, 2015
0 Followers
 · 
273 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: This work assesses the disinfection for reuse of treated urban wastewaters using electrochemical-oxidation with conductive-diamond anodes, without adding any external chemical reagent. Three actual effluents of municipal wastewater treatment plants (sample collected from the secondary clarifiers) have been treated using this technology, in every case, a complete removal of Escherichia coli have been achieved. In addition, it has been found that working within the range of current densities proposed in this work (1.3–13.0 A m−2), this technology does not form any hazardous by-products (neither perchlorates nor halo-compounds), even at trace level. Combined effects of chloramines and hypochlorite seem to be the main mechanisms to explain disinfection. The primary disinfectant produced in every electrolyses depends on the current density, and on the concentration of both: chlorides and non-oxidized nitrogen, present in the raw treated wastewater. Power consumption as low as 0.2 kW h m−3 is enough to assure the complete disinfection of a particular treated wastewater. The lower the applied current density, the lower the energy required to get the disinfection of the treated wastewater.
    Chemical Engineering Journal 11/2012; s 211–212:463–469. DOI:10.1016/j.cej.2012.09.071 · 4.32 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The anti-norovirus (anti-NoV) effect of grape seed extract (GSE) was examined by plaque assay for murine norovirus 1 (MNV-1), cell-binding reverse transcription-PCR for human NoV GII.4, and saliva-binding enzyme-linked immunosorbent assay for human NoV GII.4 P particles, with or without the presence of interfering substances (dried milk and lettuce extract). GSE at 0.2 and 2 mg/ml was shown to reduce the infectivity of MNV-1 (>3-log PFU/ml) and the specific binding ability of NoV GII.4 to Caco-2 cells (>1-log genomic copies/ml), as well as of its P particles to salivary human histo-blood group antigen receptors (optical density at 450 nm of >0.8). These effects were decreased as increasing concentrations of dried milk (0.02 and 0.2%) or lettuce extract were added. Under an electron microscope, human NoV GII.4 virus-like particles showed inflation and deformation after treatment with GSE. Under conditions that simulated applications in the food industry, the anti-NoV effect of GSE using MNV-1 as a target organism was shown to be limited in surface disinfection (<1-log PFU/ml, analyzed in accordance with EN 13697:2001). However, a 1.5- to 2-log PFU/ml reduction in MNV-1 infectivity was noted when 2 mg of GSE/ml was used to sanitize water in the washing bath of fresh-cut lettuce, and this occurred regardless of the chemical oxygen demand (0 to 1,500 mg/ml) of the processing water.
    Applied and Environmental Microbiology 08/2012; 78(21):7572-8. DOI:10.1128/AEM.01987-12 · 3.95 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The effect of operating conditions (current density, recirculation flow rate and electrode doping level) on the efficacy of boron-doped diamond (BDD) electrodes to inactivate microorganisms and decrease chemical oxygen demand (COD) was studied in lettuce process wash water with a COD of 725 mg/L and inoculated with a 5-strain cocktail of Escherichia coli O157:H7. Changes in pathogen population, COD, pH, temperature, redox potential, and free and total chlorine were monitored in process wash water during treatments. Considering the specific characteristics of the washing step included in the fresh-cut processing, the disinfection of process wash water should be of fast action. A biphasic with a shoulder model was used to estimate shoulder length (Sl), log-linear inactivation rates (kmax1,kmax2), lowest population (Nf) and highest log reduction (HLR). Current density clearly influenced Sl, and kmax2; recirculation flow rate influenced Sl, kmax1,kmax2 and COD depletion; and doping level influenced Nf. No relationship was observed between inactivation parameters and chlorine concentration. Conditions including high current density (180 mA/cm2), high flow rate (750 l/h) and high doping level (8 000 μmol/mol) seems to provide a disinfection efficiency suitable to decrease the chance of bacterial cross contamination in the fresh-cut industries while saving on water consumption and decreasing the amount of wastewater effluents.
    Food Control 01/2013; 29(1):42–48. DOI:10.1016/j.foodcont.2012.05.052 · 2.82 Impact Factor
Show more