Article

Application of LC-high-resolution MS with “intelligent” data mining tools for screening reactive Drug metabolites

Department of Drug Metabolism and Pharmacokinetics, Genentech, Inc., South San Francisco, CA, USA.
Bioanalysis (Impact Factor: 3.03). 03/2012; 4(5):501-10. DOI: 10.4155/bio.12.5
Source: PubMed

ABSTRACT Biotransformation of chemically stable compounds to reactive metabolites that can bind covalently to macromolecules (such as proteins and DNA) is considered an undesirable property of drug candidates. Due to the possible link, which has not yet been conclusively demonstrated, between reactive metabolites and adverse drug reactions, screening for metabolic activation of lead compounds through in vitro chemical trapping experiments has become an integral part of the drug discovery process in many laboratories. In this review, we provide an overview of the recent advances in the application of high-resolution MS. These advances facilitated the development of accurate-mass-based data mining tools for high-throughput screening of reactive drug metabolites in drug discovery.

3 Followers
 · 
145 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: This chapter contains sections titled: Introduction In Vitro Trapping of Reactive Metabolites Traditional Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS) Approaches for Reactive Metabolite Screening HRMS Accurate Mass-Based Data Mining Tools for Screening Reactive Metabolites Quantitation of Reactive Metabolite Formation Challenges and Future Perspectives References
    Mass Spectrometry for Drug Discovery and Drug Development, 01/2013: pages 339-355; , ISBN: 9780470942383
  • [Show abstract] [Hide abstract]
    ABSTRACT: This chapter summarizes the current thinking and practices in the pharmaceutical industry in support of metabolites in safety testing (MIST) related activities. It compares two of several options available for conducting absorption, distribution, metabolism, and excretion (ADME) studies using radiolabled materials. In the first option, radiolabeled studies are not scheduled until after the interpretation of human pharmacokinetics (PK) and metabolism in the first-in-human (FIH) studies, while in the second option, preclinical radiolabeled ADME studies are initiated before the completion of the FIH studies. The chapter discusses some of the liquid chromatography—mass spectrometry (LC-MS) methods available for detecting and characterizing metabolites. Bioanalytical assays, used for detection, characterization and exposure estimation of metabolites, are tiered into (i) metabolite profiling, (ii) standard free quantification/ response factor determination, (iii) qualified assays, and (vi) validated assays.
    Handbook of LC-MS Bioanalysis, 08/2013: pages 71-82; , ISBN: 9781118159248
  • [Show abstract] [Hide abstract]
    ABSTRACT: Sensitive and selective liquid chromatography-mass spectrometry (LC-MS) analysis is a powerful and essential tool for metabolite identification in drug discovery and development. An MS(2) (or tandem, MS/MS) mass spectrum is acquired from the fragmentation of a precursor ion by multiple methods including information-dependent acquisition (IDA), SWATH (sequential window acquisition of all theoretical fragment-ion spectra), and MS(All) (also called MS(E)) techniques. We compared these three techniques in their capabilities to produce comprehensive MS(2) data by assessing both metabolite MS(2) acquisition hit rate and the quality of MS(2) spectra. Rat liver microsomal incubations from eight test compounds were analyzed with four methods (IDA, MMDF (multiple mass defect filters)-IDA, SWATH, or MS(All)) using an ultrahigh-performance liquid chromatography-qudrupole time-of-flight mass spectrometry (UHPLC-Q-TOF MS) platform. A combined total of 227 drug-related materials (DRM) were detected from all eight test article incubations, and among those, 5% and 4% of DRM were not triggered for MS(2) acquisition with IDA and MMDF-IDA methods, respectively. When the same samples were spiked to an equal volume of blank rat urine (urine sample), the DRM without MS(2) acquisition increased to 29% and 18%, correspondingly. In contrast, 100% of DRM in both matrixes were subjected to MS(2) acquisition with either the SWATH or MS(All) method. However, the quality of the acquired MS(2) spectra decreased in the order of IDA, SWATH, and MS(All) methods. An average of 10, 9, and 6 out of 10 most abundant ions in MS(2) spectra were the real product ions of DRM detected in microsomal samples from IDA, SWATH, and MS(All) methods, respectively. The corresponding numbers declined to 9, 6, and 3 in the urine samples. Overall, IDA-based methods acquired qualitatively better MS(2) spectra but with a lower MS(2) acquisition hit rate than the other two methods. SWATH outperformed the MS(All) method given its better quality of MS(2) spectra with an identical MS(2) acquisition hit rate.
    Analytical Chemistry 01/2014; 86(2). DOI:10.1021/ac403385y · 5.83 Impact Factor
Show more