Quantitative aspects of transduction in an electroreceptor organ studied by means of experimental manipulation of the interspike interval.

P F Teunis, F. Bretschneider, C van Groeningen, R.C. Peters, J J Bedaux

Ruhr Universität Bochum, Fachbereich Biologie, F.R.G.

Journal Article: Neuroscience (impact factor: 3.29). 02/1991; 42(1):283-9.

Abstract

The interspike interval histogram of spontaneously firing electroreceptor organs of freshwater catfish (Ictalurus nebulosus LeS.) fits well with the probability density function of a gamma distribution. The shape parameter r of this probability density function can be used as a measure for the firing threshold of the spike generator, and the scale parameter lambda provides a measure for the input rate of synaptic quanta. Here, we have studied the physiological meaning of the two parameters of the fitted gamma probability density function by manipulating the mean firing rate. This was done in two ways: "frequency clamp" stimulation and a change in temperature. Frequency clamp stimulation, compensating for adaptation of the response, keeps the afferent firing rate at a fixed value for a limited period. We show that within such a period not only the mean spike rate remains constant, but these spike trains can be regarded as renewal series: the spike generator is functionally uncoupled from the frequency-dependent parts of the transduction path. Concerning the gamma parameters, two types of responses are found: at strong excitation lambda increases, r does not change; with small stimuli r is inversely proportional to the stimulus strength, lambda remains unchanged. This is difficult to explain when stimulus transduction acts via the synaptic input rate only. Stimulation seems to influence the firing threshold of the spike generator directly. At strong inhibition a regular firing pattern suddenly takes over; the major part of the variability suddenly disappears from the spike train. A change in temperature causes a shift in lambda (Q10 approximately 2.3), but not in r. This points to a temperature effect on the input rate only.

Source: PubMed

Comments on this publication

ResearchGate members can add comments. Sign up now and post your comment!

Similar publications

Science & Research Jobs

Keywords

electroreceptor organs
 
firing threshold
 
fitted gamma probability density function
 
Frequency clamp stimulation
 
freshwater catfish
 
gamma distribution
 
Ictalurus nebulosus LeS
 
interspike interval histogram
 
limited period
 
mean spike rate
 
probability density function
 
scale parameter lambda
 
shape parameter r
 
small stimuli r
 
spike train
 
stimulus transduction acts
 
strong excitation lambda increases
 
synaptic input rate
 
temperature effect
 
transduction path