Article

Evaluation of an immunoassay for direct detection of Escherichia coli O157 in stool specimens.

Department of Laboratory Medicine, Mayo Clinic, Rochester, Minnesota 55905.
Journal of Clinical Microbiology (Impact Factor: 4.07). 02/1995; 33(1):222-4.
Source: PubMed

ABSTRACT An enzyme-linked immunosorbent assay (ELISA) produced by LMD Laboratories, Inc., Carlsbad, Calif., was compared with culture for the detection of Escherichia coli O157. Nine of 185 stool specimens evaluated had positive results by the LMD E. coli O157 ELISA and grew E. coli O157 on culture; 174 had negative by LMD E. coli O157 ELISA results and did not grow E. coli O157 on culture. Of 174 specimens negative by LMD E. coli O157 ELISA, 117 specimens grew other enteric pathogens: Campylobacter spp. (46 isolates), Salmonella spp. (43 isolates), Yersinia spp. (20 isolates), and Shigella spp. (8 isolates). There were two indeterminant results by the LMD E. coli O157 ELISA. One stool specimen did not grow other enteric pathogens on culture, and one grew a Campylobacter sp. on culture. Both had negative LMD E. coli O157 ELISA results upon repeat testing. The LMD E. coli O157 ELISA is an accurate, easy-to-read screening method for the detection of E. coli O157 in fecal specimens.

0 Bookmarks
 · 
35 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: We present a label-free, optical nano-biosensor based on the Localized Surface Plasmon Resonance (LSPR) that is observed at the metal-dielectric interface of silver nano-disk arrays located periodically on a sapphire substrate by Electron-Beam Lithography (EBL). The nano-disk array was designed by finite-difference and time-domain (FDTD) algorithm-based simulations. Refractive index sensitivity was calculated experimentally as 221-354 nm/RIU for different sized arrays. The sensing mechanism was first tested with a biotin-avidin pair, and then a preliminary trial for sensing heat-killed Escherichia coli (E. coli) O157:H7 bacteria was done. Although the study is at an early stage, the results indicate that such a plasmonic structure can be applied to bio-sensing applications and then extended to the detection of specific bacteria species as a fast and low cost alternative.
    Optics Express 01/2012; 20(3):2587-97. · 3.55 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Rapid identification of Escherichia coli O157:H7 is important for patient management and for prompt epidemiological investigations. We evaluated one in-house method and three commercially available kits for their ability to extract E. coli O157:H7 DNA directly from stool specimens for PCR. Of the 153 stool specimens tested, 107 were culture positive and 46 were culture negative. The sensitivities and specificities of the in-house enrichment method, IsoQuick kit, NucliSens kit, and QIAamp kit were comparable, as follows: 83 and 98%, 85 and 100%, 74 and 98%, and 86 and 100%, respectively. False-negative PCR results may be due to the presence of either inherent inhibitors or small numbers of organisms. The presence of large amounts of bacteria relative to the amount of the E. coli O157:H7 target may result in the lower sensitivities of the assays. All commercial kits were rapid and easy to use, although DNA extracted with the QIAamp kit did not require further dilution of the DNA template prior to PCR.
    Journal of Clinical Microbiology 12/2000; 38(11):4108-13. · 4.07 Impact Factor
  • Source
    Journal of Clinical Microbiology 09/2002; 40(8):2711-5. · 4.07 Impact Factor

Full-text

View
0 Downloads
Available from